General procedures 

 

To enter manager or user code 

 

Enter code. Double beep if valid, triple beep if wrong code.  

To enter special function (manager or user) 

 

Enter code, holding down last digit. Double beep. Keep holding down last digit until double beep. Enter special 
function number (0 - 9). Double beep if valid, triple beep if not.  

 

Open procedures 

 

To open (Standard mode) 

 

Enter code. 

If time delay enabled wait open window. Enter code again. 

Solenoid / motor is activated. 

 

To open (Time Delay override mode) 

 

Enter user #9 code. Solenoid / motor is activated. 

Note

 

If dual code mode enabled, enter first manager or user code, then override code.  

To open (Dual code mode) 

 

Enter first code. 

Enter second code. 

If time delay enabled, first code will start time delay. During open window, enter both codes to activate solenoid / 

motor. 

Solenoid / motor is activated. 

Summary of Contents for 39E

Page 1: ..._______________________________________________3 Lock states _____________________________________________________________4 Pre setup mode___________________________________________________________ 4...

Page 2: ...specifications are 1 200bauds no parity 8 data bits 1 stop bit PC and other serial devices may be connected to setup the lock and the get audit file Alarm box connector Standard 4 wires connector to...

Page 3: ...lay enabled LED flashes at two seconds intervals Open window is indicated by LED then buzzer at 1 seconds intervals alternately once LED once beep Battery low warning If battery low 6V during solenoid...

Page 4: ...anager function 8 Choose how many digits for manager and users codes Select standard mode without additional features Install users manager function 1 Install all users you need with default codes Del...

Page 5: ...t digit until double beep Enter special function number 0 9 Double beep if valid triple beep if not Open procedures To open Standard mode Enter code If time delay enabled wait open window Enter code a...

Page 6: ...if user blocked Enter new code Enter code again to confirm Double beep if correct triple beep if confirmation error Notes Manager only When enrolled he can install only users that were not blocked by...

Page 7: ...mission LED is still on a during search of audit beginning into memory Notes Manager only Audit file is automatically printed at each power up except in pre setup mode Audit printing may be stopped by...

Page 8: ...y and only if not enrolled his code was never changed Manager cannot choose dual code mode if no user installed nor active If code length is modified users codes are deleted and manager code is set to...

Reviews: