12
FA Series
Quick Start Guide
13
FA Series Getting started
Welcome to the FA series Quick Start Guide and thank you for purchasing one of
these amplifiers. The following accessories should be included with your product:
• •
Euroblock input connector(s)
• •
Euroblock output connector(s)
• •
Coupling plate (x2) with necessary screws
• •
Long angle bracket
• •
Front angle bracket (x2)
• •
Rear flat bracket
• •
Rear angle bracket with shoulder screw
• •
Power cable with mains plug corresponding to the specified country version
• •
Quick Start Guide (this document)
Rack Mounting
The FA series amplifiers come with rubber feet that enable the amps to be
placed on a clear surface without an additional installation. However, optional
rack mounting hardware is also supplied, allowing several models to be
housed and protected inside an enclosure. Follow these steps to attach the
mounting hardware.
A pair of FA units can be mounted side-by-side to occupy a single rack space.
Attach the coupling plate to the underside of 2 FA units using the
included screws.
Attach the front angle brackets to either side of a pair of FA units that have been
coupled. Alternatively, a single FA unit can be installed in a 19" rack using the
long angle bracket, or in a half 19" rack using the short angled brackets.
Attach the angled brackets, by unscrewing the chassis side front screws and
attach again together with the brackets.
If your rack has rear rails, attach the rear flat brackets by reusing the screws from
the chassis.
Mount the FA units into the rack by attaching 4 rack screws through the front
angle brackets and rack rails.
Hold one of the rear angle brackets up to the rear rack rails so that it lines up next
to the rear flat bracket. Do not attach it to the rear rails yet.
Insert the included shoulder screw through the slot in the rear flat bracket and
into one of the threaded holes in the rear angle bracket. The screw should allow
the rear angle bracket to slide forward and back within the flat bracket’s slot.
Repeat the process for the other rear angle bracket.
Mount the rear angle brackets to the rear rack rails using 4 standard rack screws.
Tighten the shoulder screw if necessary.
The standard rack screw is M4 x 8mm.
The FA series amplifiers are convection cooled and primarily use the top surface
to dissipate heat. For demanding applications, it is recommended to have
sufficient space (1 RU) above the amplifier to reduce the risk of limiting due
to overheating.
Table/Wall Mounting
Connect a pair of coupling plates to either side of a FA series amplifier, then
mount screws through the remaining holes in the plates to secure the unit to a
wall or table.
Connections
For balanced input connections, use a 3-pole cable (hot, cold, ground) wired to a
Euroblock connector.
For output signals, connect a 4-pole Euroblock connector to the main output
connector. Do NOT connect any terminal to ground. Do NOT connect the cold (-)
terminals together for common returns. Make sure to set the Config switches in
the correct position to match your intended use. Speaker wire of 14-18 AWG
(0.8 to 2.5 mm) is recommended for connections up to 50 feet.
Config
The first 2 Config dipswitches allow the output to be configured for 100 V, 70 V,
8 Ω, or 4 Ω operation. Always use the correct configuration for the speakers
being driven! The mode of operation configures both the maximum voltage of
the output and the gain through the device.
The 8 Ω setting should be used for a pair of 16 Ω speakers or a single 8 Ω speaker.
The 4 Ω setting should be used for 4 x 16 Ω, 2 x 8 Ω, or a single 4 Ω speaker.
Use 70 or 100 V setting for Constant Voltage high impedance speaker systems.
Make sure the sum of the power tapping on the speakers plus margin does not
exceed the amplifier's maximum power rating.
The 3rd dipswitch engages a high-pass filter at 80 Hz, which should be used on
all Constant Voltage systems to avoid saturation on the transformer-enabled
speakers, but can also be used to help maintain clear sound from small speakers
or bass-heavy audio.
Remote
RJ45 receptacle to connect an optional remote volume control per channel.
Use a standard cable to connect the CRC-V accessory. Or connect a custom
potentiometer with the pinout information. Cable length above 305 m (1000 ft)
is not recommended.
Signal Wake-up
If the amps are powered on, but do not receive any input signal (below signal
present level) for 20 minutes, the system will enter standby mode to save
power consumption. As soon as a signal is detected at any input, the unit will exit
standby mode and resume normal function.
3-Pin Euroblock Connector - Input
1
2
3
1. hot (+)
2. cold (-)
3. ground/shield
1
2
3
4
1. Out A - hot (+)
2. Out A - cold (-)
3. Out B - hot (+)
4. Out B - cold (-)
RJ-45 Pin
Color
(T568B)
Remote
(1 channel
products )
Remote
A+B
Remote B
1
White/
Orange
VCC 10V
VCC 10V
VCC 10V
2
Orange
Volume
Control
Volume
Control
Channel A
Volume
Control
Channel B
3
White/Green
N/A
Volume
Control
Channel B
N/A
8
Brown
Ground
Ground
Ground
GND GPI1 GPI2 VCC GPO
Shield
2 8
1