28
FP+ Series Operation Manual
8 APPENDIX
8.4 Current draw and Thermal dissipation specifications
The following tables contain information on measured current consumption as well as calculated heat dissipa-
tion during normal operation(1/8 rated power); and during extreme heavy duty operation (1/4 rated power).
The following tables contain information on measured current consumption as well as calculated heat dissipation during normal operation
(1/8 rated power); and during extreme heavy duty operation (max power).
FP 14000
Level
Load
Rated power
Line Current *2)
Watt *1)
Thermal dissipation
120 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby with remote power off via Nomadlink
®
0
0
0
0
0
Power on, Idling
122
0
122
416
105
Amp (I)
Watt
Pink noise
(1/8th rated
power)
16 Ω / Ch.
1200 x 2
9.1
4.8
628
300
328
1118
282
32 Ω / Bridged
2400 x 1
8 Ω / Ch.
2350 x 2
14.8
7.7
1081
588
493
1683
424
16 Ω / Bridged
4700 x 1
4 Ω / Ch.
4400 x 2
23.9
12.5
1880
1100
780
2661
670
8 Ω / Bridged
8800 x 1
2 Ω / Ch. *4)
7000 x 2
34.0
17.8
2750
1750
1000
3412
860
4 Ω / Bridged *4)
14000 x 1
Pink noise
(max power)
*3)
16 Ω / Ch.
1200 x 2
16.0
8.4
1253
800
453
1546
390
32 Ω / Bridged
2400 x 1
8 Ω / Ch.
2350 x 2
30.0
16.0
2259 / 2409
1500 / 1600
759 / 809
2589 / 2762
652 / 696
16 Ω / Bridged
4700 x 1
4 Ω / Ch.
4400 x 2
30.0
16.0
2320 / 2474
1463 / 1560
857 / 914
2926 / 3121
737 / 786
8 Ω / Bridged
8800 x 1
2 Ω / Ch.
7000 x 2
30.0
16.0
2277 / 2429
1266 / 1350
1012 / 1079
3453 / 3683
870 / 928
4 Ω / Bridged
14000 x 1
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
30 A, Twist lock
*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specifi ed here
is what is known as the “Active Power” of the amplifi er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily
in excess of max. ratings.
*4) Italics used for conditions that, if sustained over long time periods, may trigger the mains breaker. Therefore these measurements should not be used when
calculating cooling requirements as they cannot be sustained by the mains breaker over time.
Table 8.4a: FP 14000 Current Draw and Thermal Dissipation specifications