Select the COM Port

When the Setup program is started, it identifies the COM Ports that are currently available on your PC. You must select the COM Port 
to be used when communicating with the lock each time you start the program. 
1. Access the Device Manager to determine which COM Port to select for the Setup Software by completing the following steps: 
    a. Right click on 

My Computer

.

    b. Select 

Manage

.

      The Computer Management window is displayed.  
    c. Under System Tools, select the 

Device Manager

.

    d. From the Device Manager list, select 

Ports (COM & LPT)

.

      The list of communication and printer ports currently identified in the PC system will be displayed. 
    e. Plug the USB or Serial Interface Adapter into an available USB port on the PC.
     

If using a USB Adapter

, the list of ports will be updated to reflect the new device. The LA GARD USB Interface Adapter can 

      be identified in the list as 

USB Serial Adapter

. The virtual COM Port assigned to the USB port where the Adapter is currently 

      installed will follow the device description (Figure 3).

Figure 3.

     

If using a Serial Adapter

, identify the standard Serial COM Port to be used. Standard Serial COM Ports are identified in the 

      list with a description of 

Communications Port

.

2. From the Setup software, select the 

Configuration

 menu on the Menu bar. 

  The list of available COM Ports will be displayed. 

Summary of Contents for AuditGard

Page 1: ...minutes Open Period 1 19 minutes Note If the Time Delay On is not selected then this feature is inactive This feature may be enabled later Refer to Manager Instructions 759 128 COMBINATION LENGTH A c...

Page 2: ...ken Note Locks must be factory programmed with this feature enabled The eKEY is a 48 bit encrypted unique serial number dual token device To open the Lock enter combination insert and quickly remove t...

Page 3: ...re two types of programming cables used with the AuditGard P N 42145 or P N 43087 depending upon which Entry Device is used CONFIGURE LOCK SETTINGS Start the Setup Program Select the AG Setup icon fro...

Page 4: ...rts COM LPT The list of communication and printer ports currently identified in the PC system will be displayed e Plug the USB or Serial Interface Adapter into an available USB port on the PC If using...

Page 5: ...elect Mode s Select by placing a check mark in the desired operational Mode External Signals and Time Delay Multiple modes can be selected Silent Alarm If selected a LA GARD alarm box will be required...

Page 6: ...049 Rev A 06 10 copyright 2010 Kaba Mas LLC page 6 of 13 Time Delay Override If selected User 9 must be installed to use this option If selected the software will automatically install User 9 Figure 6...

Page 7: ...to the other option Figure 8 Select Time Delay The Delay and Open Periods may be set up in this window Enable feature by placing a check mark in the Time Delay On box Then enter the desired time perio...

Page 8: ...ock Reset and if selected Enable Disable Disable the Manager Figure 11 The Master CANNOT open the Lock Refer to Master Instructions 788 0310 Note If the default combination is change using the softwar...

Page 9: ...13 Figure 13 5 Click on the Transmit button in the software Figure 14 6 Press the 0 key on the keypad to begin transmitting the configurations to the lock Figures 15 16 17 If the COM port has been in...

Page 10: ...iguration Once the setup configuration has been completed you may name and save the setup file xml for future use 1 Click the Save button or on the Files tab at the top of the program and select Save...

Page 11: ...onfiguration file has been saved it may be used to program a Lock by using the Load function of the AuditGard Setup software 1 Click the Load button or select Load from the File menu on the Menu bar F...

Page 12: ...efault 1 2 3 4 5 6 2 Open the Lock within four 4 seconds To complete the activation and add User s combinations the Manager combination MUST be changed CHANGE MANAGER COMBINATION 1 Enter the Manager c...

Page 13: ...f the lock does not open disconnect the Reset Box and repeat steps 2 and 3 5 Disconnect Reset Box The Lock is now in Factory default and can be reprogrammed using AuditGard Setup Software SOFTWARE RES...

Reviews: