Installation
-
Programming_Sectional doors_Intellidrive 400_N°7132
This document is the exclusive property of FTFM La Toulousaine and must on no account be copied. The document may be modified at any time in accordance with product changes.
06/19
p.10
IMPORTANT :
In the case of connection of a control member or safety device, it is imperative
to perform an apprenticeship to make the entries 22/23/24/25/26 functional.
See chapter :
Learning of the run
.
"Maintained pressure" mode (default)
(maintained mounted/descent)
Putting the cabinet into operation
Control before any programming :
Door should be perfectly compensated and balanced.
Press x1
(LED lights up)
Electrical cabinet under power
Determining the direction of rotation
-
Position the door at mid
-
height, using the emergency maneuver.
-
Press continuously, if the door closes, invert the feeder wires of motor
at terminals 10 and 11.
Opening
Press continuously
Until rearward stop
(by dropping the arrow, the door stops)
Closing
Press continuously
Until to the ground
(by dropping the arrow, the door stops)
Display on the LCD screen :