30
FP+ Series Operation Manual
8 APPENDIX
FP 9000
Level
Load
Rated power
Line Current *2)
Watt *1)
Thermal dissipation
120 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby with remote power off via Nomadlink
®
1
0
1
3
1
Power on, Idling
122
0
122
416
105
Amp (I)
Watt
Pink noise
(1/8th rated
power)
16 Ω / Ch.
800 x 2
6.7
3.5
477
200
277
944
238
32 Ω / Bridged
1600 x 1
8 Ω / Ch.
1600 x 2
11.0
5.7
799
400
399
1362
343
16 Ω / Bridged
3200 x 1
4 Ω / Ch.
3000 x 2
18.5
9.7
1398
750
648
2212
557
8 Ω / Bridged
6000 x 1
2 Ω / Ch.
4500 x 2
26.3
13.7
2053
1125
928
3166
798
4 Ω / Bridged
9000 x 1
Pink noise
(max power)
*3)
16 Ω / Ch.
800 x 2
12.2
6.4
930
533
396
1352
341
32 Ω / Bridged
1600 x 1
8 Ω / Ch.
1600 x 2
22.0
11.5
1707
1067
640
2185
550
16 Ω / Bridged
3200 x 1
4 Ω / Ch.
3000 x 2
30.0
16.0
2278 / 2430
1419 / 1514
859 / 916
2931 / 3126
738 / 788
8 Ω / Bridged
6000 x 1
2 Ω / Ch.
4500 x 2
30.0
16.0
2258 / 2409
1219 / 1300
1039 / 1109
3548 / 3784
894 / 953
4 Ω / Bridged
9000 x 1
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
30 A, Twist lock
*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specifi ed here
is what is known as the “Active Power” of the amplifi er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily
in excess of max. ratings.
Table 8.4c: FP 9000 Current Draw and Thermal Dissipation specifications