background image

Service menu 

Use of the keypad 

All of the service and programming functions of the working parameters are accessed through the 
use of the keypad of the machine. 
Keep the “Help” (3) key pressed down to visualize the current functions of the keys in that particular 
menu or sub-menu: 
 

 

 
The keys “1” and “2” allow the selection of one of the voices of the menu. 
The “OK” (8) key confirms the choice of the menu, whilst the “Esc” (9) key is for exiting from the 
menu. 
 
Once you have entered into a specific sub-menu of visualizing and modifying of parameters the other 
keys come into use: 
 

 

 
Keys “1” and “2” allow the selection of a specific parameter. 
Keys “4” and “5” modify the current value of the parameter. It is possible to quickly select and 
modify the values keeping pressed down the relevant key. Different levels of speed will be 
progressively and automatically recalled for a quick arrival to the requested value. 
The “Def” (6) key recalls the default value of the only parameter to be modified, using the respective 
value of the last used default table (of the 3 possibilities). 
 
In each case, when the value has been modified with keys “4” and “5”, or the default value has been 
recalled, you must definitively confirm the modification of the parameter with the ”OK” (8) key. 
The attention for this confirmation is called by the “OK ?” text flashing on the display which indicates 
that the actual value memorized in the parameter memory of the machine is still not the same as that 
prepared. By pressing “Esc” (9) without confirming the parameter will not be modified. 
 
The “Copy” (7) key allows the copying of the same value to the following parameters belonging 
to the same group. For example, to set-up the same price for different products, modify the price of 
product 11, position on the following product 12 and press the key “7”. Automatically, the same price 
of product 11 will be copied and confirmed to product 12 and  automatically the position shifts to 
product 13 to continue this operation for all the following products. 
 
An analogue procedure can be carried out to contemporaneously copy the same value to all 
following parameters relative to an entire tray
. For example, once the price for product 11 has 
been modified and positioned on 12, press key “7” for at least 1”. 
The copy function as described above will be automatically repeated for all of the products of the 
current tray. At the end, the position will shift to the first product of the next tray.

Summary of Contents for LP25

Page 1: ...LP25 LP30 Cod 2850020 Rev 00 Marzo 2009...

Page 2: ...ine operation Up to more than 1700 records in text format allow the memorizing for each vend of the time and date the number of the selection the remaining and actual takings etc A progressive reading...

Page 3: ...o enter the service menu press the service key indicated in the diagram for circa 1 To return to the normal state of vending of the machine press again this key or digit on the keypad Esc 9 and confir...

Page 4: ...s 4 and 5 or the default value has been recalled you must definitively confirm the modification of the parameter with the OK 8 key The attention for this confirmation is called by the OK text flashing...

Page 5: ...of product reaches 0 days the sale of this product is inhibited Setting to Unlimited the days of the Expiry of reload of a certain product disables the management of the expiry for that product and th...

Page 6: ...rice and minimum price In particular the free price allows the selling of that product even in the absence of credit whilst the not used price disables the sale of that specific product Config product...

Page 7: ...e the temperature visualization and activate the date time visualization All of these visualizations and other eventual warning signs that can appear in particular situations appear in sequence and wi...

Page 8: ...1 up to program 16 All programs in which the time date is verified the current time date is the same or more than that of the program excepting the field Day of the week which requires the program on...

Page 9: ...the week Day of the month Month Year Hour Minute Sec Status on off 1 Monday 8 0 ON ON ON 2 Monday 16 0 OFF OFF OFF 3 Tuesday 8 15 ON ON ON 4 Tuesday 16 15 OFF OFF OFF 5 Wednesday 8 30 ON ON ON 6 Wedne...

Page 10: ...price is set at Not used are excluded from the test Test lift continually tests the lift where this option is available Test flap opens and closes continually the protection flap in the retrieval wind...

Page 11: ...ch as the turning on of the machine and all possible verifiable anomalies Registration of events is autonomous and automatic and the board is capable of memorizing more than 1700 events lines in its p...

Page 12: ...y a serial portal With an analogue procedure all texts in the various languages visualized on the display can be modified This time it is necessary to modify a text file in standard Unicode format The...

Page 13: ...SUPPLY NC 5 1 CN6 2 4 3 GND 12V COIN6 COIN5 5 PARALLEL COIN ACCEPTOR 4 2 1 10 POLES 8 9 7 6 10 3 8 6 7 9 10 COIN2 COIN3 COIN1 NC COIN4 24V NC COIN3 COIN4 GND 16 9 7 6 8 3 16 6 7 9 8 16 POLES 1 2 4 PA...

Page 14: ...Cod 2850020 Rev 00 Marzo 2009...

Reviews: