FP+ Series Operation Manual
33
APPENDIX 8
Item no. CDTD_FP10000Q_V5
L A B . G R U P P E N A B
▸
S W E D E N
I N T E R N A T I O N A L C O N T A C T
▸
I N F O @ L A B G R U P P E N . C O M | U S & C A N A D A C O N T A C T
▸
I N F O @ T C G - A M E R I C A S . C O M
W W W . L A B G R U P P E N . C O M
VHF
TEM
NOMAD
LINK
BRIDGE C+D
SIG -20 -15 -10 -4 VPL CPL
SIG -20 -15 -10 -4 VPL CPL
BRIDGE A+B
MUTE
MUTE
SIG -20 -15 -10 -4 VPL CPL
SIG -20 -15 -10 -4 VPL CPL
HI-IMP
HI-IMP
HI-IMP
HI-IMP
CLIP
CLIP
CLIP
CLIP
VHF
TEM
VHF
TEM
VHF
TEM
PWR
PAL
FP10000Q
-10dB
-inf
0
-10dB
-inf
0
-10dB
-inf
0
-10dB
-inf
0
channel
A
B
channel
C
channel
D
channel
FP SERIES
R
POW
POW
The following tables contain information on measured current consumption as well as calculated heat dissipation during normal operation
(1/8 rated power); and during extreme heavy duty operation (max power).
Current Draw and Thermal Dissipation
FP+ series: Dedicated Touring Amplifi ers
FP 10000Q
FP 10000Q
Level
Load
Rated Power
Line Current *2)
Watt *1)
Thermal dissipation
120 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby with remote power off via Nomadlink
®
0
0
0
0
0
Power on, Idling
139
0
139
475
120
Amp (I)
Watt
Pink noise
(1/8th rated
power)
16 Ω / Ch.
660 x 4
10.7
5.6
732
330
402
1371
345
32 Ω / Bridged
1320 x 2
8 Ω / Ch.
1300 x 4
16.9
8.8
1224
650
574
1958
493
16 Ω / Bridged
2600 x 2
4 Ω / Ch.
2100 x 4
25.9
13.5
1914
1050
864
2949
743
8 Ω / Bridged
4200 x 2
2 Ω / Ch. *4)
2500 x 4
32.2
16.8
2414
1250
1164
3973
1001
4 Ω / Bridged *4)
5000 x 2
Pink noise
(max power)
*3)
16 Ω / Ch.
660 x 4
13.6
7.1
1143
880
263
897
226
32 Ω / Bridged
1320 x 2
8 Ω / Ch.
1300 x 4
22.4
11.7
2096
1733
363
1238
312
16 Ω / Bridged
2600 x 2
4 Ω / Ch.
2100 x 4
30.0
16.0
2377 / 2455
1466 / 1542
910 / 914
3107 / 3118
783 716
8 Ω / Bridged
4200 x 2
2 Ω / Ch.
2500 x 4
30.0
16.0
2237 / 2291
1099 / 1145
1139 / 1146
3886 / 3911
979 / 985
4 Ω / Bridged
5000 x 2
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
30 A, Twist lock
*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specifi ed here
is what is known as the “Active Power” of the amplifi er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily
in excess of max. ratings.
*4) Italics used for conditions that, if sustained over long time periods, may trigger the mains breaker. Therefore these measurements should not be used when
calculating cooling requirements as they cannot be sustained by the mains breaker over time.
Table 8.4f: FP 10000Q Current Draw and Thermal Dissipation specifications