Page 16
open
Before Operation
1. Check the Gas Type (NG/LP)
When using or moving the unit for the first time, check
if gas type matches with the gas type of the Boiler.
Check whether the gas type which is supplied is NG
(Natural Gas) or LP (Propane) and also check the
Boiler gas type. The gas type is indicated on the rating
plate on side of the Boiler.
2. Check the Power (120V 60Hz)
Check that the appliance is connected properly.
3. Check the Cold Water
Inlet valve. Please keep the
appliance water inlet valve
open at all times. The appliance
will not ignite when insufficient
water or no water is in the
heating pipes. (valve: always
open position)
4. Check the Gas Valve
Check that the manual gas shut-off valve
that supplies the FT is opened.
5. Check the area around the appliance and remove
any combustible or flammable materials. Remove
laundry or any other items that are on or near the
boiler or vent pipe.
When in Operation
CAUTION
1. Caution for Gas leak
Frequently check for a gas leak at the gas connection
portion with soapy water.
Steps to take if you have a Gas leak.
1. Shut down the boiler as soon as gas fumes are
detected.
2. Close the intermediate gas valve.
3. Open windows for ventilation.
4. Call a qualified service technician for immediate
repair.
2. Caution for Ventilation
Make sure that there is sufficient inflow and outflow of
air ventilation while using the unit.
If the ventilation is improper, combustion quality may
deteriorate inside the appliance and cause shortened
life of the appliance.
3. Burn Warning
Be careful not to burn yourself on the flue or pipes. They
become extremely hot during operation.
3.2
Safety Precautions and Proper Use