48
NOTICE
The default temperature setting displayed for commercial controls that will appear when the water
heater is first connected to the electrical supply or in the event of a power interruption is 140
°
F.
In most situations, the Main Control on the water heater will suit the customer’s needs and reduce the
installation time required. If a remotely located temperature control is desired, a Remote Control (239-
44509-00) may be purchased from your supplier. When deciding on the best location for the remote
control, please consider the following items:
1. Place the control out of reach of small children.
2. Avoid locations that may allow adjustment by unauthorized personnel (see above warning).
3. Avoid locations where the control will become hot, such as over the stove, near the oven, or other
heat sources.
4. Avoid direct sunlight. (The digital readout can be difficult to read in direct sunlight).
5. Avoid areas where the remote can be splashed with cooking water, oil, or sauce.
6. The remote control operates with low voltage, 12 volts DC.
Remote Main Control Installation (Optional):
Follow the same control installation procedure as outlined under “Temperature Control Installation” for
residential models. Up to two remote temperature controls can be installed.
WARNING
Do not attempt to connect the remote controls with the power on to the water heater. There is 120 volt
terminals and wiring next to the remote control connections inside the unit. All servicing and wiring must be
performed by a qualified installer.
Remote Control Wiring Connections Inside Water Heater
Figure 46
INITIAL OPERATION AND TESTING OF CONTROLS (INSTALLER ONLY)
1. Turn on power to the water heater and fully open a hot water tap.
2. Check the operation of the water heater. Check the operation of the remote temperature
control(s). Check the operation of the power failure protection system (drain solenoids).
3. Explain the proper operation of the new
Laars
EVERHOT
®
water heater to the
customer.
Summary of Contents for IGI-180C-5N
Page 7: ...7 EVERHOT IGI Model Series Dimensions Figure 1...
Page 14: ...14 Recommended Piping for a Basic Installation Figure 2...
Page 15: ...15 Recommended Piping for a Circulation System Figure 3...
Page 35: ...35 Horizontal Vent System Installation examples Figure 36...
Page 38: ...38 Vertical Vent System Installation examples Figure 40...
Page 39: ...39 Cut Line Template Figure 41...
Page 44: ...44 Wiring Diagram Schematic Figure 43...
Page 59: ...59 Schematic Diagram of Internal Parts Figure 53...
Page 61: ...61 Internal Components...
Page 62: ...62 Internal Components...
Page 63: ...63 Electrical Components...
Page 67: ...67 NOTES...