Mascot FT Floor Standing Combination Boiler
Page 53
5.4 Status Display Mode
SECTION 5. Control Display and Operation
Digital Display
Status Display Parameter
Description
O:ot
Outdoor temperature
Current Outdoor temperature
A: Li or A: GA Flow unit
Current flow value(Li: L/m, GA: GPM)
b: It
CH Return Water Temperature Current Return Water Sensor Temperature
C: Fr
Fan rpm
Current fan rpm value
d: Lc
Lock mode
Lock mode ON/OFF
E: oP
OP temperature
Current OP temperature
F: dH
DHW temperature
Current DHW temperature
H: Eh
Exhaust temperature
Current Exhaust temperature
I : St
Storage Temperature
Current Storage Temperature
J: oH
Overheat temperature
Current Overheat temperature
L: rt
1: PH
Burner
Operation
Time
Supply power
time
Supply power time x 100 hour
2: rh
Burner
operation time
Burner operation time x 1 hour
3: rH
Burner
operation time
Burner operation time x 1,000 hour
4: It
Ignition cycles
Ignition cycles x 10 times
5: IH
Ignition cycles
Ignition cycles x 10,000 times
P: Ou
Displays output condition for
internal primary pump and
three way valve.
- Off
- On
1st Icon
2nd Icon
3rd Icon
Internal
Pump
CH
Pump
Not Used
To change any of the above listed Status Parameters,
Press and Hold Button B
to get into the Status Display Mode.
Rotate Dial E until you find the Parameter that you wish to change. Tap Dial E to enter that Parameter.
All other modes except d:Lc (Lock mode) are to display current status, therefore you need to check the
current setting and press button to exit.
Summary of Contents for MFTCF140
Page 48: ...LAARS Heating Systems Page 46 4 19 Control Board Electrical Diagram SECTION 4 Installation...
Page 65: ...Mascot FT Floor Standing Combination Boiler Page 63 6 2 Fault Tree Analysis 1 Flame detection...
Page 75: ...Mascot FT Floor Standing Combination Boiler Page 73...
Page 78: ...LAARS Heating Systems Page 76 Heat Exchanger MFTCF140...