8  

C Series Operation Manual 

5.1  unpacking

Carefully open the shipping carton and check for any 
noticeable damage. Every Lab.gruppen amplifier is 
tested and inspected before leaving the factory and 
should arrive in perfect condition. If any damage 
is discovered, please notify the shipping company 
immediately. Only the consignee may institute a 
claim with the carrier for damage incurred during 
shipping. Save the carton and packing materials for 
the carrier’s inspection. Should you ever need to 
ship the amplifier, always use the original packaging 
materials.

5.  Mounting

The amplifier is two rack units high (2U) and will fit 
into a standard EIA 19” rack. 
The depth is 343 mm (13.5”). 
The weight is approximately 12 kg (26.4 lbs.) depen-
ding on model type.

Free airflow from front to rear of the amplifier must 
be possible. Therefore, no doors or rack-lids should 
be mounted in front of or behind the amplifiers.

Amplifiers may be stacked directly on top of each 
other. There is no need for spacing in between units, 
though this might enable more convenient installation 
of cabling on the rear-panel. 

It is recommended that rear supports be mounted 
for maximum long-term stability.

5.3  Cooling 

The  amplifier  uses  a  forced-air  cooling  system 
with air flow from front to rear, maintaining a low  
operating temperature within defined limits. Front-to-
rear airflow is preferred as cooler air is present at the 
front in nearly all installed applications. (This allows 
higher continuous power levels without encountering 
thermal problems.) Never attempt to reverse the 
airflow. The amplifier modules require a pressure 
chamber between the fans and heatsink, and this 
effect functions only in one direction.

Make sure that there is an adequate air supply in front 
of the amplifier, and that the rear of the amplifier has 
sufficient space to allow the exhaust to escape. If 
the amplifier is rack-mounted, do not use covers or 
doors on the front or rear of the rack. 

Should  a  heat  sink  overheat,  the  temperature 
sensing circuits will mute the overheating channel. 
If  the  power  supply  overheats,  another  sensing 
circuit will mute all output channels until the power  
supply cools to safe operating temperature. An early  
warning before shut down will be indicated on the 
front panel LEDs, and a warning will be sent through 
the NomadLink network.

Always make sure that the dust-filters behind the 
detachable front panel are clean to ensure maximum 
possible airflow. 

If the amplifier malfunctions due to dirty 
dust filters, any required repairs are not 
covered by the warranty.

To calculate the maximum heat emission value, when 
installing the amplifiers in rooms with an air-conditio-
ning system, please refer to the BTU specifications 
provided in the Appendix section.

5.4  Operating voltage 

The label placed to the right of the mains 

cable on the rear of the amplifier indicates the 

AC mains voltage for which the amplifier is wired 
and approved: 115 V or 230 V. Connect the power 
cable only to the AC source type referred to on the 
label. The warranty will not cover damage caused by 
connecting to an incorrect type of AC mains.

Lab.gruppen switch mode amplifiers use primary 
switching.  Because  the  mains  power  is  rectified 
directly in front of the transformer, the amplifier is 
insensitive to mains frequency. It may be connected 
to 50 or 60Hz sources, and actually will operate on 
line frequencies from DC to 400 Hz. 

If  the  power  plug  mounted  at  the  factory  is  not  
appropriate for your country, it can be removed and 
the proper connector wired in its place as follows. 

BLACK or BROWN 

 

 

LIVE

WHITE or BLUE 

 

 

NEUTRAL

GREEN or GREEN/YELLOW      EARTH(GROUND)

 

 

Warning:  If  you  are  not  100%  confident  of  your  
competence  to  replace  the  mains  plug,  engage 
qualified personnel to do the job.

Once  a  suitable  AC  supply  is  connected,  the  

5  INsTALLATION

Summary of Contents for C 68:4

Page 1: ...Rev 2 01 Operation manual C Series Installation Dedicated Amplifiers C 68 4 C 48 4 C 28 4 C 16 4 Part no UM CS...

Page 2: ...and performance optimization 7 4 2 5 NomadLink Ethernet control and monitoring network 7 5 installation 8 5 1 Unpacking 8 5 2 Mounting 8 5 3 Cooling 8 5 4 Operating voltage 8 5 5 Grounding 9 6 quick g...

Page 3: ...ng open load 19 7 5 6 Lo impedance protection short circuit 19 7 5 7 Temperature protection 20 7 5 8 Power Average Limiter PAL 20 7 5 9 Soft Start 20 7 6 Front panel monitoring and adjustments 21 7 6...

Page 4: ...r replacement of the obsolete outlet Connect only to AC power outlets rated 100 120 V or 200 240 V 50 60 Hz Do not use this amplifier if the power cord is broken or frayed Protect the power cord from...

Page 5: ...pment on and off the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the antenna Increase the separation between the equipment and r...

Page 6: ...impedance or constant voltage 70 V 100 V mode NomadLink an easy to use network for monitoring and control is implemented as a standard feature on all C Series amplifiers Although C Series features and...

Page 7: ...d a malfunctioning cable or driver is short circuiting the output High impedance warning reports an alert when at the same time output signal is high simultane ously and no current draw is measured Th...

Page 8: ...sufficient space to allow the exhaust to escape If the amplifier is rack mounted do not use covers or doors on the front or rear of the rack Should a heat sink overheat the temperature sensing circuit...

Page 9: ...h power is controlled and limited during soft start enabling multiple amplifiers to be powered up simultaneously 5 5 Grounding There is no ground lift switch or terminal on the C Series amplifiers The...

Page 10: ...will not switch on until a Power On command is received from the network When the remote switch is off it is not possible to switch amplifier power on or off using NomadLink network control 6 1 2 Fron...

Page 11: ...t fan feature lowers fan speed when no signal is present Bridged A B and C D Switches the channel pairs into bridged mode operation automatic 6 dB gain compensation VPL Voltage Peak Limiter adjustment...

Page 12: ...erCon XLR type housings on the cables US National Differences cl 16 3 requires that NomadLink network cables must be rated VW 1 The OUT port from the NLB 60E must be connected to the IN port of the fi...

Page 13: ...C Series Operation Manual 13...

Page 14: ...Amplifier Overall amplifier input gain is adjusted using the input stage DIP switches Please note that the gain setting is global affecting all four channels Following the input stage the dedicated l...

Page 15: ...right Complete input sensitivity tables for all VPL and Gain settings for all C Series models can be found at www labgruppen com The headroom available through the input stage to the clip limiter is...

Page 16: ...ained to all speakers in the system As the amplifier outputs produce high voltage do not connect or disconnect speaker cables when the mains power is on Also attach the safety cover on the speaker ter...

Page 17: ...2 Amplifier sensitivity Sensitivity is defined as how many Volts rms or dBu referred to 0 775 Vrms are required to achieve full maximum output power As the output power varies with the load impedance...

Page 18: ...matically un mute An input signal must be present to allow detection of short circuit or low impedance conditions If the CPL LED is steadily illuminated orange while the output is muted and the 4 dB s...

Page 19: ...er Output will be muted long before maximum output power is attained To measure the true peak output power use a burst signal 7 5 4 DC protection DC protection is implemented on each output to prevent...

Page 20: ...ntervals The output will un mute when the channel or power supply returns to a safe operating temperature 7 5 8 Power Average Limiter PAL The Power Average Limiter PAL controls the current drawing rel...

Page 21: ...no speaker is connected For more detailed signal level indications use the DeviceControl editor application 1 2 3 4 5 8 6 2 Level adjust Step Attenuation 1 Min Inf dB 2 Inf dB 3 50 dB 4 40 dB 5 35 dB...

Page 22: ...ce When detected the output will mute for 6 seconds before re measuring the output impedance This will continue until the short circuit is removed CPL remains constant orange in a fault condition only...

Page 23: ...B 60E Should an amplifier fail or be inadvertently disconnected from the mains OPERATION AND PERFORMANCE 7 network integrity is fully maintained and all amplifiers remain visible on the system 7 7 2 C...

Page 24: ...between amplifiers Ethernet Cat5 Ethernet Cat5 Ethernet Cat5 Ethernet Cat5 NLB 60E IN OUT 300m 980ft 300m 980ft 100m 328ft total cable length for links in between amplifiers 300m 980ft Amp 1 IN OUT Am...

Page 25: ...Control editor The DeviceControl editor is Lab gruppen s proprietary software application for monitoring and controlling networked C Series power amplifiers DeviceControl runs on a Windows PC which co...

Page 26: ...feet In a non closed loop daisy chained subnet the maximum cable length is 400 meters 1300 feet In a closed loop subnet the maximum cable length is 700 meters 2300 feet Exceeding these limits may res...

Page 27: ...what you were looking for in this Operation Manual check out the website at www labgruppen com where you can find a multitude of additional documentation for C Series Drawings technical data sheets t...

Page 28: ...dling 1 8 of rated power Pink noise 12 dB crest factor 16 0 8 0 1123 600 523 1784 2484 626 21 2 10 6 1378 600 778 2655 669 570 Max power 3 Pink noise 6dB crest factor 35 2 17 6 2296 1200 1096 3740 942...

Page 29: ...068 9 4 4 7 10 4 5 2 529 663 269 564 567 Max power 3 Pink noise 6dB crest factor 24 0 12 0 1790 1589 933 16 A CEE7 20 A 5 20P 467 451 21 4 10 7 1458 933 115VAC 230VAC In Out Dissipated BTU hr kCal hr...

Page 30: ...r 2 ch s 1 3400 W 2400 W 1200 W 600 W 4 ohms bridged per 2 ch s 1 2400 W 1200 W 600 W n r 4 Hi Z 140V 200V bridged per 2 ch s 1 3200 W 1800 W 1400 W 800 W Mains connector 230V CE version 16A CEE7 16A...

Page 31: ...lly balanced Output connectors per ch Barrier strip 2 pole screw terminals Output bridge mode A B and or C D inputs A and C are signal source NomadLink network On board 2 x RJ45 EtherCon connectors IN...

Page 32: ...any loss due to cancellation of any events or rent of replace ment equipment or costs due to a third party s or customer s loss of profit or any other indirect cost or losses however incurred Lab grup...

Page 33: ...L a b g r u p p e n AB S w e d e n 4 6 3 0 0 5 6 2 8 0 0 T C El e ct r o n i c I n c U S a 8 1 8 6 6 5 4 9 0 0 m a i l i n f o L ABGRUPPEN c o m w w w l a b g r u p p e n c o m...

Reviews: