2
Care and safe use guidelines
carry out the service and checks periodica
ATTENTION: This appliance is fitted with flexible gas rubber pipe and clamps that must be used; never use a
different type. These components should be periodically checked for deterioration, this is very important; if
holes occur in the components, this could cause a gas explosion. Always get a certified gas engineer to
lly.
The LPG cylinder is not included and must be purchased (Recommended 5kg)
WARNING:
•
Do not modify the appliance.
•
Do not move the appliance during use.
•
Turn off the gas supply at the LPG cylinder after use.
•
Accessible parts may be very hot. Keep young children away.
•
The appliance should not be used indoors.
•
The appliance must only be used for space heating.
•
THIS APPLIANCE HAS A NAKED FLAME; A SUITABLE GUARD SHOULD BE USED FOR
THE PROTECTION OF YOUNG CHILDREN, THE ELDERLY AND THE INFIRM.
•
CARBON MONOXIDE HAZARD
DO NOT use this appliance in confined spaces or indoors as it can kill you.
SPECIFICATION
Product Name
Leopold
Model
58287 (HF35401AA)
Gas Type
LPG gas mixture
Butane at
(28~30)mbar/
Propane at
37mbar
LPG gas
mixture
LPG gas
mixture
Gas Category
I
3+
I
3B/P(30)
I
3B/P(37)
I
3B/P(50)
Heat input (Hs)
13 kW(946g/h)
13 kW(946g/h) 13 kW(946g/h) 13 kW(946g/h)
Gas pressure
G30 at 28-30mbar
G31 at 37mbar
G30/G31
at 30mbar
G30/G31
at 37mbar
G30/G31
at 50mbar
Injector diameter (Ø) and No. 1.84 mm
1.84 mm
1.74 mm
1.59mm
Destination countries
BE,CH,CY,CZ,ES,
FR,GB,GR,IE,IT,LT
,LU,LV,PT,SK,SI
BE,
CY,DK,EE,FI,F
R,HU,IT,LT,NL,
NO,SE,SI,SK,
RO,HR,TR,BG
,IS,LU,MT
PL
DE, AT, CH,
SK
Gas regulator
Certified regulator according to EN 12864 (flow rate: max. 1.5kg/h)
Gas hose
Certified gas hose according to applicable EN-standard (max1.5m)
Gas cylinder
Standard gas cylinder (recommend to use 4.5kg ~ 15kg)
Primary air regulation
Fix - not adjustable
Appliance mass:
50 kg