39E Operating instructions
Page
6 / 8
────────────────────────────────────────────────────────────
──
SW V1.01
11.09.2005
La Gard Latin America - 741 Shotgun Rd. – Sunrise Florida – 33351 – USA
Tel. +1 954 476 5574 – Fax. + 7 954 476 5576 – Email: info@lagardlat.com
Special functions
To change code
(special function #0)
Enter special function #0.
Enter new code. Enter code again to confirm. Double beep if correct, triple beep if confirmation error.
Notes:
•
To be compatible with older products, alternative way to change code is to enter an all ‘0’ code. Then
enter old code. Enter new code. Enter code again to confirm. Double beep if correct, triple beep if
confirmation error.
•
When manager changes hits code, this will freeze configuration (function #8 no more available).
Alsoblocked users at that time can not more be installed (no more available to manager).
To install or reinstate user
(special function #1)
Enter special function #1.
Enter user ID (1 - 9). Single beep if user exists; user is now enabled. Double beep if user does not exist. Triple
beep if user blocked. Enter new code. Enter code again to confirm. Double beep if correct, triple beep if
confirmation error.
Notes:
•
Manager only. When enrolled, he can install only users that were not blocked by PC Setup software or by
himself.
•
Manager can install user #9 only if no time delay or during open window or if time delay override input
active.
If dual code mode enabled, manager code has to be entered after an user code to access special function.
To disable user
(special function #2)
Enter special function #2.
Enter user ID. Single beep if user exists, he is now disabled. Triple beep if user does not exist.
Notes:
•
Manager
only.
•
If dual code mode enabled: manager code has to be entered after an user code to access special function.
Manager can not disable user that allows him to access special function.
To delete user
(special function #3)
Enter special function #3.
Enter user ID. Single beep if user exists, he is now deleted. Triple beep if user does not exist.
Notes:
•
Manager
only.
•
If dual code mode enabled: manager code has to be entered after an user code to access special function.
Manager can not delete user that allows him to access special function.