39E Operating instructions 

 

Page

 

4 / 8

 

──────────────────────────────────────────────────────────────

 

SW V1.01 

11.09.2005  

                       La Gard Latin America - 741 Shotgun Rd. – Sunrise Florida – 33351 – USA 
                      Tel. +1 954 476 5574 – Fax. + 7 954 476 5576 – Email: info@lagardlat.com 

 

 

Pre-setup mode 

 

After factory reset lock enters pre-setup mode. Communication with lock using serial interface on TAG reader is 
possible to test and setup the lock.  

Into this mode, pressing key '1' activates solenoid, silent alarm and test remote input. Key '0' send power-upprompt 
(request for PC Setup software). Other keys beep once. 

Pre-setup mode cancelled by keeping down '0' key until double beep, and entering any valid code.  

 

Special procedures 

 

Setup process, to do list 

 

The following steps are necessary to setup the lock from the ground:  

 

Factory reset. Configuration is reset to default.  

 

Select code length (manager function #8). Choose how many digits for manager and users codes. Select 
standard mode (without additional features). 

 

Install users (manager function #1). Install all users you need with default codes. Deleted (or never installed) 
users will not be available after manager changes his code.  

 

Select additional features (manager function #8). Enter ‘0’ as code length to not modify it. Choose optional 
features.  

 

Freeze configuration (manager function #0). Manager changes his code to freeze configuration. 

Lock is now fully operational. 

Note that PC Setup software is able to set whole configuration using serial interface. 

 

Factory reset procedure 

Remove battery.  

Hold down key ‘0’ during 10s to discharge all internal capacitors.  

Connect Reset Box to alarm box connector.  

Put the battery back in place, factory reset is completed.  

Disconnect Reset Box.  

Lock configuration is: 6 digits code, only manager code exists, set to all ‘5’. Audit file not cleared.  

Lock will be operational as soon as manager changes his code. 

Summary of Contents for 39E

Page 1: ..._______________________________________________3 Lock states _____________________________________________________________4 Pre setup mode___________________________________________________________ 4...

Page 2: ...specifications are 1 200bauds no parity 8 data bits 1 stop bit PC and other serial devices may be connected to setup the lock and the get audit file Alarm box connector Standard 4 wires connector to...

Page 3: ...lay enabled LED flashes at two seconds intervals Open window is indicated by LED then buzzer at 1 seconds intervals alternately once LED once beep Battery low warning If battery low 6V during solenoid...

Page 4: ...anager function 8 Choose how many digits for manager and users codes Select standard mode without additional features Install users manager function 1 Install all users you need with default codes Del...

Page 5: ...t digit until double beep Enter special function number 0 9 Double beep if valid triple beep if not Open procedures To open Standard mode Enter code If time delay enabled wait open window Enter code a...

Page 6: ...if user blocked Enter new code Enter code again to confirm Double beep if correct triple beep if confirmation error Notes Manager only When enrolled he can install only users that were not blocked by...

Page 7: ...mission LED is still on a during search of audit beginning into memory Notes Manager only Audit file is automatically printed at each power up except in pre setup mode Audit printing may be stopped by...

Page 8: ...y and only if not enrolled his code was never changed Manager cannot choose dual code mode if no user installed nor active If code length is modified users codes are deleted and manager code is set to...

Reviews: