33
english
C.
Exiting from the programming mode
After you have finished programming the machine, press the button 10 (with flashing led) on brewing unit I
and all the leds will turn off. The programmed quantity of coffee will now be delivered when an automatic
brewing button is pressed.
6.12 Alarms
A flashing led on the first button of pushbutton array indicates a malfunction on the flow meter.
A flashing led on the second button of all the pushbutton arrays indicates a malfunction on the automatic
boiler refill system (jammed solenoid valve, insufficient water from the main water system, etc.). After 1’30”,
the pump motor will shut down.
Note: If the machine shuts down as described above, call your local service technician.
• Do not use water sprays, steam or similar cleaning methods. Before cleaning or mainte-
nance operations, DISCONNECT THE CABLE IF POSSIBLE; OTHERWISE, SHUT OFF
THE OMNIPOLAR MASTER SWITCH INSTALLED AHEAD OF THE MACHINE.
• If power cable is damaged, it must be replaced with the specially prepared, original
equipment replacement part which conforms to safety regulations.
• Special maintenance, parts replacement, long-term soutdown and displanting opera-
tions must be performed by LA SAN MARCO service personnel.
7. instructions for Authorized installer gas fired
Boiler (Optional)
Read the instructions before installing and using the appliance.
This appliance can only be installed and used in permanently ventilated places according to UNI-
CIG 7129 and UNI-CIG 7131 Standards.
7.1 Connection to gas supply
Position the appliance as described in the Use and Maintenance Manual, remove the control panel as de-
scribed in the same handbook, and connect the appliance to the gas supply mains, or lPG bottle (G30/G31),
using rigid metal pipes or flexible metal tubes according to UNI-CIG 9891 Standards.
Check that the appliance is prearranged for the type of gas actually being used; the corresponding setting is
shown on the settings tag.
If the appliance is prearranged for a different type of gas, change the arrangement as described in the para-
graph “Changing the calibration”.
The gas infeed, consisting of an on-off valve (51), includes a G 1/8” threaded connection (thread is not gas-
tight) according to ISO 228-1 Standard.
If using rigid metal pipes for connection to the gas supply, place an appropriate fitting between the valve and
the rigid metal pipe, which should be provided with a G 1/8” female thread (thread is not gas-tight) according
to ISO 228-1 Standard.
If using flexible metal tubes for connection to the gas supply, interpose an appropriate G 1/2” female nipple
(gas-tight thread) according to ISO 7-1 Standard and a G 1/2” male nipple (thread is not gas-tight) according
to ISO 228-1 Standard; interpose a suitable gas-tight gasket.
When the connection is completed, open the gas flow upstream of the appliance and, using a soapy solution
(never a free flame), check the perfect tightness of the connection.
7.2 Venting the combustion fumes
In relation to the venting of the combustion fumes, the appliance is of Type A1: i.e., it draws in the air required
for combustion from the room and discharges the fumes in the same environment.
Place particular attention to the volume of the room where the appliance is to be installed: this should be at
least 12 m
3
.
Summary of Contents for 85 E
Page 2: ...italiano uso e manutenzione serie 85 s e Istruzioni Originali ...
Page 22: ...21 english OPERATION AND MAINTENANCE SERIES 85 s e Translation of the original instructions ...
Page 41: ......
Page 62: ...deutsch BEDIENUNGS UND WATERTUNGSANLEITUNG SERIE 85 s e Übersetzung der Original Anweisungen ...
Page 102: ...portuguÊs UTILIZAÇÃO E MANUTENÇÃO SÉRIE 85 s e Tradução das instruções originais ...
Page 122: ...e i a à π À ƒ πƒ 85 S E Μετάφραση των αρχικών οδηγιών ...