Setting up the Swift
Grinder S/D
Regulation of single and
double doses: to establish
the doses on this specific
grinder it is necessary to read
through the procedures for
the standard Swift under
the section
“Regulation of
quantity for dosing”
as well
as follow these procedures.
BOtH MOtORS AND
HOPPERS CAN DELiVER
SiNGLE AND
DOUBLE DOSES
It is mandatory to proceed as
follows:
Double dose:
1) Turn off the machine and
remove the front tower
cover to access to the
screws that fix the shaft of
the impeller.
2) Set the quantity of the
coffe in the filter as on the
standard Swift model.
(see image A)
3) Adjust the grind (double):
adjust the grind to extract
60ml in 25 seconds.
4) Set the height of the
cylindrical
ring:
the
cylindrical ring next to the
impeller should be at a
height that allows to obtain
a coffee puck surface that
is completely even.
NOtE:
The regulation of the
height of the cylindrical ring
(moveable part or tamper)
is carried out by rotating
the part clockwise to lift the
ring and rotating it counter
clockwise to lower.
The cylindrical ring is held
in place by two brass screws
(see image b) so that the
vibrations caused by the
rotation of the impellers do
not alter its position.
Remove the two screws and
manually rotate the part,
grasping it from the bottom.
the distance between the
impeller and the cylindrical
ring can vary from a minimum
of 4 mm to 6 mm, a length
that permits to obtain a
perfectly even coffee puck
(see picture below).