To get audit file (special function #7) 

 

Enter special function #7, but before pressing on ‘7’, connect serial adapter to TAG reader, and start acquisitionon 

connected device. 

Audit file is transmitted to serial interface. 

After transmission, LED is still on a during search of audit beginning into memory. 

Notes: 

 

 Manager 

only. 

 

 

Audit file is automatically printed at each power-up (except in pre-setup mode).  

 

Audit printing may be stopped by sending a break signal to lock (or keeping down ‘0’ key).  

 

Audit file can not be cleared. When memory is full, older events are replaced by newer. 
 
 

To check user status (special function #7b) 

 

Enter special function #7, holding down function number until double beep. 

By pressing user ID, you get his status: 1 beep = active, 2 = disabled, 3 = does not exist, long = blocked, not 

available. 

Enter ‘0’ to exit function. 

Notes

 Manager only.  

Summary of Contents for 39E

Page 1: ..._______________________________________________3 Lock states _____________________________________________________________4 Pre setup mode___________________________________________________________ 4...

Page 2: ...specifications are 1 200bauds no parity 8 data bits 1 stop bit PC and other serial devices may be connected to setup the lock and the get audit file Alarm box connector Standard 4 wires connector to...

Page 3: ...lay enabled LED flashes at two seconds intervals Open window is indicated by LED then buzzer at 1 seconds intervals alternately once LED once beep Battery low warning If battery low 6V during solenoid...

Page 4: ...anager function 8 Choose how many digits for manager and users codes Select standard mode without additional features Install users manager function 1 Install all users you need with default codes Del...

Page 5: ...t digit until double beep Enter special function number 0 9 Double beep if valid triple beep if not Open procedures To open Standard mode Enter code If time delay enabled wait open window Enter code a...

Page 6: ...if user blocked Enter new code Enter code again to confirm Double beep if correct triple beep if confirmation error Notes Manager only When enrolled he can install only users that were not blocked by...

Page 7: ...mission LED is still on a during search of audit beginning into memory Notes Manager only Audit file is automatically printed at each power up except in pre setup mode Audit printing may be stopped by...

Page 8: ...y and only if not enrolled his code was never changed Manager cannot choose dual code mode if no user installed nor active If code length is modified users codes are deleted and manager code is set to...

Reviews: