R= ob^o=m^kbi=cb^qrobp=
Before turning the amplifier on please read the following sections to make sure that the unit is set up
properly for your specific application.
RKNKN= d~áå=
The gain of the fP 2400 is fixed to 32 dB
RKNKO= pÉåëáíáîáíó=
Sensitivity is defined as how many volts (rms) or dBu (referred to 0.775Vrms) are required to get full
output power. As the output power varies with the load impedance, usually 4 ohms is the reference. But
in the case of an MLS-switch equipped amplifier there are many choices for full output level in different
load impedances.
Sensitivity in Vrms
fP 2400Q
MLS SWITCH SETTING
LOAD
CONFIGURATION
-3 dB
0 dB
16 ohms
Quad (4 channel)
0,98
1,42
8 ohms
Quad (4 channel)
1,00
1,37
4 ohms
Quad (4 channel)
0,98
1,33
2 ohms
Quad (4 channel)
0,91
16 ohms
Stereo (2 channels bridged)
0,98
1,37
8 ohms
Stereo (2 channels bridged)
0,98
1,33
4 ohms
Stereo (2 channels bridged)
0,90
Sensitivity in dBu
fP 2400Q
MLS SWITCH SETTING
LOAD
CONFIGURATION
-3 dB
0 dB
16 ohms
Quad (4 channel)
2,0
5,3
8 ohms
Quad (4 channel)
2,3
4,9
4 ohms
Quad (4 channel)
2,0
4,7
2 ohms
Quad (4 channel)
1,4
16 ohms
Stereo (2 channels bridged)
2,1
4,9
8 ohms
Stereo (2 channels bridged)
2,1
4,7
4 ohms
Stereo (2 channels bridged)
1,3
i~ÄKÖêìééÉå== =
=
=
=
======================
========================
S
rëÉê=j~åì~ä===Ñm=OQMM=n=====sÉêëáçå=MKU========OMMPJNMJMT=