SAVE SETUP CONFIGURATION 
Once the setup configuration has been completed, you may name and save the setup file (*.xml) for future use.
1. Click the 

Save button or on the Files tab at the top of the program and select Save (Figure 15).

2. Name the file and click the 

Save button (Figure 16).

Figure 15

Figure 16

ACTIVATE THE LOCK 
1. Press and hold the 

0 key until the lock signals twice.

2. Enter any valid combination within 40 seconds.
  The lock will signal twice then one long beep (approximately 2 seconds). The lock is now fully functional, but still in Setup. This 
  means the Manager still has the ability to change the lock configuration. To complete the activation and freeze the lock’s 
  configuration, the Manager combination MUST be changed. Prior to changing Manager Combination, SMR must be set up or it will 
  be lost. (Please refer to Page 2 of this document for SMR instructions.)

To change the Manager combination, follow the steps below:
CAUTION: 
Always perform this operation with the door open!

3. Enter the Manager combination and hold down the last digit until unit double signals twice release and the LED stays on.
4. 

PRESS 0.

5. Enter the NEW combination.
6. Re-enter the NEW combination to confirm. The lock is now active and the configuration is frozen. 
NOTE: To change the settings after the configuration has been frozen, the lock must first be reset. Refer to the Reset Lock section of 
this document.

Summary of Contents for ComboGard Pro 39E

Page 1: ...lable if enabled using Setup software and with Lock code level 39E v1 09 or higher TIME DELAY Delay Period 1 99 minutes Open Period 1 19 minutes NOTE If the Time Delay On is not selected then this feature is inactive This feature may be enabled later Refer to Manager Instructions 732 018 COMBINATION LENGTH A combination length from six 6 to nine 9 digits may be selected NOTE To maintain the VdS Cl...

Page 2: ... back to factory state but the SM code remains unchanged The default code of 5 5 5 5 5 5 5 5 must be changed before the Manager default code is changed or the Super Master Reset function will be permanently lost Process is as follows Action Press and hold 0 key for 3 seconds Result Lock beeps twice and the LED remains ON throughout the entire process Action Enter default code of 5 5 5 5 5 5 5 5 Pr...

Page 3: ...teps a Right click on My Computer b Select Manage The Computer Management window is displayed c Under System Tools select the Device Manager d From the Device Manager list select Ports COM LPT The list of communication and printer ports currently identified in the PC system will be displayed e Plug the USB or Serial Interface Adapter into an available USB port on the PC If using a USB Adapter the ...

Page 4: ...or a Serial Adapter select the standard Serial COM Port to be used Figure 3 Select Mode s Select by placing a check mark in the desired operational Mode Silent Alarm External Signals and Time Delay Multiple modes can be selected Silent Alarm If selected a LA GARD alarm box will be required to use this feature Dual Mode If selected two combinations are required to operate the lock At least one addi...

Page 5: ... Box required P N 2789NC By placing a check mark in the desired option select either Disable Opening Remote Time Delay Override or Remote Override Figure 7 Disable Opening Input signal to the Alarm Box will disable the opening of the lock by a valid combination Remote Time Delay Override Input signal to the Alarm Box will disable the time delay and allow the opening of the lock by any valid combin...

Page 6: ...n is not selected this feature is inactive This feature may be enabled later by the Manager Refer to ComboGard Pro Manager Instructions 732 018 Figure 6 Figure 7 Figure 8 Install Users The Manager cannot be disabled because the Manager must be installed with a combination in order to activate the lock To install a User place a check mark in the Installed box next to the User ID When a User is sele...

Page 7: ...4 Plug the programming cable into the audit programming port of the Entry Device Figure 10 5 Click on the Transmit button in the software Figure 11 6 Press the 0 key on the keypad to begin transmitting the configurations to the lock Figures 12 13 14 If the COM port has been incorrectly set return to the setup window Figure 2 and reset the COM port to the correct one If you do not know which COM po...

Page 8: ... P N 731 018 Rev H 12 14 copyright 2008 2014 Kaba Mas LLC page 8 of 11 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 ...

Page 9: ... the Manager still has the ability to change the lock configuration To complete the activation and freeze the lock s configuration the Manager combination MUST be changed Prior to changing Manager Combination SMR must be set up or it will be lost Please refer to Page 2 of this document for SMR instructions To change the Manager combination follow the steps below CAUTION Always perform this operati...

Page 10: ...nter combination length a second time and press 0 to confirm Example setting a combination length to seven digits Enter 5 5 5 5 5 5 hold down the last number 8 7 0 7 0 6 To test enter default Manager combination 5 5 5 5 5 5 5 all fives to length of combination Lock will signal twice and lock will open NOTE If combination length is changed after Users are enrolled all Users will be deleted and must...

Page 11: ... LOCK To complete the activation of the lock and freeze the configuration the Manager combination MUST be changed Please note SMR must be changed first or it will be lost To change the Manager combination follow the steps below CAUTION Always perform this operation with the door open 1 Enter the default Manager combination and hold down the last digit until unit double signals twice and the LED st...

Reviews: