background image

Pag.46

Test actuators

- Actuators 1
- Actuators 2
- Actuators 3

-

Milk pump

- Dispenser A
- Mixer B
- Dispenser B
- Exhaust fan
- Electronic fan

Mixer A

Mixer A

Enter

Esc

Mixer test

A

0

Keep pressed the + key to
increase the speed of the
Mixer A motor . Keep
pressed the – Key to
decrase the speed.

0 -100 %

variable value

+ / -

Test actuators

- Actuators 1
- Actuators 2
- Actuators 3

-

Milk pump

-

Mixer A

- Mixer B
- Dispenser B
- Exhaust fan
- Electronic fan

Dispenser A

Dispenser A

Enter

Esc

Dispenser test

A

0

0 -100 %

variable value

+ / -

Keep pressed the + key to
increase the speed of the
Dispenser A motor . Keep
pressed the – Key to
decrase the speed.

Test actuators

- Actuators 1
- Actuators 2
- Actuators 3

-

Milk pump

-

Mixer A

- Dispenser A

- Dispenser B
- Exhaust fan
- Electronic fan

Mixer B

Mixer B

Enter

Esc

Mixer test

B

0

Keep pressed the + key to
increase the speed of the
Mixer B motor . Keep
pressed the – Key to
decrase the speed.

0 -100 %

variable value

+ / -

Test actuators

- Actuators 1
- Actuators 2
- Actuators 3

-

Milk pump

-

Mixer A

- Dispenser A
- Mixer B

- Exhaust fan
- Electronic fan

Dispenser B

Dispenser B

Enter

Esc

Dispenser test

B

0

0 -100 %

variable value

+ / -

Keep pressed the + key to
increase the speed of the
Dispenser B motor . Keep
pressed the – Key to
decrase the speed.

+

-

+

-

+

-

+

-

Summary of Contents for PLUS 5

Page 1: ...Pag 1 TECHNICAL INSTRUCTION La San Marco S p a EN ENGLISH cod 7770 046 EDITION October 2009...

Page 2: ...GRAMMABLE PARAMETERS IN ACCORDING WITH SMART CARD OR PASSWORD 13 INFO RESET 15 DOSES PROGRAMMING 19 SYSTEM MANAGER 27 MACHINE CONFIGURATION 28 MACHINE PARAMETERS 30 SYSTEM CLOCK SET UP 33 DISPLAY REGU...

Page 3: ...ion of the machine After installing the main switch and fuses see annex connect the power cord of the machine to the main switch according to the attached electrical diagram The use of adapters multip...

Page 4: ...ion 3 2 KW 24h IM 3200 W 133 33 W h 3 VENDING PHASE Delivery of No 30 cups of coffee of 100ml one cup every 2 minutes L ml 90 DV ml 2700 VM 350 W h vending phase DT 87 4 C average drink temperature EC...

Page 5: ...REFERENCE PLUS 5 1 EXIT edit Espresso 2 INS Insert blank Black coffee 3 DEL Delete character Cappuccino 4 SCROLL Latte macchiato 5 Choco 6 Mocha 7 ENTER Steam 8 ESC Hot water 9 INFO 10 SHIFT CLEAN EX...

Page 6: ...Pag 6 ELECTRIC HYDRAULIC CONNECTION 200V 1 N 50 60HZ 230V 1 N 50 60HZ 120V 1 N 50 60HZ H2O IN 1 5 Bar H2O OUT WATER SOFTNER WATER FILTRE...

Page 7: ...s to select the numbers Press Enter to confirm the numbers Enter Enter After a few seconds the display shows LCD Rev X XX ZZZZ Rev Y YY Loading REV X XXX Indicate the Software release inserted in the...

Page 8: ...the coffee spout starts dispensing water press the key dose N 1 to confirm that the filling up procedure has been carried out When the coffee boiler has been filled up the display shows Steam Coffee X...

Page 9: ...y type of Self configuration keep key n 10 shift pressed and then press key n 9 info before closing the machine front door To switch OFF the machine open the front door or place the smart card and kee...

Page 10: ...ARY OF STEAM AND COFFEE BOILER HEATING PHASE Heating element On 30 Pause Temperature sensor Please Wait Steam boiler Heating element Off ON Set up Select Drink OFF 0 C 110 C C Steam nozzle solenoid va...

Page 11: ...insert the passwords proceed as follows Turn the machine OFF Keep N 10 SHIFT key pressed for 5 seconds The display shows Enter one of the following passwords Waiter 6 1 1 1 1 Roaster 1 1 1 1 1 Owner...

Page 12: ...d light on and the machine in off WAITER SMART CARD ROASTER SMART CARD OWNER SMART CARD SERVICE SMART CARD TECHNICIAN SMART CARD if the inserted card it is correct the reader led light off Keep N 10 S...

Page 13: ...mp type X N of Dispenser Mixer X Steam boiler X Milker X Milk pump X Machine type X Remote controller X MACHINE PARAMETER Language X X Water tank X X Serial X X X Ground N X X X X X Milk pump position...

Page 14: ...X Group cycles X X SMART CARD MANAGER System code X X Credit load X X X Enable disable waiter N X X X CHANGE PASSWORD Roaster X X X X Owner X X X Service X X Technician X GROUP MANUAL MOVEMENTS Group...

Page 15: ...the number of the key XXXXX Indicates the name of the selected button YY Indicates the number of cups dispensed XXXXX Indicates the number of the SHIFT cups dispensed ZZ Indicates the number of the S...

Page 16: ...ng of the machine The total will be calculates if the selling price has been set for each dose Enter Displayed only with Self coin box configuration A2 READ DOSES DATA Reset doses counter A B Enter In...

Page 17: ...nder Cycles XX Yes No Enter If the Machine Service has been set on the display will show only the total n grinder cycles but not the relative alarm Yes No Enter Displayed only if the Service frequency...

Page 18: ...D MILKER TOTAL NUMBER Yes No Enter Enter Water filter XXXX YY ZZZZ XXXX Indicates the n of water filter liters left If the programmed n of of water filter liters exceed the display shows XXXX YY Indic...

Page 19: ...EASE NOTE TO ACCESS TO THE DOSES PROGRAMMING THE MACHINE MUST BE AT THE SET UP TEMPERATURE Press the key No 5 and No 6 to select the parameter and then press the key No 8 Enter to confirm the selectio...

Page 20: ...EE BASED DRINK NAME COFFEE SOLUBLE BASED DRINK NAME SOLUBLE UNIT BASED DRINK NAME Coffee Soluble Soluble Unit Milk Soluble Coffee Milk Soluble Latte macchiato Milchkaffee Caff latte Cappuccino Esp mac...

Page 21: ...X X PRODUCT A Water with product ml X X X X PRODUCT A Whisk speed Xx X X X X PRODUCT DENSITY A aaa gr 100ml GGG gr 100 ml X X X X PRODUCT B Water with product ml X X X X PRODUCT B Whisk speed Xx X X X...

Page 22: ...hartwall or coin mechanism B For Coffee Milk and Milk drink type the repetition cycle is not available C The Milk pump speed and Cold milk parameters will be displayed only for machine with the milk p...

Page 23: ...XXXXX YYY Press the keys to insert the price dose Press Enter key to confirm the value Enter TX Selected n button XXXXXX Button name TX Selected n SHIFT button YYY dose price Price set up Doses price...

Page 24: ...Grinders To activate the Milker and the Grinder for max 10 seconds press T1 T2 T3 T4 bottons also with the door opened Calibration MILKER GRINDER Steamed T1 G1 T2 Foamed T3 G2 T4 Enter Press key T4 G...

Page 25: ...ct Calibration MIXER A TEST 1 YY Sec 50 ml YY Sec Indicates the time to delivery 50 ml of water Enter Enter Instant Product Calibration MIXER A TEST 2 YY Sec 50 ml YY Sec Indicates the time to deliver...

Page 26: ...Pag 26...

Page 27: ...8 Esc to exit Enter Select Info reset Dose programming System manager System manager Machine configuration Machine parameter System clock programming Display regulation Service Smart card manager Chan...

Page 28: ...nser Mixer Enter Machine configuration Water tank Disable Enter Enter Use keys to enable or disable the Water tank System manager Machine parameter System clock programming Display regulation Service...

Page 29: ...Enter Enter Enter PLEASE NOTE the following functions will be displayed only if some of previous parameters machine configurations menu have been modified Enter Enter Machine configuration Milk pump...

Page 30: ...r PC cable 9600 Baud rate Decimal price and scale factor price must be set In dose program menu will be activated the relevant parameters Enter Esc MDB DEVICE Grounds Numbers 60 Variable Value 0 to 10...

Page 31: ...Enter Enter Displayed only with Self credit card configuration Multi Vending Enable Disable Token Enable Disable Enter Enter Displayed only with Self coin box configuration Esc Esc Esc The Decimal pri...

Page 32: ...ervice phone Don t change the default parameter for MODEN ATX360 2 is correct for the GSM supplied from La San Marco S p A Set a remote password to be able to connect to the machine from a remote mode...

Page 33: ...ff 1 OFF 2 OFF 3 OFF Enter Press the keys to program the machine days off Sunday Monday etc It is possible to program maximum 3 days off Press the keys to program the automatic switch ON and OFF Disab...

Page 34: ...nge the dsplay in normal mode or reverse mode Display regulation Default color Press x Press the key N 6 and N 5 to change the display colour Enter Esc Esc Esc System manager Machine configuration Mac...

Page 35: ...er cleaning program Mixer auto rinsing Milker cleaning program Milker auto rinsing Cleaning time Clean Rinse Cycle cleaning alarm Group cleaning program Group auto rinsing Mixer cleaning program Mixer...

Page 36: ...cleaning alarm Group auto rinsing Mixer cleaning program Mixer auto rinsing Milker cleaning program Milker auto rinsing Group cleaning program Water volume 100 400 ml Enter Repetitions Enter 2 5 Ente...

Page 37: ...g program Milker auto rinsing Mixer auto rinsing Milker cleaning program Clean Rinse Cleaning time Cycle cleaning alarm Group cleaning program Group auto rinsing Mixer cleaning program Mixer auto rins...

Page 38: ...ue Enter Maintenance set up Service Clean Rinse Maintenance set up Enter Maintenance set up Water filter Machine service Grinders Group cycles Water Filter Off L Service frequency Off Enter Enter Ente...

Page 39: ...spection month XXXXXX Enter Next Inspection YYYY MM DD Press if you want change the inspection day Enter Maintenance set up Water filter Machine service Group cycles Grinders Grinders Grinders Cycles...

Page 40: ...D MANAGER PLEASE NOTE A THE SMART CARD MANAGER IS DISPLAYED ONLY FOR COFFEE MACHINE WITH TRANSPONDER INSTALLED B TO CREATE A NEW CARD TECHNICIAN SERVICE OWNER ROASTER AND WAITER ITS NECESSARY USE AN E...

Page 41: ...Pag 41...

Page 42: ...ITER PASSWORD CAN NOT BE MODIFY Roaster XXXXXXX Y 0 YYY XXXXXX Indicate the user Owner Service Roaster Technician you want change the password YYYYY Indicate the password you want to change Use the do...

Page 43: ...ess the key N 1 and N 2 to move the upper piston N 3 and N 4 to move the expeller motor N 5 and N 6 to move the lower piston Enter System manager Machine configuration Machine parameters System clock...

Page 44: ...er B Dispenser B Exhaust fan Electronic fan Enter Test actuators Actuators 2 Actuators 3 Milk pump Mixer A Dispenser A Mixer B Dispenser B Exhaust fan Electronic fan Actuators 1 Actuators 1 Enter Actu...

Page 45: ...nic fan Actuators 3 Actuators 2 Enter PRESS A DOSE KEYS BETWEEN T1 TO T6 TO ACTIVATE THE ACTUATOR THAT YOU WISH TO CHECK PRESS THE SAME DOSE KEY TO STOP THE ACTIVATED ACTUATOR FROM WORKING WARNING pre...

Page 46: ...ressed the key to increase the speed of the Dispenser A motor Keep pressed the Key to decrase the speed Test actuators Actuators 1 Actuators 2 Actuators 3 Milk pump Mixer A Dispenser A Dispenser B Exh...

Page 47: ...more than one actuator at the same time b Once a time out of 5 seconds has elapsed the activated actuators will be automatically interrupted c The Milk pump speed parameter will be displayed only for...

Page 48: ...the solenoide valve of the hot water will be activated System manager Machine configuration Machine parameters System clock programming Display regulation Service Smart card manager Change password G...

Page 49: ...ystemclock programming Display regulation Service Smart card manager Change password Group manual movements Test actuators Boiler draining Preset configuration data Alarmhistory Enter Please Note a Th...

Page 50: ...guration parameters The Technician or Factory preset can be carried out only with Technician password or smart card With Service password or smart card can be carried out only the Service preset Syste...

Page 51: ...he cleaning procedure for group or whisk or milk frother follow the procedure ONLY WITH THE TECHNICIAN OR SERVICE PASSWORD Group Cleaning Off On Off Milker Cleaning Whisk Cleaning Abort cleaning ENTER...

Page 52: ...owing 1 Wrong or misconnect electric connections 2 Faulty gear motor electric 3 Faulty encoder card 4 Faulty master card 3 N 12 Upper motor error alarm H Motor error 12 This alarm is visualised on dis...

Page 53: ...irty so isolated from the water the complete filling of the boiler is checked 2 no water from mains 3 low water pressure 4 faulty motor pump 5 faulty filling solenoid valve 6 incorrect electrical conn...

Page 54: ...e coffee group solenoid valve 3 leakage from the by pass solenoid valve 6 leakage from the tubes of the coffee hydraulic circuit 7 leakage from the no return valve 10 N 37 Coffee boiler temperature al...

Page 55: ...visualised on display by code 40 Cause the flowmeter is not sending signals to the control unit within a time out of 5 seconds Result delivery continues up to a time out of 120 seconds or until the s...

Page 56: ...correct Result machine shutdown Solution 1 Carry out PRESET CONFIGURATION DATA procedure 2 Insert new software by means of P C 14 N 63 Clock error Clock error 63 This alarm is visualised on display by...

Page 57: ...litres of previously programmed water which may be dispensed Result none Solution renew the softener salts To cancel the alarm see the Info Reset paragraph for further information Note this alarm doe...

Page 58: ...eam at a pressure lower than 1 7 bars 24 Steam boiler Klicson cutoff No messages on the display Cause The temperature of the boiler has reached the limit of 145 C Result the steam boiler heating is in...

Page 59: ...g screw to adjust the coffee dispensing pressure 8 9 Bar max clockwise to increase it and anti clockwise to decrease it The pressure will be shown on the gauge PIC A PIC B 2 Calibrating the coffee gri...

Page 60: ...regulator rightwards to get a finer degree and leftwards to get a coarser degree PIC A 3 Calibrating the flow adjustment of the coffee outlet In order to calibrate the dispensing speed and change the...

Page 61: ...group pistons Parts to be cleaned or replaced check and decide on site 4 o rings for the drip tray 5 group upper piston micro screen 6 group lower piston screen 7 milk frother 8 clean the hopper by t...

Page 62: ...users in the european community Pursuant to European Directive 2002 96 EC on electrical waste WEEE users the Europ an community are advised of the following The symbol with the crossed out dustbin on...