SPECIAL FEATURES

 

B) Time Delay:

If feature is active:

 

After entering a valid code (double signal) the delay period starts, the LED
flashes at one second.
At the end of the delay period the Open window starts, the LED flashes twice
per second and the lock beeps every 10 seconds.
To open the lock, a valid code has to be entered during the Open window.  If
the Open window expires without the lock being opened, it is automatically
locked again.

Delete current delay time: press random key.

Extend current delay time: enter valid code. The delay period will start again.

Time delay Override:

 

Second code can open immediately. (When programmed)

C) Dual combination operation:

If feature is active:

Two codes are required to open, both codes can be changed independently. 
Feature A (Manager Mode) is cancelled when programming the dual
combination operation.
If Time Delay is active, one valid code will start the delay period. To open the
lock, both codes have to be entered during the Open window. 

D) Hold-up alarm (silent alarm):

If feature is active AND optional alarm box or SP-box is connected. 

If the last digit is chosen one higher or lower (+/- 1) when entering the code, the
lock will open as usual (double signal), but at the same time the alarm box is
activated.
Example:

Combination 471147
Alarm  

471146 or 471148.

E) Remote control:

If feature is active AND optional alarm box or SP-box is connected.

If six beeps and blinks follow upon the entry of a valid code, the lock is blocked
by the alarm feature (remote control) and will not open. The alarm can be
signalled as usual.

Program alterations and/or connection to an alarm system can also be carried through
afterwards. Inquire with your dealer or visit us on Internet (http://www.lagard.en

).

USER INSTRUCTIONS

COMBOGARD 33E (3040)

3035

= Rubber key entry

3075

= Black foil entry 

3750

= Black foil entry with battery box

GENERAL

The lock operates with a 6-digit code or word of 6
characters. Ability to add a second User combination.
Each entry is confirmed by a beep-and-blink
signal.

A valid code is followed by a double signal, an
invalid code by a triple signal.
After an interval of more than 10 seconds, the
already entered part of the code is deleted and
the entire sequence has to be re-entered.

1. TO OPEN THE LOCK

The factory code is 1-2-3-4-5-6. 
Enter the code and (after double signal) turn the entry
clockwise within 3 seconds unto the hold.  
The lock is open and the entry is rotated. 
If the lock is not entered within 3 seconds, it is
automatically locked again.

2

. TO CLOSE THE LOCK

Turn the entry counter-clockwise unto the hold. 
The lock is closed and the entry stands straight.
 

3. WRONG TRY PENALTY

After four invalid codes, the entry is blocked for about 5 minutes. During this
period, the lock signals at 10 second intervals. After this time penalty, the entry of
every second invalid code initiates a new 5 minutes delay period.