4.1. FIRST-AID MEASURES 

Should any fire arise in the stack or in the flue: 

a)  Close the feeding door and the ash drawer door
b)  Close the registers of combustion air 
c)  Extinguish the fire using carbon dioxide fire-fighting means (CO

dust). 

d) 

Seek immediate intervention of FIRE BRIGADE.

 

 
DO NOT EXTINGUISH FIRE USING WATER JETS

 

When the fire has been extinguished, let the flue check by an expert  to find possible cracks and permeable 
points. 

5.  FLUE 

Essential requirements for a correct operation of the device: 

• 

the internal section must be preferably circular; 

• 

be thermally insulated and water-proof and produced 

with  materials  suitable  to  resist  to  heat,  combustion 
products and possible condensates; 

• 

not  be  throttled  and  show  a  vertical  arrangement  with 

deviations not greater than 45°; 

• 

if already used, it must be clean; 

• 

observe the technical data of the instructions manual;

 

Should  the  flues  have  a  square  or  rectangular  section, 
internal  edges  must  be  rounded  with  a  radius  not  lower 
than  20  mm.  For  the  rectangular  section,  the  maximum 
ratio between the sides must be 

  1.5. 

A too small section causes a decrease of the draught. 
It is suggested a minimum height of 4 m. 
The  following  features  are  forbidden  and  therefore  they 
endanger the good operation of the device: 
asbestos  cement,  galvanized  steel,  rough  and  porous 
internal  surfaces.  Picture  3  gives  some  examples  of 
execution.

 

 
The minimum section must be 4 dm

(for example 20 x 

20 cm) for devices whose duct diameter is 
lower than 200 mm or 6.25 dm

(for example 25 x 25 cm) 

for devices with diameter greater than 200 
mm. 
The draught created by the flue must be sufficient, but not 
excessive. 
A too big flue section can feature a too big volume to be heated and consequently cause difficulties in the 
operation  of the  device; to avoid this,  tube  the flue  along  its  whole  height. A  too  small  section  causes  a 
decrease of the draught. 
The  flue  must  be  properly  spaced  from  any  flammable  materials  or  fuels  through  a  proper 
insulation or an air cavity. 
It is forbidden to let plant piping or air feeding channels pass in the same flue. Moreover, it is forbidden to 
create movable or fixed openings on the same for the connection of further other devices. 

5.1. CHIMNEY CAP POSITION 

The draught of the flue depends also on the suitability of the chimney cap. 
Therefore, if it is handicraft constructed, the output section must be more than twice as big as the internal 
section of the flue. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Picture 3 

(1)    AISI  316  steel  flue  with  double  chamber 
insulated  with  material  resistant  to  400°C. 
Efficiency 100% excellent.

 

 
(2) Refractory flue with double insulated chamber 
and  external  coating  in  lightweight  concrete. 
Efficiency 100% excellent.

 

  
(3) Traditional clay flue square section with 
cavities. Efficiency 80% excellent.

 

 
(4)  Avoid  flues  with  rectangular  internal  section 
whose  ratio  differs  from  the  drawing.  Efficiency 
40% poor.

 

A+1/2A 

 

A

 

 

 

Max. 
A+1/2A

 

 

 

(3) 

 

 

 

(1) 

 

 

 

(2) 

 

 

 

(4) 

 

 

 

Summary of Contents for ROSSELLA PLUS

Page 1: ...ft nach EN 13240 ISTRUZIONI PER L INSTALLAZIONE L USO E LA MANUTENZIONE IT INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE EN ANWEISUNGEN F R DIE AUFSTELLUNG DEN GEBRAUCH UND DIE WARTUNG DE NORME D...

Page 2: ...Rossella Plus Rossella Plus forno Nicoletta Nicoletta forno 2 Istruzioni Instructions Anweisungen IT EN DE Rev 02...

Page 3: ...ence of asbestos and cadmium We declare that the materials used for the assembly of all our appliances are without asbestos parts or asbestos derivates and that in the material used for welding cadmiu...

Page 4: ...PLATTE 43 17 MONTAGGIO DELLE MAIOLICHE ASSEMBLY OF THE MAJOLICS KACHELN AUFSTELLUNG NICOLETTA NICOLETTA FORNO 44 18 SCHEDE TECNICHE TECHNICAL DATA SHEETS TECHNISCHE PROTOKOLLE 45 INDEX EN 1 TECHNICAL...

Page 5: ...DER VERBRENNUNG 36 8 ZUL SSIGE UNZUL SSIGE BRENNSTOFFE 37 9 ANZ NDEN 38 10 NORMALBETRIEB 39 11 BETRIEB IN DER BERGANGSZEIT 39 12 BACKEN wenn anwesend 39 13 WARTUNG UND PFLEGE 40 13 1 REINIGUNG DES SC...

Page 6: ...lare testata focolare in mm LxHxP 374x325x350 374x325x350 374x325x350 374x325x350 Dimensioni forno in mm LxHxP 330x300x370 330x300x370 Tipo di griglia Griglia piana girevole dall esterno Altezza stufa...

Page 7: ...one Registro ARIA PRIMARIA Figura 1 A Con il registro posto in basso a SX della porta del focolare viene regolato il passaggio dell aria attraverso il cassetto cenere e la griglia in direzione del com...

Page 8: ...orta del focolare nell area di radiazione della stessa non deve esserci alcun oggetto o materiale di costruzione infiammabile e sensibile al calore a meno di 100cm di distanza Tale distanza pu essere...

Page 9: ...a resistere al calore ai prodotti della combustione ed alle eventuali condense essere priva di strozzature ed avere andamento verticale con deviazioni non superiori a 45 se gi usata deve essere pulita...

Page 10: ...ella canna fumaria Dovendo sempre superare il colmo del tetto il comignolo dovr assicurare lo scarico anche in presenza di vento Figura 4 Il comignolo deve rispondere ai seguenti requisiti avere sezio...

Page 11: ...collegamento alla canna fumaria deve essere pi corto possibile rettilineo a tenuta stagna e conforme alle normative vigenti Il collegamento deve essere eseguito con tubi stabili e robusti Vi consiglia...

Page 12: ...d aria esterna posta nelle vicinanze dell apparecchio oppure tramite la posa di una conduttura per l aria di combustione che porti verso l esterno od in un vicino locale areato ad eccezione del local...

Page 13: ...no essere utilizzati solo per l accensione La combustione di rifiuti vietata e danneggerebbe inoltre la stufa e la canna fumaria provocando inoltre danni alla salute ed in virt del disturbo olfattivo...

Page 14: ...altri mezzi di accensione in commercio escluse tutte le sostanze liquide come per es alcool benzina petrolio e simili Le aperture per l aria primaria e secondaria devono essere aperte contemporaneamen...

Page 15: ...ria per la combustione Caricate in seguito una quantit ridotta di combustibile facendo s che questo bruci pi rapidamente con sviluppo di fiamme e si stabilizzi cos il tiraggio della canna fumaria Cont...

Page 16: ...di lasciare sempre 3 4 cm di cenere nel focolare ATTENZIONE le ceneri tolte dal focolare vanno riposte in un recipiente di materiale ignifugo dotato di un coperchio stagno Il recipiente va posto su d...

Page 17: ...05 ogni curva del canale fumi riduce sensibilmente il tiraggio della canna fumaria che dovr essere eventualmente compensata innalzandola adeguatamente la Normativa UNI 10683 2005 ITALIA prevede che le...

Page 18: ...earth body size hearth head in mm LxHxP 374x325x350 374x325x350 374x325x350 374x325x350 Oven size in mm L x H x P 330x300x370 330x300x370 Grate type mobile flat Stove height in mm 915 1359 974 1423 St...

Page 19: ...age of air through the drawer of ash and the grate in the fuel direction The primary air is necessary for the combustion process The ash drawer must be regularly emptied so that the ash does not obstr...

Page 20: ...ilated and heat resistant protection All minimum safety measures are indicated in the plate of the products and they must be absolutely respected c if the chimney stove is installed on a floor not com...

Page 21: ...nt galvanized steel rough and porous internal surfaces Picture 3 gives some examples of execution The minimum section must be 4 dm2 for example 20 x 20 cm for devices whose duct diameter is lower than...

Page 22: ...ny possible maintenance and cleaning operation Picture 4 Picture 5 Picture 6 50 cm 1 In case of flues side by side a chimney cap must be higher than the other one of at least 50 cm in order to avoid p...

Page 23: ...ng to the current regulations The connection to the chimney must be performed with stable and strong pipes we recommend a thickness of 2 mm The pipe for smokes exhaust must be fixed hermetically to th...

Page 24: ...rnal air intake to be positioned in the nearby of the appliance or through air connection towards outside or a near ventilated room with the exception of thermal units place or garages forbidden The c...

Page 25: ...nt expires Paper and carton must be used only for ignition The combustion of wastes is forbidden and may damage the stove and the chimney causing health damages and claims by the neighbourhood owing t...

Page 26: ...th newspaper paper or other ignition media normally sold excluding all liquid substances as for ex alcohol gasoline petroleum or similar The openings for air primary and secondary must be opened toget...

Page 27: ...der to permit a rapid burning growing up of the flames and the stabilization of the draught Then check that all openings for the cleaning and the connections to the stack are air tigh 12 USE OF THE OV...

Page 28: ...fire resistant floor far from flammable materials up to the switching off and complete cooling The chimney of the stove must be regularly cleaned by the chimney sweeper Ask your chimney sweeper to ch...

Page 29: ...higher than 2 m UNI 10683 2005 each bend of the smoke channel considerably reduces the draught of the flue which must be compensated for by raising it suitably the UNI 10683 2005 Regulation Italy requ...

Page 30: ...x245 355x245 355x245 355x245 Gr e des Feuerraumsbodens des Feuertopfes in mm LxHxP 374x325x350 374x325x350 374x325x350 374x325x350 Gr e Backfachraum in mm LxHxP 330x300x370 330x300x370 Rosttyp Planros...

Page 31: ...unteren Ofenteil durch den Aschenkasten und den Rost in Richtung Brennstoff eingestellt Die Prim rluft ist f r den Verbrennungsproze notwendig Der Aschenkasten mu regelm ig entleert werden da die Asc...

Page 32: ...hbereich 45 d rfen sich in einer Entfernung von mindestens 100 cm kein entflammbarer oder hitzeempfindlicher Gegenstand oder Baumaterial befinden Diese Entfernung kann auf 40 cm verringert werden wenn...

Page 33: ...Querschnittreduzierung aufweisen und muss einen senkrechten Lauf mit Biegungen nicht hoher al 45 haben Wenn es schon angewandt worden ist muss es sauber sein Die technischen Angaben des Gebrauchshandb...

Page 34: ...t muss der Ausgangsquerschnitt zwangsm ig zwei Male gr er als der Innenquerschnitt des Schornsteinrohrs sein Da er den Firsttr ger immer berschreiten muss muss der Schornstein das Abblasen auch dann s...

Page 35: ...m H m 1 85 m 0 50 m vom First 15 1 85 m 1 00 m vom Dach 1 50 m 0 50 m vom First 30 1 50 m 1 30 m vom Dach 1 30 m 0 50 m vom First 45 1 30 m 2 00 m vom Dach 1 20 m 0 50 m vom First 60 1 20 m 2 60 m vo...

Page 36: ...Abzugsrohr oder im Schornstein verringert werden Aus Sicherheitsgr nden m ssen die fen au er beim Nachf llen von Brennstoff und der eventuellen Entfernung der Asche unbedingt mit geschlossenem Feuerr...

Page 37: ...ge Holz nicht geeignet f r einen Ofen Luftgetrocknetes Brennholz mit maximal 20 Wassergehalt erh lt man durch eine mindestens einj hrige Weichholz oder zweij hrige Hartholz Lagerung an einem trockenen...

Page 38: ...chen verbindet Daher ist es sehr wichtig dass Sie folgende Hinweise beim Anz nden befolgen 1 Sorgen Sie f r verst rkte Frischluftzufuhr zu dem Aufstellraum des Ofens 2 Bei den ersten Anz ndvorg ngen...

Page 39: ...der Verbrennungsluftschieber beeinflu t der Schornstein die Intensit t der Verbrennung und damit die Heizleistung Ihres Kaminofens Erh hter Schornsteinzug erfordert kleinere Verbrennungslufteinstellu...

Page 40: ...inen spezifischen Sekund rlufteingang wird der Verschmutzen der Scheibe sehr verz gert kann aber bei Festbrennstoffen berhaupt mit feuchtem Holz nie ausgeschlossen werden und stellt keinen Mangel dar...

Page 41: ...esch tzt werden wenn deren Aussehen ber lange Zeit in unver nderter Sch nheit erhalten bleiben soll 15 ANSCHLUSS AN DEN RAUCHABZUG EINES OFFENEN KAMINS Der Rauchkanal ist der Rohrabschnitt der das Pro...

Page 42: ...oletta Nicoletta forno 42 ANWEISUNGEN F R DIE AUFSTELLUNG DEN GEBRAUCH UND DIE WARTUNG DE Rev 02 F r jede weitere Erkl rung wenden Sie sich bitte an Ihren Vertrauensh ndler ABB 9 C Abdichtung A Hermet...

Page 43: ...sella Plus Rossella Plus forno Nicoletta Nicoletta forno Istruzioni Instructions Anweisungen IT EN DE Rev 02 43 16 POSIZIONE DEFLETTORE FUMI POSITION OF THE SMOKE DEFLECTOR STELLUNG DER RAUCHUMLENKPLA...

Page 44: ...nto causa la fragilit si possono danneggiare EN Place the lateral tiles A in one side starting from the bottom by hooking the holders B where the side supports C are Go on with the other side of the s...

Page 45: ...oletta forno Istruzioni Instructions Anweisungen IT EN DE Rev 02 45 18 SCHEDE TECNICHE TECHNICAL DATA SHEETS TECHNISCHE PROTOKOLLE ROSSELLA PLUS 156 kg 170 kg petra soapstone Speckstein ROSSELLA PLUS...

Page 46: ...Rossella Plus Rossella Plus forno Nicoletta Nicoletta forno 46 Istruzioni Instructions Anweisungen IT EN DE Rev 02 NICOLETTA NICOLETTA Forno...

Page 47: ...e tecniche designazioni che sono state applicate in accordo con le regole della buona arte in materia di sicurezza in vigore nella CEE sono The following harmonised standards or technical specificatio...

Page 48: ...n 20 cm Posteriore rear hinten 20 cm Emissione di CO 13 O2 Emission of CO 13 O2 CO Ausstoss bez auf 13 O2 0 05 1500 mg m3 Emissioni polveri 13 O2 Dust emissions 13 O2 Staubemissionen 13 O2 25 mg m3 Ma...

Page 49: ...ecifiche tecniche designazioni che sono state applicate in accordo con le regole della buona arte in materia di sicurezza in vigore nella CEE sono The following harmonised standards or technical speci...

Page 50: ...seiten 20 cm Posteriore rear hinten 20 cm Emissione di CO 13 O2 Emission of CO 13 O2 CO Ausstoss bez auf 13 O2 0 05 1500 mg m3 Emissioni polveri 13 O2 Dust emissions 13 O2 Staubemissionen 13 O2 25 mg...

Page 51: ...Rossella Plus Rossella Plus forno Nicoletta Nicoletta forno Istruzioni Instructions Anweisungen IT EN DE Rev 02 51...

Page 52: ...Data and models are not binding the company reserves the right to carry out modifications and improvements without notice Daten und Modelle sind unverbindlich die Firma beh lt sich das Recht f r nderu...

Reviews: