General Information on the logic board
Connection of the payment systems
A parallel coin mechanism can be connected to the 10 pin connector CN6 or to the 16 pin connector
CN5. These connectors supply, respectively, a power supply of 12V and 24V to the coin mechanism.
A serial coin mechanism with Executive protocol can be connected to connector CN8.
The parallel coin mechanism can be used contemporaneously with the serial coin mechanism.
Verifying and modifying of the working parameters
To enter the service menu press the “service key” indicated in the diagram for circa 1”.
To return to the normal state of vending of the machine press again this key or digit on the keypad
“Esc” (9) and confirm the selection with the “OK” (8) key.
Set up of default parameters
The board, for its functioning, avails of circa 800 different working parameters. Normally it is
necessary to modify only a few depending on specific needs. However, it is possible to automatically
re-install these parameters with the values contained in 3 distinct default tables.
To set-up one of the default tables you must turn the machine on whilst pushing down the “service
key” and the key “1” or “2” or “3” depending on the table.