LOCK OPERATING CONVENTIONS 

Without eKEY 

•  If a mistake is made while entering keystrokes, wait thirty (30) seconds and repeat operation. 
•  To access lock commands, enter combination and hold down the last digit until Lock double signals and the LED stays on. 
•  In Dual Mode, two combinations are required to operate the Lock. 

NOTE: 

In Dual Mode, a valid User combination must be entered first, followed by the Manager combination, to access the 

following Manager Commands: 1, 2, 3, 7 and 9.

•  Lock must be opened within 4 seconds once a valid combination has been entered. 
•  To open a container with a Swing Bolt Lock, turn the container handle to the open position and open the door. 
•  To open a container with a Dead or Spring Bolt Lock, turn the keypad or dial to retract the bolt and open the door. 
•  When closing a container, verify that it has been secured. 

With eKEY(Dual Token)
NOTE: 

Locks must be factory programmed with this feature enabled. The eKEY is a 48-bit encrypted unique serial number dual 

token device. 

• To open the Lock, enter combination, insert and quickly remove the eKEY. The Lock will open after the eKEY is removed.
• To access Lock commands, enter combination and insert the ekEY until Lock double signals and the LED stays on. 

LOCK RESPONSES 

Standard Operations

Entry Devices with LEDs (3125, 3190 and 3750-K) respond with both LED flashes and beeps. 
•  Single signal - one (1) LED flash and one (1) beep indicate the operation is complete. 
•  Double signal - two (2) LED flashes and two (2) beeps indicate entry is valid or accepted. 
•  Triple signal - three (3) LED flashes and three (3) beeps indicate invalid or not accepted. 

NOTE: 

The 8130 Entry Device (no LED) responds with beeps only. 

Additional Operations

•  Delay Period - The LED will flash once every second.  
•  Open Period - The LED will flash twice a second, and the Entry Device will beep every 10 seconds.  
•  Penalty Period - The LED will flash every ten (10) seconds.  
•  Low Battery Warning - During a Lock opening, the LED will flash and Entry Device will beep repeatedly.  

Summary of Contents for AuditGard

Page 1: ...minutes Open Period 1 19 minutes Note If the Time Delay On is not selected then this feature is inactive This feature may be enabled later Refer to Manager Instructions 759 128 COMBINATION LENGTH A c...

Page 2: ...ken Note Locks must be factory programmed with this feature enabled The eKEY is a 48 bit encrypted unique serial number dual token device To open the Lock enter combination insert and quickly remove t...

Page 3: ...re two types of programming cables used with the AuditGard P N 42145 or P N 43087 depending upon which Entry Device is used CONFIGURE LOCK SETTINGS Start the Setup Program Select the AG Setup icon fro...

Page 4: ...rts COM LPT The list of communication and printer ports currently identified in the PC system will be displayed e Plug the USB or Serial Interface Adapter into an available USB port on the PC If using...

Page 5: ...elect Mode s Select by placing a check mark in the desired operational Mode External Signals and Time Delay Multiple modes can be selected Silent Alarm If selected a LA GARD alarm box will be required...

Page 6: ...049 Rev A 06 10 copyright 2010 Kaba Mas LLC page 6 of 13 Time Delay Override If selected User 9 must be installed to use this option If selected the software will automatically install User 9 Figure 6...

Page 7: ...to the other option Figure 8 Select Time Delay The Delay and Open Periods may be set up in this window Enable feature by placing a check mark in the Time Delay On box Then enter the desired time perio...

Page 8: ...ock Reset and if selected Enable Disable Disable the Manager Figure 11 The Master CANNOT open the Lock Refer to Master Instructions 788 0310 Note If the default combination is change using the softwar...

Page 9: ...13 Figure 13 5 Click on the Transmit button in the software Figure 14 6 Press the 0 key on the keypad to begin transmitting the configurations to the lock Figures 15 16 17 If the COM port has been in...

Page 10: ...iguration Once the setup configuration has been completed you may name and save the setup file xml for future use 1 Click the Save button or on the Files tab at the top of the program and select Save...

Page 11: ...onfiguration file has been saved it may be used to program a Lock by using the Load function of the AuditGard Setup software 1 Click the Load button or select Load from the File menu on the Menu bar F...

Page 12: ...efault 1 2 3 4 5 6 2 Open the Lock within four 4 seconds To complete the activation and add User s combinations the Manager combination MUST be changed CHANGE MANAGER COMBINATION 1 Enter the Manager c...

Page 13: ...f the lock does not open disconnect the Reset Box and repeat steps 2 and 3 5 Disconnect Reset Box The Lock is now in Factory default and can be reprogrammed using AuditGard Setup Software SOFTWARE RES...

Reviews: