background image

                                  ULTRASONIC CLEANER 

 

4.

 

Cleaning Method 

A.

 

Direct Cleaning 

i.

 

It is to clean the works directly by putting the works in bath. It is easy 
and good detergency. 

ii.

 

Pour Cleaning solution up to the indication line(When works are put) 

iii.

 

Put the works in the perforated Basket or Pallet, and put it in the 
bath. And then Ultrasonic ON. 

iv.

 

Put the works in the bath hung on wire or string. And then Sonic ON. 

v.

 

After cleaning, you need to rinse the works away with water to keep 
clean. Because the residue is remained in the bath. 

vi.

 

High concentrations of acid, alkaline cleaning solution may corrode 
the internal surface of the tank. 

B.

 

Indirect Cleaning 

i.

 

It is to clean the works put in the beaker in the bath. The inspection 
of cleaning result, filtering and disposal are simple. 

ii.

 

Pour water up to the indication line.(When the beaker are put) 

iii.

 

Pour the solution to a beaker or several one containing the works. 

iv.

 

Put the beaker containing the works in the bath and clean it. 

v.

 

When putting the beaker in the bath, take care that not to enter 
water into the beaker by ultrasonic wave. 

C.

 

Effective Cleaning 

i.

 

Pour cleaning solution up to indication line. (When the works are put) 
Or otherwise, it causes overheat of heater. 

ii.

 

Put the works in the basket or pallet in the bath. Using the basket or 
pallet is easy to put or take out. 

iii.

 

Temp. of solution in the bath is proper at 40℃. (except for UCP-02) 

iv.

 

Do not use the highly Volatile Solution.(ex, Solvent, Thinner etc.) 

v.

 

Strong acid, strong alkali solution should be avoided because it may 
cause corrosion. 

vi.

 

After cleaning, rinse well in water, allowed to dry out. 

vii.

 

After using the Ultrasonic Cleaner, discharge the solution through the 
drain, rinse with clean water and wipe clean with a towel or tissue.   

DOMINIQUE 

DUTSCHER SAS

Summary of Contents for UCP-02/10/20

Page 1: ...ULTRASONIC CLEANER OPERATING MANUAL ULTRASONIC CLEANER Model UCP 02 10 20 UCS 05 10 20 D O M I N I Q U E D U T S C H E R S A S...

Page 2: ...Series B UCS Series 3 Operation 8 A Function Key B Starting Method 4 Cleaning Method 10 A Direct Cleaning B Indirect Cleaning C Effective Cleaning 5 Trouble Shooting 11 6 Warranty 11 7 Membrane 12 A U...

Page 3: ...nual marks following warning indication for you to do not hurt and for property to do not damage Ignore this expression and user makes contents that danger of death or serious injury can happen in cas...

Page 4: ...the bath Otherwise it may cause the damage to the cleaner Do not operate the cleaner with wet hands Make sure of pouring solution up to the indicating level Otherwise it may cause the overheat of heat...

Page 5: ...r is being supplied Otherwise it may result in electrical shock Make sure of using the plug connected to the ground Do not clean with placing the works directly on the bath bottom Use a basket or a tr...

Page 6: ...2x104 Overall Size WxDxH 490x368x297 721x451x297 290x240x200 Temp Range Amb 70 Time Range 1 99 min 4 hour 1 99 min Transducer BLT Type Ultrasonic Freq 40 KHz Input Power AC230V 50 60Hz or AC120V 60Hz...

Page 7: ...Heater Power 150W 190W 320W Ultrasonic Freq 40 KHz Input Power AC230V 50 60Hz or AC120V 60Hz Temp Range Amb 70 Time Range 1 99 min 4 hour Body Material SUS 304 Control Microcontroller Control Method...

Page 8: ...peration of Heater is displayed as DOT LED on FND TEMP window Display whether to operate DeGAS Display whether to generate ULTRASONIC KEY SET KEY Operated as NORMAL TEMP TIME OP MODE POWER NORMAL Sele...

Page 9: ...changing into Operation Selection Mode UP DOWN Key to select the proper mode can be used OPERATION SELECTION MODE viii In OPERATION SELECTION MODE press SET KEY once more again and then goes into POW...

Page 10: ...e indication line When the beaker are put iii Pour the solution to a beaker or several one containing the works iv Put the beaker containing the works in the bath and clean it v When putting the beake...

Page 11: ...Check Time Set 2 Request A S Cleaning power is weakened 1 Solution is old pollution level is high 2 Solution is insufficient 3 Residue on bath bottom is solidified 4 The works are too much put in the...

Page 12: ...ULTRASONIC CLEANER 7 Membrane A UCS Series D O M I N I Q U E D U T S C H E R S A S...

Page 13: ...ULTRASONIC CLEANER B UCP Series D O M I N I Q U E D U T S C H E R S A S...

Page 14: ...d Kingdom Tel 44 1865 400321 E mail labcompanion medlinescientific com FAX 44 1865 400736 China Shanghai Branch A 2113 Oriental International Plaza 85 LouShanGuan Rd Changning District Shanghai China...

Reviews: