Display
board
22
Lower zone (15 to 20 °C)
Press once the button
to select the lower area of the basement. Press a second time the same
button to increase / decrease the temperature by 1 degree Celsius or Fahrenheit. This zone is
programmed to be cooled between 15 and 20 ° C.
Scrowling menu
If the displayed temperature is 20 ° C, by pressing once on the same button, the display will change to
15 ° C.
NB: The display shows the desired temperature. After 10 seconds, it automatically switches to the
actual temperature inside the cellar until the desired setting.
Malfunctions
« HH »:
High temperature alarm: T1≥30 ºC and lasted two hours the temperature alarm buzzer,
frequency 1Hz, digital display "HH"
,
it will become normal once T1
≤
29 ºC, alarm could be stoped
immediately by pressing on/off switch or removing the plug.
« LL »:
Low temperature alarm: T1≤2 ºC and lasted half hour the temperature alarm buzzer, frequency
1Hz, digital display "LL"
,
it will become normal once T1
≥
3 ºC, alarm could be stoped immediately by
pressing on/off switch or removing the plug.