15. Appendices
26
LUCIA Operation Manual rev 1.2.0
LUCIA 120/1-70
Level
Load
Output power
Mains
Watt *1)
Thermal Dissipation
VAC
IAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby w. remote Power Off.
230
0,032
0,88
0
1
3
1
120
0,027
0,77
0
1
3
1
100
0,028
0,76
0
1
3
1
Power On, Idling
230
0,12
11,9
0
12
41
10
120
0,19
13,0
0
13
44
11
100
0,22
13,1
0
13
45
11
Pink
pseudo
noise (1/8)
70 V
120
x 1
230
0,30
35,6
15
21
70
18
70 V
120
x 1
120
0,47
33,6
15
19
63
16
70 V
120
x 1
100
0,54
34,4
15
19
66
17
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specified
here is what is known as the “Active Power” in the amplifier providing useful, real-world values of power consumption and heat dissipation.
15. Appendices
22
LUCIA Operation Manual rev 1.1.0
15.4. Thermal dissipation
LUCIA 120/2
Level
Load
Output power
Mains
voltage
Line
current
Watt *1)
Thermal Dissipation
VAC
IAC
In
Out
Dissi-
pated
BTU/hr
kCal/hr
Standby w. remote Power Off.
230
0.032
0.88
0
1
3
1
120
0.027
0.77
0
1
3
1
100
0.028
0.76
0
1
3
1
Power on, Idling
230
0.21
11.9
0
12
41
10
120
0.19
13.0
0
13
44
11
100
0.22
13.1
0
13
45
11
Pink Pseudo
Noise (1/8)
16 Ω / Ch.
30
x 2
230
0.22
25.3
7.5
18
61
15
120
0.34
24.3
7.5
17
57
14
100
0.40
24.6
7.5
17
58
15
8 Ω / Ch.
60
x 2
230
0.30
35.6
15
21
70
18
120
0.47
33.6
15
19
63
16
100
0.54
34.4
15
19
66
17
4 Ω / Ch.
60
x 2
230
0.30
36.3
15
21
73
18
120
0.48
34.9
15
20
68
17
100
0.55
35.3
15
20
69
17
2 Ω / Ch.
60
x 2
230
0.32
37.7
15
23
77
20
120
0.50
36.3
15
21
73
18
100
0.57
36.6
15
22
74
19
*1) The ampli er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and speci ed here
is what is known as the “Active Power” in the ampli er providing useful, real-world values of power consumption and heat dissipation.
LUCIA 120/2M
Level
Load
Output power
Mains
voltage
Line
current
Watt *1)
Thermal Dissipation
VAC
IAC
In
Out
Dissi-
pated
BTU/hr
kCal/hr
Standby w. remote Power Off.
230
0.032
0.88
0
1
3
1
120
0.027
0.77
0
1
3
1
100
0.028
0.76
0
1
3
1
Power on, Idling
230
0.14
14.8
0
15
51
13
120
0.21
13.4
0
13
46
12
100
0.25
14.1
0
14
48
12
Pink Pseudo
Noise (1/8)
16 Ω / Ch.
30
x 2
230
0.25
28.2
7.5
21
71
18
120
0.35
24.7
7.5
17
59
15
100
0.41
25.6
7.5
18
62
16
8 Ω / Ch.
60
x 2
230
0.33
38.5
15
23
80
20
120
0.47
34.0
15
19
65
16
100
0.55
35.4
15
20
70
18
4 Ω / Ch.
60
x 2
230
0.33
39.2
15
24
83
21
120
0.48
35.3
15
20
69
17
100
0.56
36.3
15
21
73
18
2 Ω / Ch.
60
x 2
230
0.34
40.6
15
26
87
22
120
0.51
36.7
15
22
74
19
100
0.59
37.6
15
23
77
19
*1) The ampli er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and speci ed here
is what is known as the “Active Power” in the ampli er providing useful, real-world values of power consumption and heat dissipation.
15. Appendices
LUCIA Operation Manual rev 1.2.0
27
LUCIA 240/2
Level
Load
Output power
Mains
voltage
Line
current
Watt *1)
Thermal Dissipation
VAC
IAC
IN
Out
Dissi-
pated
BTU/hr
kCal/hr
Standby w. remote Power Off.
230
0.032
0.88
0
1
3
1
120
0.027
0.77
0
1
3
1
100
0.028
0.76
0
1
3
1
Power on, Idling
230
0.12
11.9
0
12
41
10
120
0.19
13.0
0
13
44
11
100
0.22
13.1
0
13
45
11
Pink Pseudo
Noise (1/8)
16 Ω / Ch.
60
x 2
230
0.29
34.4
15
19
66
17
120
0.47
34.7
15
20
67
17
100
0.58
34.1
15
19
65
16
8 Ω / Ch.
120
x 2
230
0.42
53.7
30
24
81
20
120
0.70
54.2
30
24
82
21
100
0.81
54.6
30
25
86
21
4 Ω / Ch.
120
x 2
230
0.45
55.2
30
25
86
22
120
0.74
56.7
30
27
91
23
100
0.84
56.8
30
27
91
23
2 Ω / Ch.
120
x 2
230
0.47
59.1
30
29
99
25
120
0.76
58.9
30
29
98
25
100
0.91
61.1
30
31
106
27
*1) The ampli er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and speci ed here
is what is known as the “Active Power” in the ampli er providing useful, real-world values of power consumption and heat dissipation.
LUCIA 240/2M
Level
Load
Output power
Mains
voltage
Line
current
Watt *1)
Thermal Dissipation
VAC
IAC
In
Out
Dissi-
pated
BTU/hr
kCal/hr
Standby w. remote Power Off.
230
0.032
0.88
0
1
3
1
120
0.027
0.77
0
1
3
1
100
0.028
0.76
0
1
3
1
Power on, Idling
230
0.14
14.8
0
15
51
13
120
0.21
13.4
0
13
46
12
100
0.25
14.1
0
14
48
12
Pink Pseudo
Noise (1/8)
16 Ω / Ch.
60
x 2
230
0.31
37.3
15
22
76
19
120
0.48
35.1
15
20
69
17
100
0.60
35.1
15
20
69
17
8 Ω / Ch.
120
x 2
230
0.45
56.6
30
27
91
23
120
0.71
54.6
30
25
84
21
100
0.83
55.6
30
26
87
22
4 Ω / Ch.
120
x 2
230
0.47
58.1
30
28
96
24
120
0.75
57.1
30
27
92
23
100
0.86
57.8
30
28
95
24
2 Ω / Ch.
120
x 2
230
0.49
62.0
30
32
109
28
120
0.77
59.3
30
29
100
25
100
0.93
62.1
30
32
110
28
*1) The ampli er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and speci ed here
is what is known as the “Active Power” in the ampli er providing useful, real-world values of power consumption and heat dissipation.