51
Maintenance Schedule
WARNING
Water heaters are heat producing appliances. To avoid damage or injury there must be no
materials stored against the water heater or vent-air intake system, and proper care must be
taken to avoid unnecessary contact (especially by children) with the water heater and vent-air
intake system.
UNDER NO CIRCUMSTANCES SHOULD FLAMMABLE MATERIALS, SUCH
AS GASOLINE OR PAINT THINNER BE USED OR STORED IN THE VICINITY OF THIS
WATER HEATER, VENT-AIR INTAKE SYSTEM OR IN ANY LOCATION FROM WHICH
FUMES COULD REACH THE WATER HEATER OR VENT-AIR INTAKE SYSTEM.
IMPORTANT
The water heater should be inspected at a minimum annually by a qualified service technician
for damaged components and/or joints not sealed.
DO NOT
operate this water heater if any part
is found damaged or if any joint is found not sealed.
Following are the instructions for performing some of the recommended maintenance.
Unit inspection and adjustment should only be performed by a qualified technician.
Table 7
– Suggested Maintenance Schedule
Service Interval
Component
Operation
Action
1 Month:
Tank
Sediment removal
Drain off several gallons of water.
Condensate Line
Inspect & clean
Clear drainline and trap, verify proper pitch.
1 Year:
Powered Anode
System
Check LED/inspect
rods
1st year: check rods to determine service
interval; check LED annually.
Relief Valve
Function test
Operate lever, inspect for blockage or
corrosion.
Vent & Air Intake
System
Inspect
Inspect joint seals/vent supports; clean air
filter accessory kit if used.
Vent Terminals
Free of blockage &
debris
Clear intake and exhaust terminals, clean
terminal screens.
Combustion System
Inspect & clean
Clean flame sensor, igniter, & inspect burner.
Flushing Water Heater
1. Turn OFF the water heater electrical disconnect switch.
2. Open the drain valve and allow water to flow until it runs clean.
3. Close the drain valve when finished flushing.
4. Turn ON the water heater electrical disconnect switch.
Filling the Water Heater
1. Close the water heater drain valve. This water
heater utilizes a ball valve; when closing the
valve, the stem will spin indefinitely. Confirm it
is closed by ensuring the slot on the stem is
perpendicular to the valve body. If alternative
water connections are provided but not used,
make certain they are plugged (i.e. space
heating & alternate top connections).
2. Open the cold water supply shut-off valve.
3. Open several hot water faucets to allow air to escape from the system.
4. When a steady stream of water flows from the faucets, the water heater is filled. Close the faucets and
check for water leaks at the water heater drain valve, combination temperature and pressure relief valve
and the hot and cold water connections.
Summary of Contents for LUHE120T