ENGLISH
FIRE SAFETY
When installing the product, the folloWing safety measures must be observed:
a) in order to ensure sufficient thermal insulation, respect the minimum safety distance from objects or furnishing components flammable
and sensitive to heat (furniture, wood sheathings, fabrics. etc.) and from materials with flammable structure (see
Picture 4
-
A
).
All
ThE mInImum SAFETY dISTAncES ARE Shown on ThE PRoducT dATA PlATE And lowER vAluES muST noT bE uSEd
(see
declaration of performance ).
b) in front of the furnace door, in the radiation area there must be no flammable or heat-sensitive objects or material at a distance of less than
Picture 4
-
A
. this distance can be reduced to 40 cm where a rear-ventilated, heat-resistant protection device is installed in front of the
whole component to protect.
c) if the product is installed on a non totally refractory floor, one must foresee a fireproof background.
ThE FlooRS
mAdE oF InFlAmmAblE mATERIAl
, such as moquette, parquet or cork etc.,
muST bE covEREd
by a layer of no-inflammable
material, for instance ceramic, stone, glass or steel etc. (size according to regional law). the base must extend at least
50 cm
at the front
and at least
30 cm
at the sides, in addition to the opening of the loading door (see
Picture 4
-
b
).
d) no flammable components (e.g. wall units) must be present above the product.
the product must alWays operate eXclusively With the ash draWer inserted. the solid combustion residues (ash) must
be collected in a sealed, fire resistant container. the product must never be on in the presence of gaseous emissions or
vapours (for eXample glue for linoleum, petrol etc.). never deposit flammable materials near the product.
during combustion, thermal energy is released Which leads to considerable heating of the surfaces, doors,
handles, controls, glass parts, the flue gas pipe and possibly the front part of the appliance.
AvoId conTAcT
wITh ThESE ElEmEnTS unlESS uSInG SuITAblE PRoTEcTIvE cloThInG oR AccESSoRIES
(heat resistant gloves,
control devices).
EnSuRE chIldREn ARE AwARE oF ThESE dAnGERS And KEEP ThEm AwAY FRom ThE FuRnAcE whEn IT IS on.
When using the Wrong fuel or one Which is too damp, due to deposits present in the flue, a flue fire is possible.
In A EmERGEncY
if there is a fire in the flue connection :
a) close the loading door and the ash drawer door
b) close the comburent air registers
c) use carbon dioxide ( co2 powder ) extinguishers to put out the fire
d) request the immediate intervention of the fire brigade
do noT PuT ouT ThE FIRE wITh wATER.
When the flue stops burning, have it checked by a specialist to identify any cracks or permeable points.