background image

33

ENGLISH

9. Guarantee

The warranty becomes void if: 

r 5IFJOTUSVDUJPOTJOUIJTNBOVBMBSFOPUDPNQMJFEXJUI
r 5IFTDIFEVMFENBJOUFOBODFBOESFQBJSTBSFDBSSJFEPVUCZVOBVUIPSJ[FEQFSTPOOFM
r 5IFNBDIJOFJTVTFEGPSBOZPUIFSUIBOJUTJOUFOEFEQVSQPTFT
r 5IFPSJHJOBMQBSUTBSFSFQMBDFEXJUIQBSUTGSPNEJGGFSFOUNBOVGBDUVSFST
r 5IFXBSSBOUZEPFTOPUDPWFSEBNBHFDBVTFECZOFHMFDUVTFBOEJOTUBMMBUJPOOPUJODPNQMJBODFXJUIUIF

recommendations  of  this  manual,  improper  operation,  abuse,  lightning  and  atmospheric  phenomena, 
overvoltage, overcurrent, or insufficient or irregular power supply. 

10. Declaration of conformity

  

The manufacturer:

La San Marco S.p.A.

34072 Gradisca d’Isonzo (GO) Italy – Via Padre e Figlio Venuti, 10
phone (+39) 0481 967111 – fax (+39) 0481 960166 – http://www.lasanmarco.com
declares under its own responsibility that the espresso coffee machine described in this manual and iden-
tified  by  the  data  on  the  tag  located  on  the  machine,  is  compliant  with  directives  98/37/EC,  2006/95/EC, 
89/336/EEC, Regulation (EC) No 1935/2004. For verification of compliance with said directives, the following 
harmonized standards have been applied: EN 12100-1, EN 12100-2, EN 60335-1, EN 60335-2-75

Gradisca d’Isonzo, April 2009
Managing director
Mr Roberto Marri

Summary of Contents for NEW 85

Page 1: ...S 85 S E DE BEDIENUNG UND WARTUNGSANLEITUNG SERIE 85 S E ES MODO DE EMPLEOY MANTENIMIENTO SERIE 85 S E PT UTILIZA O E MANUTEN O S RIE 85 S E EL XPH H KAI YNTHP H EIPA 85 E MACCHINE CAFF ESPRESSO ESPRE...

Page 2: ...19 ENGLISH OPERATION AND MAINTENANCE SERIES 85 S E...

Page 3: ...2 Calibration of pump pressure pag 28 6 3 Calibration of water pressure in the boiler pag 28 6 4 Heating the water in the boiler pag 28 6 5 Electric cup warmer Optional pag 29 6 6 Steam delivery pag...

Page 4: ...GJYFE BOE PS NPCJMF HVBSET SFNPWFE PS XJUI UIF TBGFUZ EFWJDFT DVU PGG 5IF TBGFUZ EFWJDFT NVTU BCTPMVUFMZ OFWFS CF SFNP WFE PS UBNQFSFE XJUI 5IF QBOFMT DPWFSJOH UIF NBDIJOF NVTU OPU CF SFNPWFE BT UIF...

Page 5: ...22 ENGLISH 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 2 Exploded diagrams 19 20 Mod 85 S Mod 85 E...

Page 6: ...ever 15 Hot water spout 16 Gas burner ignition button 17 Gas burner safety button 18 Two scale pressure gauge 19 Coffee serving button 20 Visual level indicator 21 Boiler water drain tap 22 Automatic...

Page 7: ...automatic portions can be programmed on each brewing unit r PU XBUFS BOE TUFBN delivery on all models r VUPNBUJD XBUFS MFWFM boiler is automatically refilled on all models NO OF BREWING UNITS BOILER C...

Page 8: ...er softener rubber drain hose with steel coil for water drain 3 8 nipples for hose connection to water supply tube cleaning brush for serving units pump suction filter on request braided 600 mm stainl...

Page 9: ...UIF NBDIJOF UP UIF QPXFS TVQQMZ NBLF TVSF UIBU UIF EBUB PO UIF SBUJOH UBH DPSSFTQPOE UP UIF BWBJMBCMF QPXFS TVQQMZ 5IF UBH JT MPDBUFE PO UIF MFGU TJEF PG UIF NBDIJOF BOE DBO CF BDDFTTFE CZ SFNPWJOH UI...

Page 10: ...ACK BROWN YEL GREEN BLUE BLACK BROWN BLACK YEL GREEN BLUE BLACK BROWN BLACK YEL GREEN BLACK BLACK BROWN BLUE YEL GREEN BLUE BROWN YEL GREEN N L N L3 L2 L1 N L3 L2 L1 L3 L2 L1 L3 L2 L1 N L N L 1 HEATIN...

Page 11: ...sired value by oper ating on the pump screw the pressure is increased by turning clockwise it is decreased by turning counter clockwise As shown in the following figure there are three different cases...

Page 12: ...d during a coffee brewing cycle Button 10 can also be used to brew the desired quantity of coffee manually press this button to start brewing and presse the button a second time to stop brewing when t...

Page 13: ...cient water from the main water system etc After 1 30 the pump motor will shut down Note If the machine shuts down as described above call your local service technician t P OPU VTF XBUFS TQSBZT TUFBN...

Page 14: ...e is lit check through the relative hole 54 while keeping the gas knob pressed for 5 10 secon ds After this period if the flame does not remain lit repeat the ignition operation again 7 4 Changing the...

Page 15: ...perates on the valve 51 whose probe 52 must be licked by the flame from the burner 50 If the probe is not enveloped by the flame the gas flow will be automa tically shut off 2 Thermostat 59 The thermo...

Page 16: ...a overvoltage overcurrent or insufficient or irregular power supply 10 Declaration of conformity The manufacturer La San Marco S p A 34072 Gradisca d Isonzo GO Italy Via Padre e Figlio Venuti 10 phone...

Page 17: ...DPOUSPM VOJU JT defective r IFDL UIF BVUPMFWFM DJSDVJU UIF NBO ual charging button and the boiler heat exchangers r 3FQMBDF XPSO PS EBNBHFE QBSUT UP eliminate the leak r Check the wiring that feeds th...

Page 18: ...filter on unit clogged e Filter holes widened filter cup r 4QSJOLMFS GJMUFS PO VOJU clogged r PGGFF FYUSBDUJPO UBLFT B MPOH time due to clogged filter r PGGFF FYUSBDUJPO UPP GBTU EVF to clogged sprin...

Page 19: ...La San Marco S p A M X GX i c f M elk iX jZX jfeqf fi q X kXcp K c 0 0 Xo 0 0 _kkg1 nnn cXjXedXiZf Zfd dX c1 e f7cXjXedXiZf Zfd...

Reviews: