background image

NM=j^fkqbk^k`b=

Under normal use the amplifier should provide years of trouble-free service. The only user maintenance 
required by the user is to vacuum the front grill periodically.  
In some extreme cases it may be necessary for authorized service personnel to clean the inside of the 
amplifier. These conditions usually occur after prolonged use, e.g. in environments using "cracked- oil" 
smoke machines. 
If you are using your amplifier for heavy duty use i.e. concert touring or industrial music it is 
recommended that you have your amplifier serviced every 3 years, purely as a preventative measure. 

NMKN=qêçìÄäÉëÜççíáåÖ=

These are typical things to check if you think your amplifier is faulty: 

Fault: No output. 

If the output bar-graph is illuminating there is nothing wrong with the amplifier; the likely cause is an 
unsecured Speakon speaker connector. 
Check also that the VHF protection is not activated. If it is, remove possible high frequency oscillations 
from the relevant input. 

Fault: The amplifier goes into thermal protection when driven at low level. 

Check that nothing causes a short circuit at the amplifier's output, e.g. any component in the 
loudspeaker (this can occur when the speaker coil gets warm). 

Fault: The amplifier goes into protection with power indicators off. 

Check that the AC line voltage is within the amplifier’s operating range, 130-265V@ 230V, (65-135V 
@ 115V). Over/under-voltage protection may have occurred. If the amplifier is connected by mistake to 
a 3 phase supply, an internal non-resetable fuse or resistor may have blown. Then return the amplifier to 
your supplier for service. 

Fault: The amplifier does not respond even after checking above items. 

In the unlikely event of on a non-user rectifiable fault, return the amplifier to your supplier or an 
approved service centre.  

Lab.gruppen cannot be held responsible for damage or injury as a result of the top or bottom 
cover being removed. 
 

i~ÄKÖêìééÉå== =

=

=

=

======================

========================

NT

 

rëÉê=j~åì~ä===Ñm=OQMM=n=====sÉêëáçå=MKU========OMMPJNMJMT=

Summary of Contents for fP Series FP 2400Q

Page 1: ...m OQMMn rpbo j kr i...

Page 2: ...ing MLS switch 9 5 4 1 A practical way to find your MLSTM settings 9 5 4 2 MLS technology the background 10 5 4 3 The problem 10 5 4 4 The solution 10 6 INSTALLATION 10 6 1 Mounting 10 6 2 Cooling 10...

Page 3: ...isk of fire or electric shock do not expose this apparatus to rain or moisture PKP rqflk To reduce the risk of fire or electric shock do not remove screws No user serviceable parts inside Refer servic...

Page 4: ...ery powerful and can be potentially dangerous to both loudspeakers and humans alike Many loudspeakers can be easily damaged or destroyed by overpowering especially with the high power available from a...

Page 5: ...ys use the original packing QKO c m Figure 1 front panel 1 Carry protection handle Both handles can be used to carry the amplifier they also act as protection for the front panel In permanent installa...

Page 6: ...ns mains power on or off See page 11 and 14 QKP o m Figure 2 Rear Panel 1 Output Speaker connector The Speakon connector from Neutrik may be unfamiliar to some users A full description can be found in...

Page 7: ...level in different load impedances Sensitivity in Vrms fP 2400Q MLS SWITCH SETTING LOAD CONFIGURATION 3 dB 0 dB 16 ohms Quad 4 channel 0 98 1 42 8 ohms Quad 4 channel 1 00 1 37 4 ohms Quad 4 channel 0...

Page 8: ...are connected in normal polarity mode By having channel A and B and C and D operating in opposite polarity the energy storage in the power supply is more efficient This is significant for signals bel...

Page 9: ...results in twice the voltage swing four times the peak power and just less than three times the full power of a single channel One way to understand the load and power from the amplifier s perspective...

Page 10: ...ion for your application There is no risk to damage the amplifier since it is very well protected even down to 0 3 ohms If uncertain or where time does not allow just stick to the default positions Th...

Page 11: ...adjusted for a much higher current so it cannot interfere with the requirements by the loudspeaker impedance curve S fkpq ii qflk SKN j The amplifier is two rack units high 2U and will fit into a sta...

Page 12: ...a short circuit is introduced between the two thereby enabling electrical protection If a unit in the system is faulty its mains fuse will blow due to this automatic ground system If however you wish...

Page 13: ...175 MLS at 3dB note 1 Average power with music as program source The amplifier driven to clip level note 2 Normal music power with 9dB headroom IEC standard power rating MAINS INPUT POWER MAX OUTPUT...

Page 14: ...ms to avoid high frequency loss in lo cables TRS p g If you leave a pin di A better method for using unbalanced sources is shown in Figure 8 This is similar to the connection for balanced lines but pi...

Page 15: ...that the AC mains voltage is correct and the same as the one printed on the rear panel of the amplifier See pages 10 about operating voltage and power consumption Make sure that the switches on the r...

Page 16: ...utput and comparing the distortion produced between the input and output of the amplifier If the distortion exceeds 1 THD for any reason voltage or current clipping the limiter reduces the input signa...

Page 17: ...VKNKR If the AC mains voltage is lower or higher than the allowed operational voltage over or under voltage the power supply will automatically shut down Once the mains voltage is above the minimum s...

Page 18: ...ion is not activated If it is remove possible high frequency oscillations from the relevant input Fault The amplifier goes into thermal protection when driven at low level Check that nothing causes a...