Summary of Contents for EC

Page 1: ...FOR MODEL EC Page 1 of 11 EC Engine Start Battery Charger INSTRUCTION MANUAL ECN DATE CPN106604 18985 4 11 16816 11 05 106 BRADROCK DRIVE DES PLAINES IL 60018 847 299 1188 FAX 847 299 3061 ISSUE DATE...

Page 2: ...the eye with running cold water for at least ten 10 minutes and get medical attention immediately 5 Never smoke or allow a spark or flame in vicinity of a battery 6 Be extra cautious DO NOT drop meta...

Page 3: ...Mfg may void warranty service for any physical damages reported for repair HANDLING WARNING Equipment can be very heavy and top heavy Use adequate manpower or equipment for handling Until the equipmen...

Page 4: ...r cell equalize nickel cadmium cell The charger is factory tested and preset so that no field adjustments are necessary In normal operation the EC Charger maintains a constant battery voltage If the b...

Page 5: ...rating 2 Check unit specifications with customer order 3 Check input connections input voltage and line breaker size 4 Check for shipping damage loose connections broken wires etc 5 Certain failures c...

Page 6: ...operates but will not charge battery 1 Defective capacitor 2 Open cell in battery To check capacitor measure resistance with one capacitor lead disconnected it should read high resistance Check batter...

Page 7: ...MENT REQUIREMENT GROUNDING FUSE CUSTOMER CONDUCTOR SIZE CONNECTION MINIMUM 1 14 14 3 14 14 4 14 14 5 14 14 6 14 14 10 14 14 15 12 12 20 12 12 25 10 12 30 10 10 35 8 10 40 8 10 45 8 10 50 8 10 60 6 10...

Page 8: ...2000 2000000 Denotes all sizes larger than 0000 are expressed in MCM TABLE OF CONVENTIONS CMA Cross section of wire in circular MIL area A Ultimate drain in amperes LF Conductor loop feet MAX AMP Maxi...

Page 9: ...4 Check front panel meters and alarms for accuracy 4th Year REPEAT ABOVE WITH THE ADDITION OF 1 Check relay contacts for pitting or corrosion 2 Check capacitors for leakage 7th Year REPEAT ALL WITH T...

Page 10: ...by purchaser 2 If the purchaser elects not to return the equipment to the factory and wishes a factory service representative to make adjustments and or repairs at the equipment location La Marche s...

Page 11: ...sting performed by factory personnel Should it be necessary to return a piece of equipment or parts to the factory the customer or sales representative must obtain authorization from the factory If up...