INSERTO Crystal
50 – 50v – 50v p30 – 70 – 80 – 100
6096801 – EN
23
8. EXTERNAL AIR INTAKE
For a good operation of the appliance, it is essential that a sufficient quantity of air for the combustion and the re-
oxygenation of the room is introduced the installation room itself. This means that, through proper openings
communicating with outside, the air for combustion must circulate also with closed doors and windows.
•
The air intake must be positioned so that it cannot be obstructed.
•
Be communicating with the installation room of the appliance and be protected by grating.
•
Minimum surface must not be lower than 113 cm
2
.
•
Should the inflow of air be obtained by openings communicating with outside of nearby rooms, it is
necessary to avoid air intakes in connection with garages, kitchens, bathrooms, thermal units (see
Picture 17
).
•
If in the local of installation there are inspiration hoods, these cannot work at the same time, as the
contemporary use of them could cause the smoke exit in the room, even if the door is closed.
OPTIONAL
For a better comfort and corresponding oxygenation of environment, the stove / insert combustion air can be directly
withdrawn at the outside. (Picture 18).
Picture 17
Picture 18
(2) Seal
(3) Insulating coating with external
aluminum sheet
(4) Door for cleaning
(5) External air intake
(1) Insulating material
(6) Heat drain grating
(7) Fire-retardant counter-hood
(9) Shield wooden parts with
insulating material
(10) Min. distance between Coating
and insert
see MARKING INFORMATION
(8) Maximum inclination 45°
6016040 - kit
OPTIONAL
- INSERTO Crystal 50 - 50v - 50v:p30
6016041 - kit
OPTIONAL
- INSERTO Crystal 70 - 80 - 100
50v p30
Ø 120
160 mm INSERTO 50v p30
200 mm INSERTO 50-50v-70-80-100