background image

Endurance User's Information

Page 5

SECTION 1.
Caring For Your Endurance

Your Endurance will require very little

maintenance. However, as with any fine appliance,
there are certain steps you should take to insure
continuing optimum performance.

1A. General Care

Keep your Endurance area clear and free from

combustible materials, gasoline and other flammable
vapors and liquids.

If you desire, clean the jacket surfaces with a

damp cloth and mild soap. Do not use flammable
cleaning materials.

Keep vent terminal free of obstructions. Do not

pile snow against vent terminal.

1B. Annual Inspection of Flues and Vents

You should visually inspect the vent pipe once a

year. Should any corrosion exist, have the affected
parts replaced.

On horizontally vented units installed with

p/n 2400-009 (Direct Vent Kit) inspect the metal vent
terminal (see Figure 3) on the outside of the building
for corrosion. Replace if necessary.

On all models installed without the Direct Vent

Kit, clean and inspect the condensate collection and
disposal system which is a part of the flue assembly.

1C. Shutting Down the Endurance

The need may arise to shut down your Endurance

(extended stay away from home, for example). If so,
the following steps are required:
1.

Switch off main disconnect switch (located on
back of control panel).

2.

Close gas shutoff valve above combination gas
control valve (inside unit).

3.

Close main manual gas valve.

4.

If freezing is anticipated, drain Endurance and
be sure to protect building piping from
freezing, also.

The above steps may require qualified service

personnel.

1D. To Restart Endurance

Should the need arise (power interruption, for

example), you may have to restart your Endurance.
Follow these steps:
1.

Depress the reset button on the top of the control
panel for at least one second, and then release.

2.

Turn up thermostat to call for heat.

3.

In approximately 2 seconds, the blower will
operate and ignition should occur after 35-40
seconds. It may take as long as 2½ minutes.

4.

If ignition does not occur, wait 5 minutes and
then repeat steps 1 through 3.

5.

If, after three attempts, you still are unable to
achieve ignition, shut down the boiler and call
your service technician.

If drained, follow these steps:
1.

Follow “Installation Manual” for proper filling
and purging.

2.

Turn on main manual gas valve.

3.

Remove control access panel and top front cover
and turn on gas shutoff valve, above combination
gas control valve.

4.

Switch on main disconnect switch, depress on/
off button on front of control panel, and depress
black reset button on top of control panel (pump
and blower will start and igniter will be
energized, after 35 seconds the gas valve will be
energized, and ignition will occur). If ignition
does not occur within 2½ minutes switch “off”
main disconnect switch, wait 5 minutes and
switch “on” again. If after three attempts ignition
does not occur, initiate shutdown procedure and
call for service.

1E. In the Event of Power Failure

The Endurance cannot be operated during an

electrical power outage. If there is an extended power
outage with danger of freezing, then the Endurance
(and all other water systems) should be completely
drained. When draining the unit, turn off gas and turn
off the main power switch. When replacing in service,
refer to start-up instruction for proper filling and
purging.

1F. Full Service Every 3 Years

In addition to the annual visual inspections by

the homeowner, a qualified service agency should
conduct a detailed inspection of all flue product
carrying areas of the boiler and vent system. This
should be done in accordance with the service
instruction in the “Installation and Operating
Instructions Manual” for the Endurance.

Caution

Do not use this boiler if any part has been under
water. Immediately call a qualified service
technician to inspect the boiler and to replace any
part of the control system and any gas control
which has been under water.

WARNING

Should overheating occur or the gas supply fail to
shut off, do not turn off or disconnect the electrical
supply to the pump. Instead, shut off the gas supply
at a location external to the Endurance.

En cas de surchauffe ou si l’admission de gaz ne
peut être coupée, ne pas couper ni débrancher
l’alimentation électrique de la pompe. Fermer plutôt
le robinet d’admission de gaz à l’extérieur de
l’appareil.

Summary of Contents for EBP Series

Page 1: ...les instructions données dans cette notice pour réduire au minimum le risque d incendie ou d explosion ou pour éviter tout dommage matériel toute blessure ou la mort Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareils Ne touchez ...

Page 2: ...TION 1 Caring For Your Endurance 1A General Care 5 1B Annual Inspection of Flues and Vents 5 1C Shutting Down the Endurance 5 1D To Restart Endurance 5 1E In the Event of Power Failure 5 1F Full Service Every 3 Years 5 1G Trouble Shooting Fault Codes 8 ...

Page 3: ... to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance 4 This appliance is equipped with an ignition device which automatically lights the burner Do not try to light the burner by hand 5 Removecontrola...

Page 4: ...e plancher QUE FAIRE EN CAS D ODEUR DE GAZ N essayez pas d allumer n importe quelque appareil que ce soit Ne touchez pas à un commutateur électrique N utilisez pas le téléphone de votre résidence Appelez immédiatement votre fournisseur de gaz en utilisant le téléphone de votre voisin Suivez les instructions de votre fournisseur de gaz Si vous ne pouvez joindre votre fournisseur de gaz appelez le s...

Page 5: ... 3 5 If after three attempts you still are unable to achieve ignition shut down the boiler and call your service technician If drained follow these steps 1 Follow Installation Manual for proper filling and purging 2 Turn on main manual gas valve 3 Remove control access panel and top front cover and turn on gas shutoff valve above combination gas control valve 4 Switch on main disconnect switch dep...

Page 6: ...LAARS HEATING SYSTEMS Page 6 Figure 1 EBP Assembly View Figure 2 EDP EDN Assembly View Figure 3 Vent Terminal Outside Wall Vent Terminal Gas Shutoff Valve Gas Shutoff Valve ...

Page 7: ...ge Reset Button Return Supply Heating Systems Fittings Main Disconnect Switch Field Wiring Box Relief Valve Gas Supply Manual Main Shutoff Domestic Hot Water Connections Drip Leg Cap Front View Side View Rear View Removable Front Cover Temperature LED Display Removable Control Access Panel Reset Button Heating Systems Fittings Return Pressure Gauge Supply Manual Main Shut Off Drip Leg Cap Relief V...

Page 8: ...er Control Fault Codes F1 Boiler control internal error Switch off boiler and restart If F1 repeats replace boiler control F3 Gas valve status is on with no call for heat This is an indication of a wiring error or a seized relay Check relay first and then boiler wiring F4 Supply sensor error Check for damaged wiring or poor connection first Check sensor resistance per installation manual F5 Tank s...

Reviews: