background image

14

CA SERIES

Quick Start Guide

15

Specifications

CA24 02

CA2401

CA1202

CA1201

CA602

CA601

Maximum Outpu t Power

4 or 8 Ω per channel

240 W

120 W

60 W

Number of Ouput Channels

Number

2

1

2

1

2

1

Minimun Load Impedance

4 Ω mode

4 Ω

8 Ω mode

8 Ω

70 V output mode

20 Ω

41 Ω

82 Ω

100 V output mode

41 Ω

82 Ω

166 Ω

Controls

Front

Power standby button, gain control, tone controls - bass and treble

Rear

Load config - (4 Ω / 8 Ω / 70 V / 100 V), switchable 80 Hz high-pass filter

Tone Controls

Bass

±10 dB @ 100 Hz

Treble

±10 dB @ 10 kHz

Indicators

Power

On (blue), force standby (red), sleep (yellow)

Master

Signal (green LED)

>12.3 mV (-36 dBu)

Limit (red LED)

Input clip, output limit

Fault (red LED)

Overheat, DC fault, over current, etc

System

Inputs

2 x 3-pin  

5.08 mm Euroblock 

connector 

2 x RCA stereo 

summed

1 x 3-pin  

5.08 mm Euroblock 

connector 

1 x RCA stereo 

summed

2 x 3-pin  

5.08 mm Euroblock 

connector 

2 x RCA stereo 

summed

1 x 3-pin  

5.08 mm Euroblock 

connector 

1 x RCA stereo 

summed

2 x 3-pin  

5.08 mm Euroblock 

connector 

2 x RCA stereo 

summed

1 x 3-pin  

5.08 mm Euroblock 

connector 

1 x RCA stereo 

summed

Input impedance

10 kΩ unbalanced and RCA, 20 kΩ balanced

Input sensitivty

Balanced: 1.23 V (+4 dBu) 

RCA: 0.62 V (-2 dBu) each for mono sum RCA

Maximum input 

level

9.75 V (+22 dBu)

Outputs

1 x 4-pin  

5.08 mm Euroblock 

connector

1 x 2-pin  

5.08 mm Euroblock 

connector

1 x 4-pin  

5.08 mm Euroblock 

connector

1 x 2-pin  

5.08 mm Euroblock 

connector

1 x 4-pin  

5.08 mm Euroblock 

connector

1 x 2-pin  

5.08 mm Euroblock 

connector

Output circuit type

Class D

Remote connector

2 x RJ45 connector

1 x RJ45 connector

2 x RJ45 connector

1 x RJ45 connector

2 x RJ45 connector

1 x RJ45 connector

CA24 02

CA2401

CA1202

CA1201

CA602

CA601

Performance

Distortion, 

1/8 rated power

<0.05%

Frequency 

response

20 Hz to 20 kHz, +0.5 / -1 dB

Crosstalk  

(2 channel models)

>85 dB

Signal-to-noise 

>97 dBA

High-pass filter

80 Hz HPF

Circuit Protection

Cooling

Convection-cooled, fanless

Amplifier 

protection

Thermal protection, over current protection, DC protection, high frequency protection

Load protection

Controlled start and shutdown behaviour, DC-fault protection

Power Supply, Voltage (Fuse)

Main voltage

100-240 V~, 50/60 Hz with  

active power factor correction

100-240 V~, 50/60 Hz

Fuse

T 6.3 A L 250 V

T 3.15 A L 250 V

Power 

consumption

1/8th rated power 

@ 4 Ω

120 W

70 W

50 W

60 W

40 W

Mains connector

Standard IEC connector

Dimensions / Weight

Dimensions 

(H x W x D)

44 x 218 x 299 mm (1.7 x 8.6 x 11.8")

Weight

2.6 kg (5.8 lbs)

2.4 kg (5.3 lbs)

2.6 kg (5.8 lbs)

2.3 kg (5.1 lbs)

2.4 kg (5.3 lbs)

2.2 kg (4.9 lbs)

Finish

Brushed black anodized aluminum chassis with black painted steel bottom

Approvals

CE, cTUVus, PSE, CCC, RoHS, FCC part 15 Class B and Energy Star 3.0

Summary of Contents for CA Series

Page 1: ...Quick Start Guide CA Series CA2402 CA2401 CA1202 CA1201 CA602 CA601 Commercial Amplifier with Energy Star Certification...

Page 2: ...tormsor whenunusedforlongperiodsoftime 14 Referallservicingtoqualifiedservicepersonnel Servicingisrequiredwhentheapparatushasbeen damagedinanyway suchaspowersupplycordorplug isdamaged liquidhasbeenspi...

Page 3: ...8 CA SERIES CA Series Hook up Hook Up Loudspeakers...

Page 4: ...Quick Start Guide 9 Remote CM Series Mixer...

Page 5: ...10 CA SERIES CA Series Controls 1 3 2 4 5 6 7 8 9...

Page 6: ...d load type See Getting Started section for details 6 Output Connect your speaker s 7 Remote Allows the connection of an external volume control module per channel CRC V available as a separate access...

Page 7: ...single CA unit can be installed in a 19 rack using the long angle bracket or in a half 19 rack using the short angled brackets Attach the angled brackets by unscrewing the chassis side front screws a...

Page 8: ...or a single 8 speaker The 4 setting should be used for 4 x 16 2 x 8 or a single 4 speaker Use 70 or 100V setting for Constant Voltage high impedance speaker systems Make sure the sum of the power tap...

Page 9: ...nector 2 x RCA stereo summed 1 x 3 pin 5 08 mm Euroblock connector 1 x RCA stereo summed 2 x 3 pin 5 08 mm Euroblock connector 2 x RCA stereo summed 1 x 3 pin 5 08 mm Euroblock connector 1 x RCA stere...

Page 10: ...t and shutdown behaviour DC fault protection Power Supply Voltage Fuse Main voltage 100 240 V 50 60 Hz with active power factor correction 100 240 V 50 60 Hz Fuse T 6 3 A L 250 V T 3 15 A L 250 V Powe...

Page 11: ...ributeursdevotrepaysdanslapage Support de notresiteInternetlabgruppen com Sivotrepaysn est pasdanslaliste essayezder soudrevotreprobl me avecnotre aideenligne quevoustrouverez galement danslasection S...

Page 12: ...this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference b...

Page 13: ......

Reviews: