English
Firenze - Italia
Description
Display
Operating Procedure
10
La Marzocco, S.r.l. Firenze, Italia
Version 1.3
Proportional, Integral, Derivitive (PID) Settings
Factory Level Parameters
kP kI kD
3.8 0.04 10.0
•
This parameter is preset at the factory based upon
theoretical calculations and physical experiments.
•
It is not recommended that these numbers are
changed.
•
Changes to these parameters can cause unexpected
results.
•
Qualified technicians may wish to experiment with
different values.
•
It is important to write down the values before making
changes to be sure you can return to the factory
programming if unexpected results occur.
Press and hold the
button on the group 1 keypad until the following is displayed
(approximately 10 seconds):
Enter the 5 digit factory password using buttons 1-5 on the group 1 keypad. Once accepted the
following appears:
1
2
Password
?????
LaMarzocco 09:30
Press the
button on the group 1 keypad until the following appears (three times):
3
Groups Number
3
Press the
or the
button to change the value of the flashing parameter. When the desired
value is displayed press to
confirm and advance to the next value.
4
MODE
kP kI kD
3.8 0.04 10.0
+
ENTER
When finished, continue to the next parameter or press
to exit programming mode.
5
ON
OFF
Software Programming Manual - ENG - V 1.3.pmd
30/10/2006, 14.39
10