Max output power 

1)

EIA

EIA

FTC

EIA at 1 kHz and 1% THD

20–20 kHz at 0.1% THD

MLS-switch

–3 dB

0 dB Full

0 dB Full

16 

four channels

95 W

200 W

180 W

four channels

200 W

370 W

360 W

four channels

380 W

590

2)

, 700

3) 

W

530 W

four channels

500

2)

, 650

3) 

W

N/A

N/A

16 

bridged stereo

380 W

740 W

720 W

bridged stereo

760 W

1200

2)

, 1400

3) 

W

1000 W

bridged stereo

1000

2)

, 1280

3) 

W

N/A

N/A

Max output voltage

8 ohms load, MLS @ 0 dB

40 Vrms

54 Vrms

Peak voltage, no load

60 V

81 V

fP 2400Q

Distortion etc.

THD 20 Hz–20 kHz and 1 W to full power

0.07 %

THD @ 1 kHZ and –1 dB under clip

0.02 %

DIM 30 at –3 dB under clip

0.008 %

Hum and Noise

<–107 dB

Channel separation 

@10 kHz

70 dB

Output impedance

30 m

Slew Rate

60 V/

s

Inputs

Gain

32 dB

Impedance 20 

kohm

Common mode rejection 

50 dB

Front Panel

Gain controls

(4) channel A, B, C, D

31 positions 
detent

Clip Indicator

(4) red LEDs

Output headroom 
indicators

(4 

2) green LEDs

Fast peak

–slow release
Protect indicator

(4) yellow LEDs

80°C at heatsink or 
>12 kHz at full power
or shorted output

On Indicator

(4) green LEDs

DC rail voltage for 
channel A, B, C and D

Rear Panel

Input connectors

(4) Neutrik Combo XLR type, 3 pin 
and 1/4˝ jack

Output connectors (4) Neutrik 4-pole Speakon® connectors

Switches:
Clip limiter A and B 

On–Off (switchable)

MLS switch

0, –3 dB

Link-switches

A+B / B+C / C+D

Power

230 V version

115 V version

Operation voltage

130 V–265 V AC 65 V–135 V AC

Minimum start voltage

175 V

85 V AC

Full output power 
at 4 ohms

200 V–265 V AC 100 V–130 V AC

Peak inrush current 
(Soft start limited)

5 A

5 A

Current Draw @ 4ohms&230V

Quiescent power (no load) 1.4 Arms

2.8 Arms

1/8 of full power (–9 dB)

6 Arms

12 Arms

1/3 of full power (–5 dB)

9 Arms 

18 Arms

At full power (0 dB)
@1 kHz 1% THD

16 Arms 

32 Arms 

Net Dimensions 

mm

483 (19˝) W 

88 H 

316D

inch

19˝ W 

3.5˝ H 

12.4˝ D

Shipping Dimensions 

mm

560 W 

180 H 

500 D

inch

22˝ W 

7.1˝ H 

19.7˝D

Weight

Net

8.6 kg (19 lbs)

Shipping

10.2 kg (22.5 lbs)

Approvals

CE:
Emission

EN 55 103-1, E3

Immunity  EN 55 103-2, E3, with S/N below 1% at normal operation level4)
Safety

EN 60065, class I

ETL listed: Conforms to ANSI/UL STD 6500 and Certified to CAN/CSA E60065-00
FCC:

Complies with Class B digital device, Part 15 of the FCC Rules.

NOTES:
1) Specifications measured with 230 V AC
2) Component tolerance dependent
3) Continuous power, one channel driven or peak power both channels driven

(Thermal protection may occur at high continuous power)

4) Normal operation level 1/8 of full power or –9 dB below clip level.

Lab.gruppen reserve the right to alter functions or the specification without prior
notice.