VIEWABLE AUDIT CODES

When viewing the Audit on the LCD, the following is a list of code descriptions.

U:

  User number, where 0 is the Master 0 and 1 is the Master 1. All other numbers correspond to the appropriate user 02 through 99.

L:

  Lock number where 0 is the Logic Module. All other numbers correspond to the locks enrolled in the system.

C:

  The code number for the event. See list below for a reference.

U 255 REFERS TO ANY OPERATION PERFORMED BY THE LOGIC MODULE, I.E. TIME DELAY SUSPEND, POWER UP AND BATTERY LOW.

03 

COMBO CHANGE

05 

DOOR OPEN

06 

BOLT SWITCH OPEN

08 

TIME DELAY START

0B 

1ST DUAL USER

0E 

BATTERY LOW

10 

USER ENABLED

11 

USER ENROLLED

12 

USER DISABLED

13 

USER DELETED

27 

AUDIT FILE REQUEST

29 

TIME DELAY CHANGE

30 

ENTER MASTER MENU

31 

ENTER MANAGER MENU

32 

ENTER TIME MENU

33 

ENTER PC LINK

34 

LEAVE PC LINK

40 

SET TIME DATE

41 

SET TIME LOCK

42 

SET SPECIAL EVENT

43 

LOCK INSTALL

44 

LOCK REMOVE

45 

MANAGER INSTALL

46 

MANAGER DELETE

47 

ASSIGN LOCK

48 

VIEW AUDIT

4A 

MANAGER FINGERPRINT ENROLL

4B 

SET SYSTEM OPERATION MODE

4C 

SET IMMEDIATE TIME LOCK

4D 

SET OPEN OFFSET

4E 

SET EXTENSION TIME

4F 

SET ACCESS LIMIT

50 

RTC FAIL

51 

FINGER MODULE FAIL

52 

OPEN CANCEL

54 

DURESS ACCESS

55 

MANAGER DISABLED

56 

MANAGER ENABLED

57 

MANAGER RIGHTS ASSIGNED

58 

MANAGER RIGHTS REMOVED

62 

IDENTIFICATION FINGERPRINT FAIL

63 

CODE TO FINGERPRINT NOT MATCH

F0 

POWER UP

F3 

POWER OFF

F5 

WRONG TRY

F6 

TIME PENALTY START

FA 

FACTORY RESET

FF 

EEPROM MEMORY INIT

LA GARD’s customer service department can be reached 24 hours a day, seven days a week. They are ready to assist with any 

questions regarding the SMARTPOInT or any LA GARD product. Please contact them, toll-free at (877-522-2627).  

Visit us on the web at www.kaba-mas.com.

Summary of Contents for SmartPoint

Page 1: ...ds page 3 2 3 Time Lock Special Events Verify page 3 2 3 1 Add Remove Special Events page 3 2 4 View Audit page 4 2 5 PC Link page 4 2 6 System Set up page 4 2 6 1 Install Locks to Logic Module page 4 2 6 2 Remove Locks from Logic Module page 5 2 6 3 Assign Lock page 5 2 6 4 System Operation Mode page 5 2 6 5 Access Limit page 5 2 6 6 System Information page 5 2 7 Audit Functions page 6 2 7 1 Audi...

Page 2: ...menu you can verify all stored opening periods 1 Press any key to power up SMARTPOINT Display will show either ENTER CODE or SELECT LOCK when two or more locks are installed 2 Hold down zero until the display shows MASTER CODE X X X X X X X X 3 Enter master code If a valid code is entered the display will show TIME DATE 4 Press P to select the next function the display will show TIME LOCK STAND WE...

Page 3: ...ER CODE X X X X X X X X 3 Enter master code If a valid code is entered the display will show TIME DATE 4 Press P two 2 times to select the next function the display will show TIME LOCK SPECIAL EVNT 5 Press OK to select Special Events Menus the display will show the first closing period stored 6 Press OK to scroll through all stored closing periods To delete an opening period first install a new op...

Page 4: ...tically based on number of days assigned System Information Shows firmware version set in Logic Module NOTE IF THERE IS A LOCK SET TO AUTO OPEN In a multiple lock system you can set an outer door lock to AUTO OPEN This will allow the user if authorized to open the inner compartment lock and have the outer door lock automatically open The AUTO OPEN lock always opens first SYSTEM SET UP 1 Press any ...

Page 5: ...tion options Options include USER CODE default 2 USER CODE FINGER ONLY FINGER CODE 2FINGERS 2FINGR 2CODE 5 After scrolling to appropriate operation press OK to select display will show SYSTEM OPER MODE 6 Press P to esc from menu 2 6 5 SYSTEM SET UP Access Limit Ability to disable users automatically based on number of days assigned if the Users code is not entered within the time frame assigned Fo...

Page 6: ... Logic Module 4 Select a date range or leave circle for all events checked 5 Connect cable to port on Logic Module 6 Press any key to power up SMARTPOINT Display will show either ENTER CODE or SELECT LOCK when two or more locks are installed 7 Hold down zero until the display shows MASTER CODE X X X X X X X X Enter the Master code 8 Press the P button four 4 times to select PC Link the display wil...

Page 7: ...n Unit will beep again and the display will show 2nd SCANNING then 3rd SCANNING Once scanning is completed the display will show ANOTHER FINGER The system offers the option of scanning up to three 3 fingers for each User or the Manager For optimal results finger should be lifted after each scan and then quickly replaced so that three separate captures are made Repeat this procedure for each finger...

Page 8: ...isplay will show TIME DATE 4 Press P six 6 times to select the User Menu the display will show USERS ON OFF 5 Press OK to view the User status the display will show USERS ON OFF XX XX 6 Press User ID XX to select a user display will show USER ID X DISABLE 7 Press OK display will show USERS ON OFF XX XX 2 8 4 MASTER MENU Users Enable A User 1 Press any key to power up SMARTPOINT Display will show e...

Page 9: ...P three 3 times display will show USER ID X ADD DEL MGR 8 Press OK display will show REMOVE MANAGER or MAKE MANAGER if the user was originally added without the manager feature added 9 Press OK display will show MANAGER REMOVED or MANAGER ADDED 10 Press OK display will show USERS ON OFF XX XX 2 8 7 MASTER MENU Users Add Remove Time Delay Override 1 Press any key to power up SMARTPOINT Display will...

Page 10: ...r up SMARTPOINT Display will show either ENTER CODE or SELECT LOCK when two or more locks are installed 2 Hold down zero until the display shows MASTER CODE X X X X X X X X 3 Enter master code If a valid code is entered the display will show TIME DATE 4 Press P seven 7 times to select the TIme Delay Menu the display will show TIME DELAY 5 Press OK to enter the Time Menu the display will show TIME ...

Page 11: ... ENTER MASTER MENU 31 ENTER MANAGER MENU 32 ENTER TIME MENU 33 ENTER PC LINK 34 LEAVE PC LINK 40 SET TIME DATE 41 SET TIME LOCK 42 SET SPECIAL EVENT 43 LOCK INSTALL 44 LOCK REMOVE 45 MANAGER INSTALL 46 MANAGER DELETE 47 ASSIGN LOCK 48 VIEW AUDIT 4A MANAGER FINGERPRINT ENROLL 4B SET SYSTEM OPERATION MODE 4C SET IMMEDIATE TIME LOCK 4D SET OPEN OFFSET 4E SET EXTENSION TIME 4F SET ACCESS LIMIT 50 RTC ...

Reviews: