background image

15. Appendices 

LUCIA Operation Manual  rev 1.2.0

29

       

15.6. Technical Specifications 

General

LUCIA 240/2M

LUCIA 120/2M

LUCIA 60/2M

Number of powered channels

2

2

2

Total output all channels driven

240 W

120 W

60 W

Max output voltage per channel 1)

43.8 Vpeak

31 Vpeak

21.9 Vpeak

Max output current per channel

7.8 Arms

5.5 Arms

3.9 Arms

Max Output Power (all channels driven)

2 ohms

120 W

60 W

30 W

4 ohms

120 W

60 W

30 W

8 ohms

120 W

60 W

30 W

16 ohms

60 W

30 W

15 W

Performance

THD 20 Hz - 20 kHz at 1 W into 8 ohms 

<0.3%

<0.3%

<0.3%

THD 1kHz and 1 dB below clipping

<0.2%

<0.2%

<0.2%

Signal to noise ratio into 8 ohms 

>101 dBA

>98 dBA

>95 dBA

Channel separation (Crosstalk) at1 kHz

>60 dB

>60 dB

>60 dB

Frequency response

5 Hz – 22 kHz

5 Hz – 22 kHz

5 Hz – 22 kHz

Input impedance

10 kOhm

10 kOhm

10 kOhm

Input common mode rejection, CMR

40 dB

40 dB

40 dB

Gain, Sensitivity and Limiters

VPL for 16 ohm mode

44 Vpeak

31 Vpeak

21.9 Vpeak

VPL for 8 ohm mode

44 Vpeak

31 Vpeak

21.9 Vpeak

VPL for 4 ohm mode

31 Vpeak

22 Vpeak

15.5 Vpeak

VPL for 2 ohm mode

22 Vpeak

15 Vpeak

11 Vpeak

Sensitivity, balanced output

4 dBu / 1.23 Vrms

4 dBu / 1.23 Vrms

4 dBu / 1.23 Vrms

Sensitivity, RCA input

-2 dBu / 0.62 Vrms

-2 dBu / 0.62 Vrms

-2 dBu / 0.62 Vrms

Input headroom for clip, balanced 2)

12 dBu / 3.09 Vrms

12 dBu / 3.09 Vrms

12 dBu / 3.09 Vrms

Input headroom for clip, RCA 2)

6 dBu / 1.55 Vrms

6 dBu / 1.55 Vrms

6 dBu / 1.55 Vrms

Connectors and buttons

Input connectors (per channel)

3 - pin detachable screw terminals, electronically balanced

Input connectors (ch. 1 & 2)

Unbalanced RCA type

Output connectors (per channel)

2 - pin detachable screw terminals

Line-level output connectors (ch. 3 & 4)

3 - pin detachable screw terminals, electronically balanced

GPI (power control input) 3)

2 channels of voltage sense type. 4 pins in a detachable screw terminal. Default for gain.

GPO (power state output) 3)

Contact closure type, 2 pins in a detachable screw terminal. Default for external  

monitoring of fault/protection/power off

RS232

Can be controlled and monitored by third parties via RS232 using both the GPI pins

USB

For firmware update and configuration for the matrix models

Level adjustment (per channel) 3)

Front panel potentiometer, detented from -inf to 0 dB

Matrix model features

Inputs processing block 4)

4 EQ sections per input

Mix-matrix routing block 4)

4 in - 4 out mix-matrix controllable from GPI

Output processing block 4)

4 EQ sections per output (presets available for many loudspeakers) 

User adjustable output look ahead limiter 

ADLC (Adaptive ISO 226 compensation)

Two line level outputs 5)

Each capable of driving 6 LUCIA units in parallel

Latency from any input to any output

User adjustable from 9.15 to 137 ms

Power

Nominal voltage

100 – 240 VAC

Operating voltage

85 - 265 VAC

Standby consumption

<1 W

Mains connector

IEC inlet

Cooling

One fan, no filter required, front-to-rear air ow, temperature controlled speed. Can stay off if the 

sustained power average stays below 2 x 6 W and the surrounding temperature is below 25 degrees C

Auto mode

The power state is controlled automatically with the audio signal

Dimensions

W: 216 mm (8.5”), H: 44 mm (1.7”), D: 280 mm (11”)

Weight

1.9 kg (4.2 lbs)

Finish

Black aluminium front and black steel chassis

Approvals

CE, CSA, CCC, PSE, FCC, ENERGY STAR

Note 1):

 Into 8 ohms and higher 

Note 2):

 An analog soft limit will be engaged on the input above this level to reduce the clip distortion 

Note 3):

 Can be configured for different functionality via USB 

Note 4):

 DSP settings determined by settings downloaded from the Application Browser software; not configurable on the unit itself 

Note 5):

 Noise levels typically allow daisy chaining of 3 LUCIA amplifiers without issues 

All specifications are subject to change without notice.

Summary of Contents for LUCIA 120/2

Page 1: ...LUCIA Compactinstallationamplifiers Operation Manual Rev 1 2 0 Item no OM LUCIA...

Page 2: ...lly or has been dropped 2 Approvals 3 Warnings 3 1Explanationofwarningsymbols This equipment has been tested and found to comply with the limits for a Class B Digital device pursuant to part 15 of the...

Page 3: ...ns power is on 3 1 3Radiointerference A sample of this product has been tested and complies with the limits for the European Electro Magnetic Compatibility EMC directive It also has been tested and fo...

Page 4: ...240 2M only 6 6 Unpacking and visual checks 7 7 Installation 7 7 1 Wall mounting 7 7 2 Rack shelf mounting 7 7 3 Lab gruppen rack shelf kit 7 8 Cooling and fan operation 8 9 Operating voltage 8 10 Gr...

Page 5: ...2 4 Control block 19 14 6 Saving and storing custom applications 20 14 6 1 Saving applications 20 14 6 2 Storing and sharing applications 20 14 7 Programming a LUCIA device 20 14 8 Online mode 21 21...

Page 6: ...e Windows and Mac software wizard for initial set up and advanced editor for preset configuration LUCIA connection via USB RS232 Remote control and monitoring from third party control solutions GPIO R...

Page 7: ...similar 3 mm Torx machine screws 7 2 Rackshelfmounting of the three holes in the bottom marked A on the drilling guide see inside the shipping box Use a 4 mm diameter machine screw not supplied ensur...

Page 8: ...t 1 m for 1 W then the fan will stay silent for SPL levels up to 95 dB 87 7 8 at 1 m distance from the loudspeaker at 2 5 m from the loudspeaker will maintain levels up to 87 dB with the fan off If th...

Page 9: ...ged when The channel reaches the voltage limit as determined by the automatic Voltage Peak Limiter VPL setting Maximum current output is reached Mains voltage cannot maintain rail voltage Red Channel...

Page 10: ...o avoid low frequency cancellation loss Note Bridge mode connection is not supported 4 GPIO Remote connector Connect external control and status monitoring devices using the six pole 5 USB port Connec...

Page 11: ...g on the loudspeaker transformer Consequently taps should be set to twice the desired power 4 GPIO Remote connector Connect external control and status monitoring devices using the six pole Euroblock...

Page 12: ...control The default functionality for the GPI is independent control of output volume output 1 on GPI1 and output 2 on GPI2 Please note that this control is in series with the control on the front pan...

Page 13: ...wake up Connect an external contact closure to Ground and GPI2 as shown in the diagram follow ing Wake up happens within 0 5 s after contact closure Amplifier status Pins 5 and 6 connect to an intern...

Page 14: ...e that there is no separate desktop documents where write privileges are available The LUCIA Applciation Browser is a simple intuitive software editor for configuring the signal matrixing and DSP feat...

Page 15: ...sets are developed by TC Group product specialists to provide quick set up and optimum performance in a variety of common AV installations New users are advised to review all available factory presets...

Page 16: ...e to edit the text 14 5 2Configurationinblockdiagramview When a device is selected the corresponding Application parameters are shown in the Block Diagram view in the right hand column Click on the In...

Page 17: ...settings appropriate for many applications are available as presets using the scroll down menu under Presets below the Matrix box Level setting Select the desired matrix route framed in blue and use t...

Page 18: ...h 12 dB per octave slope Low Shelve 9 Shelving boost or cut with 9 dB per octave slope Low Shelve 6 Shelving boost or cut with 6 dB per octave slope Low Shelve 3 Shelving boost or cut with 3 dB per oc...

Page 19: ...cenario Close means that the GPI gets a voltage very close to zero GND and Open means that the voltage is close to Vcc thanks to an internal connection When Source Selector or Output Level functions a...

Page 20: ...p of the list in the left hand column IMPORTANT Do not close the main Application Browser window quit the program before saving an Application 14 6 2 Storingandsharingapplications or from this folder...

Page 21: ...n Online Mode any changes made to parameters in the Application Browser are transferred in real time to the connected LUCIA device A circular animation shows in the selected device while updating is i...

Page 22: ...lcontrolviaGPI Connectionandcomponents The default function for GPI is level control a linear potentiometer with a value between 1 k to 100 k ohm can be used As the GPI is internally pulled high it wi...

Page 23: ...d 100k ohm and one way to do it is as illustrated below this is also how the Lab gruppen accessory is made Selection and voltages for each of the selected positions is fully configurable Vcc GND GPI P...

Page 24: ...ere is what is known as the Active Power in the amplifier providing useful real world values of power consumption and heat dissipation LUCIA60 2M Level Load Output power Mains Watt 1 Thermal Dissipati...

Page 25: ...f power consumption and heat dissipation LUCIA120 2M Level Load Output power Mains voltage Line current Watt 1 Thermal Dissipation VAC IAC In Out Dissi pated BTU hr kCal hr Standby w remote Power Off...

Page 26: ...so the calculation Volts x Amps Watts would not be correct Instead measured and speci ed here is what is known as the Active Power in the ampli er providing useful real world values of power consumpti...

Page 27: ...is known as the Active Power in the ampli er providing useful real world values of power consumption and heat dissipation LUCIA240 2M Level Load Output power Mains voltage Line current Watt 1 Thermal...

Page 28: ...9 0 12 41 10 120 0 19 13 0 0 13 44 11 100 0 22 13 1 0 13 45 11 Pink pseudo noise 1 8 70 V 240 x 1 230 0 42 53 7 30 24 81 20 70 V 240 x 1 120 0 70 54 2 30 24 82 21 70 V 240 x 1 100 0 81 54 6 30 25 84 2...

Page 29: ...pins in a detachable screw terminal Default for gain GPO power state output 3 Contact closure type 2 pins in a detachable screw terminal Default for external monitoring of fault protection power off...

Page 30: ...oltage sense type 4 pins in a detachable screw terminal Default for gain GPO power state output 3 Contact closure type 2 pins in a detachable screw terminal Default for external monitoring of fault pr...

Page 31: ...0 Hz 80 Hz Level adjustment per input Front panel potentiometer detented from inf to 0 dB Matrix model features Inputs processing block 4 4 EQ sections per input Mix matrix routing block 4 2 in 1 out...

Page 32: ...LUCIA The latency through a LUCIA is 9 15 ms acoustically equivalent of 10 ft or 3 m This is primarily due to the look ahead limiters and to the multiband mastering compression used in our ADLC algori...

Page 33: ......

Page 34: ...o Load SenseTM are trademarks of Lab gruppen AB All other trademarks remain the property of their respective owners Copyright 2015 MUSIC Group Innovation Sweden AB All rights reserved labgruppen com I...

Reviews: