Main connections 

 

Connect a High-Grade Power cable to the IEC input and to your wall socket. Make sure that your wall 
socket provides a good ground before connecting the power cable

.

 You must supply 230 to 240 Volt 

AC/  50Hz  (115 to  120  AC  Volts  / 60Hz).  (Every 

suono

  is tuned  and  calibrated  using  the 

Lab12 Knack 

mk2 Power Cable

. We strongly suggest using this cable). 

 

Connect to your Preamplifier 

 

Connect the preamplifier analog output to the analog line level input of your suono Power Amplifier. 
Make sure about the correct channel connections. We suggest using a good quality interconnect cable 
pair. 

 

Connect your Speakers 

 

Connect your speakers to the additional output of suono (connect speakers from 2 to 4 ohm at 

4ohm

 

positive bind, speakers from 6 to 16 ohm at 

8ohm

 bind). Make sure about the phase and polarity of 

speakers, 

always  connect  ‘’plus’’

  (red)  bind  of  suono 

to  ‘’plus’’

  (red)  bind  of  speaker  and  same  with 

black.

 

 

Notes:   

 

You  can  choose  the  operation  of  suono  between  triode  or  Ultra  Linear  pentode  mode,  to  tune  the 
sound closest to your taste. 
This  can  be  done  through  two  toggle  switches  on  the  back  of  power  tubes.  Position  both  switches 
towards to transformers for Triode mode or towards to tubes for Ultra Linear pentode mode. 

Always do this selection with your amplifier turned off

 

Suono is fully compatible with the best octal tubes (6550, KT88, KT120). You can use any of these three 
types  of  tubes  with  no  problem. 

Please  always  set  correct  bias  after  any  tube  change,  always  use 

matched pairs of tubes (contact Lab12).  

 

 
Bias Setting 

 

Bias board is located inside the amplifier. You have to unscrew the amplifier to reach 
this board. You will also need a DC voltage meter to make adjustments. Please come 
in contact with a qualified person or your local dealer if you are not sure about this 
procedure. 
After changing tubes, always turn the two 

bias trimmers’ clockwise (cold bias

) with a 

3mm screwdriver, before turning on the amplifier. Wrong bias will destroy your tubes 
and  possibly  your  amplifier.  Always  adjust  tubes  bias  current  immediately  after 
turning on. Repeat bias procedure at least 3 times the first 5 hours of using. 

Summary of Contents for suono

Page 1: ...Owner s Manual suono 25W Class A Single Ended Power Amplifier www lab12 gr manual v1 6 ...

Page 2: ...lifier Page 2 of 9 Table of Contents It is yours Unpacking and warnings Features Installation Placement Suono Tubes Position Front Panel Rear Panel Main connections Bias Setting For the safety of your equipment Specifications 3 3 4 4 5 6 7 8 8 9 9 ...

Page 3: ...forget that your suono is totally handcrafted with perfectly matched parts of the finest selections In order to reach the optimal performance your suono needs at least 150 hours of listening In this time all components go from burn in period to stable Before setting up your new suono we encourage you to thoroughly read this manual to properly acquaint yourself with its features We love music and a...

Page 4: ...ld compromise suono s performance and reliability Carefully put the tubes in dedicated sockets Make sure that the tubes are perfectly snap into sockets See bellow page Due to high power tubes design suono s chassis could be hot so you should never place another hot component directly near this device Make sure that the device has enough space to ventilate Tubes will be hot this is normal Be carefu...

Page 5: ...Positions Insert the tubes carefully in each position All tubes are marked with position number was placed during calibration and burn in of suono All in box tubes are perfectly matched during calibration to achieve a perfect balanced operation V1 KT150 V2 KT150 V3 6n2p V4 6n2p ...

Page 6: ... and two VU meters The three LEDs C indicate that the device is powered on To the left of the 3 LEDs you will see a retro analog VU meter A You can accurately monitor the output level of left channel on dB scale To the right of the 3 LEDs you will see a retro analog VU meter B You can accurately monitor the output level of right channel on dB scale ...

Page 7: ...ou will find an IEC AC input Below IEC input A the main fuse holder B and the Power switch C are located A pair of RCA connectors F is located about in the middle of the back panel It is the input of the signal from your preamplifier Bellow signal input you can find the speaker outputs D E You have the choice of 4 or 8 ohm output for perfect matching with your speaker impedance ...

Page 8: ...oose the operation of suono between triode or Ultra Linear pentode mode to tune the sound closest to your taste This can be done through two toggle switches on the back of power tubes Position both switches towards to transformers for Triode mode or towards to tubes for Ultra Linear pentode mode Always do this selection with your amplifier turned off Suono is fully compatible with the best octal t...

Page 9: ...s possible to damage tubes or even output transformers Specifications Power 230VAC 50Hz 115VAC 60Hz Power consumption 350 VA max Output power 25 Watt per channel KT 150 Frequency response 20 Hz 25 KHz 0 9dB Input impedance 100K ohm Recommended speakers 4 8 ohm Tube complement 2x 6n2p dual triodes 2x KT 150 Power Pentodes Input sensitivity 600mV triode mode 500mV Ultra Linear mode Inputs 1x line st...