FP+ Series Operation Manual
29
APPENDIX 8
FP 13000
Level
Load
Rated power
Line Current *2)
Watt *1)
Thermal dissipation
120 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby with remote power off via Nomadlink
®
0
0
0
0
0
Power on, Idling
129
0
129
440
111
Amp (I)
Watt
Pink noise
(1/8th rated
power)
16 Ω / Ch.
1200 x 2
10.2
5.3
678
300
378
1289
325
32 Ω / Bridged
2400 x 1
8 Ω / Ch.
2350 x 2
15.6
8.1
1083
588
495
1690
426
16 Ω / Bridged
4700 x 1
4 Ω / Ch.
4400 x 2
25.4
13.2
1856
1100
756
2578
650
8 Ω / Bridged
8800 x 1
2 Ω / Ch. *4)
6500 x 2
36.2
18.9
2536
1625
911
3109
783
4 Ω / Bridged *4)
13000 x 1
Pink noise
(max power)
*3)
16 Ω / Ch.
1200 x 2
15.3
8.0
1037
800
237
807
203
32 Ω / Bridged
2400 x 1
8 Ω / Ch.
2350 x 2
26.0
13.6
1840
1567
273
933
235
16 Ω / Bridged
4700 x 1
4 Ω / Ch.
4400 x 2
30.0
16.0
2199 / 2249
1435 /1487
764 / 763
2609 / 2603
657 / 656
8 Ω / Bridged
8800 x 1
2 Ω / Ch.
6500 x 2
30.0
16.0
2041 / 2093
1227 / 1267
814 / 826
2778 / 2818
700 / 710
4 Ω / Bridged
13000 x 1
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
30 A, Twist lock
*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specifi ed here
is what is known as the “Active Power” of the amplifi er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily
in excess of max. ratings.
*4) Italics used for conditions that, if sustained over long time periods, may trigger the mains breaker. Therefore these measurements should not be used when
calculating cooling requirements as they cannot be sustained by the mains breaker over time.
Table 8.4b: FP 13000 Current Draw and Thermal Dissipation specifications