(P/N) 742.049 Rev A 06/10 • © copyright 2010 

 

 

Kaba Mas LLC

page 1 of 13

AuditGard locks are shipped from LA GARD in Factory Default 
state without Users or features enabled. 

Factory Default:

 The Lock must be in the Factory Default state 

to be programmed by the PC software. 
Factory mode functions as follows: 
•  1 key – When pressed, will open the Lock. 
•  0 key – When pressed, prompts the AuditGard Setup software 
  to send the configuration settings to the Lock. 
•  All other keys perform no function. 

Setup:

 AuditGard locks must be programmed using the 

AuditGard Setup Software. 
Once programmed the Master and Manager Combinations are 
enabled, and MUST be changed to activate the Lock. 

Active:

 The Master must be changed before any Master 

commands are available. The Manager combination must be 
changed before any Manager commands are available. 

PROGRAMMABLE LOCK FEATURES 

MODES

 

(Multiple Modes may be selected.)

• 

Silent Alarm

 

(Alarm Box Required) 

  If enabled, this option will send a signal to an outside alarm 
  system through the LA GARD Alarm Box. 

•  Dual Mode

  If enabled, two combinations will be required to operate 
  the Lock.
  The Manager and one additional User must be active.

•  Time Delay Override

  If enabled, User 9 can override delay period.
  User 9 must be active. 

EXTERNAL SIGNALS

 

(Alarm Box Required. Only one External 

Signal type may be selected.)

 

An external input signal to the Alarm Box will either Disable 
Opening Only or Disable All Access depending on the selection 
programmed for External Signals. 
•  External Signal disables Lock opening with valid combination. 
• 

OR

 External Signal disables Lock opening with valid 

combination and all Lock commands.

TIME DELAY  

•  Delay Period 1 - 99 minutes 
•  Open Period 1 - 19 minutes 

NOTE: 

If the Time Delay On is not selected, then this feature is 

inactive. This feature may be enabled later. (Refer to Manager 
Instructions 759.128.)

COMBINATION LENGTH 

A combination length from six (6) to nine (9) digits may 
be selected.

NOTE: 

To maintain the VdS Class 2 and EN 1300 Class B 

certification when the duress alarm feature is used, a combination 
length of 7 digits or longer must be selected.

LOCK USERS 
Master

 

• 

Cannot

 open Lock 

•  Change Combination (Master combination is always 
  eight digits) 
•  Audit Lock 
•  Initiate Lock Reset 
•  If selected, Enable/Disable Manager 
•  If selected, Delete Manager

Manager (ID# 1)

•  Open Lock 
•  Change Combination 
•  Enable/Disable Users 
•  Delete Users 
•  Set Time Delay Values 
•  Audit Lock 

Users (ID# 2-9)

•  Open Lock 
•  Change Combination

STANDARD LOCK FEATURES 

Wrong Try Penalty  

•  Entry of four (4) consecutive invalid combinations initiates a five 
  (5) minute delay penalty. 
  Lock responses during the penalty period are as follows:
    -  The LED will flash every ten (10) seconds. 
    -  If any key is pressed, the Lock will flash the LED and beep 
      three times.
•  Once the penalty period has ended, two (2) consecutive invalid 
  combinations will initiate another five (5) minute penalty period. 

Low Battery Warning 

•  Repeated audio/visual signals (LED flashes/beeps) during Lock 
  opening indicate the battery is low and should be 
  replaced immediately.
•  If the battery level becomes too low to safely operate the Lock, 
  pressing any key will initiate the low battery warning. 
  The battery must be replaced before the Lock will operate. 

Audit Records 

•  Lock records the last 512 events in non-volatile memory. 
•  Audit file cannot be deleted from the Lock. 
•  Either the Master or the Manager can audit the Lock.
•  AuditGard auditing software and an Interface Adapter are 
  required to retrieve a Lock audit.

AUDITGARD

LGA Electronic Combination Lock

setup instructions

Summary of Contents for AuditGard

Page 1: ...minutes Open Period 1 19 minutes Note If the Time Delay On is not selected then this feature is inactive This feature may be enabled later Refer to Manager Instructions 759 128 COMBINATION LENGTH A c...

Page 2: ...ken Note Locks must be factory programmed with this feature enabled The eKEY is a 48 bit encrypted unique serial number dual token device To open the Lock enter combination insert and quickly remove t...

Page 3: ...re two types of programming cables used with the AuditGard P N 42145 or P N 43087 depending upon which Entry Device is used CONFIGURE LOCK SETTINGS Start the Setup Program Select the AG Setup icon fro...

Page 4: ...rts COM LPT The list of communication and printer ports currently identified in the PC system will be displayed e Plug the USB or Serial Interface Adapter into an available USB port on the PC If using...

Page 5: ...elect Mode s Select by placing a check mark in the desired operational Mode External Signals and Time Delay Multiple modes can be selected Silent Alarm If selected a LA GARD alarm box will be required...

Page 6: ...049 Rev A 06 10 copyright 2010 Kaba Mas LLC page 6 of 13 Time Delay Override If selected User 9 must be installed to use this option If selected the software will automatically install User 9 Figure 6...

Page 7: ...to the other option Figure 8 Select Time Delay The Delay and Open Periods may be set up in this window Enable feature by placing a check mark in the Time Delay On box Then enter the desired time perio...

Page 8: ...ock Reset and if selected Enable Disable Disable the Manager Figure 11 The Master CANNOT open the Lock Refer to Master Instructions 788 0310 Note If the default combination is change using the softwar...

Page 9: ...13 Figure 13 5 Click on the Transmit button in the software Figure 14 6 Press the 0 key on the keypad to begin transmitting the configurations to the lock Figures 15 16 17 If the COM port has been in...

Page 10: ...iguration Once the setup configuration has been completed you may name and save the setup file xml for future use 1 Click the Save button or on the Files tab at the top of the program and select Save...

Page 11: ...onfiguration file has been saved it may be used to program a Lock by using the Load function of the AuditGard Setup software 1 Click the Load button or select Load from the File menu on the Menu bar F...

Page 12: ...efault 1 2 3 4 5 6 2 Open the Lock within four 4 seconds To complete the activation and add User s combinations the Manager combination MUST be changed CHANGE MANAGER COMBINATION 1 Enter the Manager c...

Page 13: ...f the lock does not open disconnect the Reset Box and repeat steps 2 and 3 5 Disconnect Reset Box The Lock is now in Factory default and can be reprogrammed using AuditGard Setup Software SOFTWARE RES...

Reviews: