Installation 

Storage Instructions 

NOTICE! Keep Electric Tankless Water Heaters stored in original packaging until installation. 

Recommended storage criteria:  

Store Electric Tankless Water Heaters where temperatures exceed 35°F (2°C) at all times. 
Indoor storage is recommended. 
Minimize excessive on-site transport to reduce risk of shock and impact damage.  

Alternate storage:  

If in the original crate, Electric Tankless Water Heaters will withstand outside storage for approximately 1 month in most 
climates. The crate may not be capable of protecting the heater if left outside longer than this time frame. 
If the Electric Tankless Water Heater is stored in an outdoor environment, care should be taken to protect the heaters 
from:  

• Rain or other falling precipitation via tarp or other waterproof media
• Runoff and accumulation o

f groundwater from any source that may exceed 1 inch (25mm).

NOTICE! 

For heaters with ENHT freeze protection option(s): External plumbing to the heater(s) on a

n N 

Series Skid

 

(C Series)

 are

 

not freeze protected from the factory and on-site installation of freeze protection is the sites 

responsibility. 

NOTICE! 

For heaters with ENHT freeze protection option(s): If the heater is stored where the temperature could 

fall below 45°F (7°C), the heater must be powered immediately after hydro testing to ensure internal freeze 
protection components are activated. Once the heater is installed and the on-site plumbing has been hydro tested, 
the power supply must remain constant until the risk of freeze is eliminated. If this is not possible, the heater must 
be drained. Freezing of the heater can cause serious damage. Follow notes in Start Up Check List section following 
an electrical lockout/tagout procedure.

Packaging 

Crates are constructed from 3/4" (19mm) OSB. 
Crate dimensions approx: 48" x 60" x 100" (1219mm x 1524mm x 2540mm) 
Crates should not be stacked. 
Safety issues related to packaging:  

Product should be transported with the care associated to packages labeled “FRAGILE” even if packaging is not

marked accordingly.

Standard safety procedures for forklift transport and large items less than 2000lbs (907 kgs) should always be
followed.

When stored, crate must be supported in entirety of its length and width.

4

Summary of Contents for N Series

Page 1: ...s Tankless Heater Models LCTEC216 2x LCTEN108 LCTEC252 2x LCTEN126 LCTEC288 2x LCTEN144 Voltage options for models 600V Three Phase 480V Three Phase 415V Three Phase 400V Three Phase 380V Three Phase...

Page 2: ...shed and then completely turned off before beginning installation Debris in supply lines can cause valves to malfunction CAUTION Hot pipes DO NOT touch May cause burns NOTICE These heaters DO NOT prov...

Page 3: ...Specific Requirements The N Series Skid C Series can be used in many different applications that require custom tuning for specific applications to maximize performance of the heater For use in a re c...

Page 4: ...freeze protected from the factory and on site installation of freeze protection is the sites responsibility NOTICE For heaters with ENHT freeze protection option s If the heater is stored where the t...

Page 5: ...pment intended to be used to transport the system Remove the shipping crate top and sides Locate the forklift tubes on the skid system and lift for transport NOTICE During transit transport close to t...

Page 6: ...for service and maintenance of the cabinet enclosure and a minimum of 48 1219mm above the top of the cabinet enclosure is needed Verify skid system is in final installation location Secure the base to...

Page 7: ...ate or Ball Type Valves Elbows nipples and fittings as needed Components included in the N Series Skid C Series Systems are different from the standard N Series Heater See dimensional drawings for ref...

Page 8: ...Installation 8 68 1734 69 1759 80 2035 81 2065 80 2035 81 2065 N Series Skid C Series Dimensions 3 Plumbing Installation Cont...

Page 9: ...ly following the union No valve or restriction is between the relief valve and the system or the relief valve and drain Shutoff valve is installed after pressure and temperature relief valve on outlet...

Page 10: ...aars com Technical Support Website Email 603 335 6300 or Toll Free 800 900 9276 www laars com For field service please contact your professional installer or local Laars sales representative United St...

Reviews: