34
FP+ Series Operation Manual
FP 6000Q
Level
Load
Rated power
Line Current *2)
Watt *1)
Thermal dissipation
120 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby with remote power off via Nomadlink
®
0
0
0
0
0
Power on, Idling
134
0
134
456
115
Amp (I)
Watt
Pink noise
(1/8th rated
power)
16 Ω / Ch.
320 x 4
6.7
3.5
423
160
263
898
226
32 Ω / Bridged
640 x 2
8 Ω / Ch.
625 x 4
10.5
5.4
700
313
388
1323
333
16 Ω / Bridged
1250 x 2
4 Ω / Ch.
1250 x 4
17.3
9.0
1215
625
590
2015
508
8 Ω / Bridged
2500 x 2
2 Ω / Ch.
1500 x 4
21.9
11.4
1575
750
825
2817
710
4 Ω / Bridged
3000 x 2
Pink noise
(max power)
*3)
16 Ω / Ch.
320 x 4
11.4
5.9
771
427
344
1175
296
32 Ω / Bridged
640 x 2
8 Ω / Ch.
625 x 4
19.2
10.0
1402
833
569
1942
489
16 Ω / Bridged
1250 x 2
4 Ω / Ch.
1250 x 4
30.0
16.0
2249 / 2305
1310 / 1350
939 / 955
3203 / 3261
807 / 822
8 Ω / Bridged
2500 x 2
2 Ω / Ch.
1500 x 4
30.0
16.0
2244 / 2300
1329 / 1384
915 / 916
3122 / 3125
786 / 787
4 Ω / Bridged
3000 x 2
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
30 A, Twist lock
*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specifi ed here
is what is known as the “Active Power” of the amplifi er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily
in excess of max. ratings.
8 APPENDIX
Table 8.4g: FP 6000Q Current Draw and Thermal Dissipation specifications