FP+ Series Operation Manual
31
APPENDIX 8
FP 7000
Level
Load
Rated power
Line Current *2)
Watt *1)
Thermal dissipation
120 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby with remote power off via Nomadlink
®
0
0
0
0
0
Power on, Idling
92
0
92
316
80
Amp (I)
Watt
Pink noise
(1/8th rated
power)
16 Ω / Ch.
730 x 2
6.5
3.4
411
183
229
781
197
32 Ω / Bridged
1460 x 1
8 Ω / Ch.
1450 x 2
10.4
5.4
692
363
329
1123
283
16 Ω / Bridged
2900 x 1
4 Ω / Ch.
2800 x 2
16.8
8.7
1176
700
476
1625
409
8 Ω / Bridged
5600 x 1
2 Ω / Ch.
3500 x 2
21.1
11.0
1518
875
643
2195
553
4 Ω / Bridged
7000 x 1
Pink noise
(max power)
*3)
16 Ω / Ch.
730 x 2
18.9
9.8
800
487
313
1070
270
32 Ω / Bridged
1460 x 1
8 Ω / Ch.
1450 x 2
30.0
16.0
1425 / 1436
914 / 924
511 / 512
1744 / 1749
439 / 441
16 Ω / Bridged
2900 x 1
4 Ω / Ch.
2800 x 2
30.0
16.0
2134 / 2183
1382 / 1419
753 / 763
2569 / 2605
647 / 656
8 Ω / Bridged
5600 x 1
2 Ω / Ch.
3500 x 2
30.0
16.0
2316 / 2380
1526 / 1586
790 / 794
2696 / 2710
679 / 683
4 Ω / Bridged
7000 x 1
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
30 A, Twist lock
*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specifi ed here
is what is known as the “Active Power” of the amplifi er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily
in excess of max. ratings.
Table 8.4d: FP 7000 Current Draw and Thermal Dissipation specifications