User’s Manual - The FT Series Wall Mounted, Combination Boiler

Page 3

CH Supply

CH Return

CH Supply CH Return

Combustion Air

Vent

CH Supply CH Return

Combustion Air

Vent

FTCW140

FTCW199

#

    Name of Component

1

Air Vent (air eliminator)

2

Pressure Relief Valve

3

Air Intake Collar

4

Air Gas Mixing Pipe

5

Gas Valve

6

DHW Water Tank

7

Main PCB

8

Manual Power Switch (ON / OFF)

9

Boiler Pump

10

'CH' Supply Connection

11

'CH' Return Connection

12

CH Pressure Gauge

13

DHW Outlet Connection

14

Gas Inlet Connection

15

DHW Inlet Connection (filter and flow restrictor)

16

Condensate Connection

#

    Name of Component

17

Condensate Trap

18

Blocked Condensate Switch

19

Mixing Valve

20

Terminal Block

21

Control Panel and Display

22

Heat Exchanger

23

Ignition Transformer

24

Flame Detecting Sensor

25

Burner Case

26

BLDC Fan (Blower)

27

Vent Pipe

28

 Air Pressure Sensor

29

Vent Pipe Collar

30

Sight Glass

31

Low Water Cut Off

32

Overheat Temperature Sensor

Summary of Contents for FT Series

Page 1: ...h could cause serious injury property damage or death Improper installation and or operation will void the warranty AVERTISSEMENT Assurez vous de bien suivres les instructions donn es dans cette notic...

Page 2: ...proper ventilation of interior components Do not obstruct or block a free flow of air to the boiler to ensure proper ventilation If desired clean the jacket surfaces with a damp cloth and mild deterg...

Page 3: ...9 Boiler Pump 10 CH Supply Connection 11 CH Return Connection 12 CH Pressure Gauge 13 DHW Outlet Connection 14 Gas Inlet Connection 15 DHW Inlet Connection filter and flow restrictor 16 Condensate Con...

Page 4: ...age Temperature Range of 20 to 80 C Buttons Function Method Function Method A Display Power Turns Control Display ON OFF Press Tap B Modes Status Display Mode With display power on Press Hold 5 Second...

Page 5: ...y to display all parameters DHW mode Combination boiler Set Point can be adjusted Outside temp or 0 10 V mode Operating by outside temperature or 0 10V Numeric Display Domestic Hot Water Mode Anti Fre...

Page 6: ...hrough a Start Up checklist and briefly show a sequence of diagnostic codes before entering into the Operating Mode It will then display the following information Indicate Example Current Operating Te...

Page 7: ...ture Current Overheat temperature L rt 1 PH Burner Operation Time Supply power time Supply power time x 100 hour 2 rh Burner operation time Burner operation time x 1 hour 3 rH Burner operation time Bu...

Page 8: ...nt changes and to Exit Indicate Example Current DHW set point temperature 120 F Temperature sign Celsius or Fahrenheit letter C or F If display is communicating with the main controller normally the c...

Page 9: ...it When the button D is pressed for more than 5 seconds temperature unit will toggle between C and F To activate heat storage function First turn OFF the power to the Control Display Then Press and Ho...

Page 10: ...Page 10 Notes...

Page 11: ...User s Manual The FT Series Wall Mounted Combination Boiler Page 11 Notes...

Page 12: ...ut notice in accordance with our policy of continuous product improvement Customer Service and Product Support 800 900 9276 Fax 800 559 1583 20 Industrial Way Rochester NH USA 03867 20 10 Document 148...

Reviews: