39E Operating instructions
Page
7 / 8
────────────────────────────────────────────────────────────
──
SW V1.01
11.09.2005
La Gard Latin America - 741 Shotgun Rd. – Sunrise Florida – 33351 – USA
Tel. +1 954 476 5574 – Fax. + 7 954 476 5576 – Email: info@lagardlat.com
To get audit file (special function #7)
Enter special function #7, but before pressing on ‘7’, connect serial adapter to TAG reader, and start acquisitionon
connected device.
Audit file is transmitted to serial interface.
After transmission, LED is still on a during search of audit beginning into memory.
Notes:
•
Manager
only.
•
Audit file is automatically printed at each power-up (except in pre-setup mode).
•
Audit printing may be stopped by sending a break signal to lock (or keeping down ‘0’ key).
•
Audit file can not be cleared. When memory is full, older events are replaced by newer.
To check user status (special function #7b)
Enter special function #7, holding down function number until double beep.
By pressing user ID, you get his status: 1 beep = active, 2 = disabled, 3 = does not exist, long = blocked, not
available.
Enter ‘0’ to exit function.
Notes
:
•
Manager only.