C Series Operation Manual  

7

avoiding a poor signal-to-noise ratio. This gain adjust-
ment feature makes it easier to achieve an optimal 
balance between headroom and noise floor.

4..3  Voltage Peak Limiting 

The Voltage Peak Limiting (VPL) feature allows user 
adjustments that determine maximum voltage output, 
thus matching the amplifier to the connected speaker 
load. Whether the connected load is low impedance 
(8, 4 or 2 ohms) or high impedance (70 V / 100 V), 
the VPL feature can be set to ensure that neither 
temperature nor current limitations are exceeded 
before reaching the desired voltage threshold. 

4..4  Protection and performance  

optimization 

Appropriate and reliable power amplification is vital 
to any audio system. Inadequate or faulty power  
amplification could cause damage to the loudspeakers, 
or in some cases to the power amplifiers themselves. 
To prevent any damage or costly service interrup-
tions, C Series amplifiers offer advanced features 
to protect both internal circuits and any connected 
loads. These features even protect the mains fuse 
that, in extreme cases, could be overloaded.

Following are short descriptions of standard built-in 
C Series protection features:

 CPL

,  Current  Peak  Limiter  ensures  that  the  

amplifier’s  output  does  not  exceed  the  safe 
current  handling  parameters  of  amplifier  
components.

 Temperature  protection

  ensures  that  the  

amplifier  will  not  be  damaged  by  exceeding 
thermal limits. 

 PAL

, Power Average Limiter limits the maximum 

average power consumption according to the 
power supply and mains-breaker capabilities.

 Vhf

, Very High Frequency protection circuits 

mute  the  output  of  the  amplifier  when  non-
dynamic continuous signals above 10 kHz are 
detected.

 dC protection

 ensures destructive DC signals 

will not appear at the amplifier outputs. If such 
conditions occur an internal fuse opens and fault 
indication is displayed.

 Low  impedance

  (short  circuit)  protection  

provides a fault warning indication and shuts 
down the output stage when, for example, an 
input signal is present and a malfunctioning cable 
or driver is short circuiting the output.

 high impedance

 warning reports an alert when 

at the same time output signal is high, simultane-
ously, and no current draw is measured. This 
situation  might  occur  when  no  speakers  are 
connected, or when a driver is blown.

 Low inrush current

 ensures that the mains 

breaker  will  not  trip  when  several  power  
amplifiers are turned on simultaneously.

4..5  NomadLink / Ethernet control and 

monitoring network

The  NomadLink  network  allows  easy  setup  and  
control  of  C  Series  power  amplifiers  and  other 
devices.  The  patented  network  topology  allows 
automatic  detection  and  addressing  of  multiple 
amplifiers, and is controlled from a PC via a bridge 
(NLB 60E) using standard TCP/IP communication. 
Phantom  powering  through  the  network  cables 
allows the software to detect devices that are not 
currently turned on or connected to the mains. This 
ensures very high reliability and redundancy levels 
while allowing connected amplifiers to remain on 
standby with no power consumption.

Cable  connections  can  be  daisy-chained  for 
easier  system  setup.  This  also  reduces  total  
component costs, simplifies installation, and makes 
daily operation more convenient. There is no need to 
create a star topology using many switches as with, 
for example, an Ethernet system. Individual amplifier 
addresses do not need to be manually entered. You 
will automatically know where an individual amplifier 
resides in the network.

A daisy chain network-loop, in combination with 
the  automatic  addressing  of  devices,  enables 
Lab.gruppen’s  proprietary  DeviceControl  editor  
software to automatically create a precise picture of all  
connected devices and their relative position in the 
chain. This is the key to creating a quick overview 
of the system layout, allowing simple operation of a 
large group of amplifiers. Installation time is kept to 
a minimum, and fast access is provided to monitor 
performance and solve problems during operation.

Via NomadLink, you can monitor all metering data 
as well as all faults and warning indications simulta-
neously. NomadLink also allows you to remotely 
control power on and power off, as well as engage 
Mute and Solo functions on individual channels.

WELCOME  4

Summary of Contents for C 68:4

Page 1: ...Rev 2 01 Operation manual C Series Installation Dedicated Amplifiers C 68 4 C 48 4 C 28 4 C 16 4 Part no UM CS...

Page 2: ...and performance optimization 7 4 2 5 NomadLink Ethernet control and monitoring network 7 5 installation 8 5 1 Unpacking 8 5 2 Mounting 8 5 3 Cooling 8 5 4 Operating voltage 8 5 5 Grounding 9 6 quick g...

Page 3: ...ng open load 19 7 5 6 Lo impedance protection short circuit 19 7 5 7 Temperature protection 20 7 5 8 Power Average Limiter PAL 20 7 5 9 Soft Start 20 7 6 Front panel monitoring and adjustments 21 7 6...

Page 4: ...r replacement of the obsolete outlet Connect only to AC power outlets rated 100 120 V or 200 240 V 50 60 Hz Do not use this amplifier if the power cord is broken or frayed Protect the power cord from...

Page 5: ...pment on and off the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the antenna Increase the separation between the equipment and r...

Page 6: ...impedance or constant voltage 70 V 100 V mode NomadLink an easy to use network for monitoring and control is implemented as a standard feature on all C Series amplifiers Although C Series features and...

Page 7: ...d a malfunctioning cable or driver is short circuiting the output High impedance warning reports an alert when at the same time output signal is high simultane ously and no current draw is measured Th...

Page 8: ...sufficient space to allow the exhaust to escape If the amplifier is rack mounted do not use covers or doors on the front or rear of the rack Should a heat sink overheat the temperature sensing circuit...

Page 9: ...h power is controlled and limited during soft start enabling multiple amplifiers to be powered up simultaneously 5 5 Grounding There is no ground lift switch or terminal on the C Series amplifiers The...

Page 10: ...will not switch on until a Power On command is received from the network When the remote switch is off it is not possible to switch amplifier power on or off using NomadLink network control 6 1 2 Fron...

Page 11: ...t fan feature lowers fan speed when no signal is present Bridged A B and C D Switches the channel pairs into bridged mode operation automatic 6 dB gain compensation VPL Voltage Peak Limiter adjustment...

Page 12: ...erCon XLR type housings on the cables US National Differences cl 16 3 requires that NomadLink network cables must be rated VW 1 The OUT port from the NLB 60E must be connected to the IN port of the fi...

Page 13: ...C Series Operation Manual 13...

Page 14: ...Amplifier Overall amplifier input gain is adjusted using the input stage DIP switches Please note that the gain setting is global affecting all four channels Following the input stage the dedicated l...

Page 15: ...right Complete input sensitivity tables for all VPL and Gain settings for all C Series models can be found at www labgruppen com The headroom available through the input stage to the clip limiter is...

Page 16: ...ained to all speakers in the system As the amplifier outputs produce high voltage do not connect or disconnect speaker cables when the mains power is on Also attach the safety cover on the speaker ter...

Page 17: ...2 Amplifier sensitivity Sensitivity is defined as how many Volts rms or dBu referred to 0 775 Vrms are required to achieve full maximum output power As the output power varies with the load impedance...

Page 18: ...matically un mute An input signal must be present to allow detection of short circuit or low impedance conditions If the CPL LED is steadily illuminated orange while the output is muted and the 4 dB s...

Page 19: ...er Output will be muted long before maximum output power is attained To measure the true peak output power use a burst signal 7 5 4 DC protection DC protection is implemented on each output to prevent...

Page 20: ...ntervals The output will un mute when the channel or power supply returns to a safe operating temperature 7 5 8 Power Average Limiter PAL The Power Average Limiter PAL controls the current drawing rel...

Page 21: ...no speaker is connected For more detailed signal level indications use the DeviceControl editor application 1 2 3 4 5 8 6 2 Level adjust Step Attenuation 1 Min Inf dB 2 Inf dB 3 50 dB 4 40 dB 5 35 dB...

Page 22: ...ce When detected the output will mute for 6 seconds before re measuring the output impedance This will continue until the short circuit is removed CPL remains constant orange in a fault condition only...

Page 23: ...B 60E Should an amplifier fail or be inadvertently disconnected from the mains OPERATION AND PERFORMANCE 7 network integrity is fully maintained and all amplifiers remain visible on the system 7 7 2 C...

Page 24: ...between amplifiers Ethernet Cat5 Ethernet Cat5 Ethernet Cat5 Ethernet Cat5 NLB 60E IN OUT 300m 980ft 300m 980ft 100m 328ft total cable length for links in between amplifiers 300m 980ft Amp 1 IN OUT Am...

Page 25: ...Control editor The DeviceControl editor is Lab gruppen s proprietary software application for monitoring and controlling networked C Series power amplifiers DeviceControl runs on a Windows PC which co...

Page 26: ...feet In a non closed loop daisy chained subnet the maximum cable length is 400 meters 1300 feet In a closed loop subnet the maximum cable length is 700 meters 2300 feet Exceeding these limits may res...

Page 27: ...what you were looking for in this Operation Manual check out the website at www labgruppen com where you can find a multitude of additional documentation for C Series Drawings technical data sheets t...

Page 28: ...dling 1 8 of rated power Pink noise 12 dB crest factor 16 0 8 0 1123 600 523 1784 2484 626 21 2 10 6 1378 600 778 2655 669 570 Max power 3 Pink noise 6dB crest factor 35 2 17 6 2296 1200 1096 3740 942...

Page 29: ...068 9 4 4 7 10 4 5 2 529 663 269 564 567 Max power 3 Pink noise 6dB crest factor 24 0 12 0 1790 1589 933 16 A CEE7 20 A 5 20P 467 451 21 4 10 7 1458 933 115VAC 230VAC In Out Dissipated BTU hr kCal hr...

Page 30: ...r 2 ch s 1 3400 W 2400 W 1200 W 600 W 4 ohms bridged per 2 ch s 1 2400 W 1200 W 600 W n r 4 Hi Z 140V 200V bridged per 2 ch s 1 3200 W 1800 W 1400 W 800 W Mains connector 230V CE version 16A CEE7 16A...

Page 31: ...lly balanced Output connectors per ch Barrier strip 2 pole screw terminals Output bridge mode A B and or C D inputs A and C are signal source NomadLink network On board 2 x RJ45 EtherCon connectors IN...

Page 32: ...any loss due to cancellation of any events or rent of replace ment equipment or costs due to a third party s or customer s loss of profit or any other indirect cost or losses however incurred Lab grup...

Page 33: ...L a b g r u p p e n AB S w e d e n 4 6 3 0 0 5 6 2 8 0 0 T C El e ct r o n i c I n c U S a 8 1 8 6 6 5 4 9 0 0 m a i l i n f o L ABGRUPPEN c o m w w w l a b g r u p p e n c o m...

Reviews: