WEEE: Disposal at end of life. 

This equipment, when being disposed of in an EU Member State, is subject to the Waste Electrical and Electronic 

Equipment Regulations (WEEE) and must be recycled and disposed of in accordance with EU directive 2002/96/EC 

as applied in local laws of that State at the time of disposal. This refrigerator contains fl ammable insulation gases 

and must be disposed of in the appropriate way by competent persons. Ensure that none of the refrigerant circuit 

pipes are damaged prior to disposal.

The symbol below on the appliance or accompanying documents indicates that this refrigerator should not be 

treated as ordinary waste but must be taken to a special collection centre for the recycling of electrical equipment. 

For more information regarding the treatment, recovery or recycling of this product, contact your competent local 

offi  ce, electrical waste disposal or vendor from whom you purchased the refrigerator.

As this item is designed for medical or scientifi c use, before presenting for collection and disposal it will be 

necessary for the user to provide documentary evidence of decontamination and/or that it is entirely safe to handle 

and dismantle outside of a controlled environment. Goods that cannot be so certifi ed fall outside the scope of the 

Directive and remain the user’s responsibility to dispose of.

 

 

This refrigerator contains a fl ammable gas. 

It  MUST NOT be located in a room or area with a volume less than 10m

3

.

This refrigerator contains gas under pressure which may explode if heated.

Original instructions

 

WARNINGS

Servicing and repairs must be carried out by a suitably qualifi ed engineer. 

Only engineers who have been trained in the safe handling and use of  hydrocarbon 

refrigerants can work on the refrigeration system. If you suspect a leak, do not touch as 

the refrigerant can cause eye damage. Contact the manufacturer or its service agents 

immediately.

If the power supply cord is damaged, it MUST be replaced by the manufacturer, its 

service agent or similarly qualifi ed persons in order to avoid a hazard.

Do not use mechanical or other means to accelerate the defrosting process. 

Keep clear of obstruction all ventilation openings in the appliance enclosure. 

This refrigerator is climate class 4 and is designed to operate at +16°C to +32°C 

ambient room temperature.

Do not damage the refrigerant circuit.

Maximum shelf loading 40 Kg/m 

2

.

The noise level in normal operation is lower than 70 dB

Do not use electrical appliances inside the refrigerator.

Do not store explosive substances such as aerosol cans with fl ammable 

propellant in this appliance.

Labcold RLDF/G refrigerators are for the storing of pharmaceuticals, medicines and 

laboratory products for professional use by suitably trained, competent persons only.

Summary of Contents for IntelliCold

Page 1: ...www labcold com IntelliCold Pharmacy Refrigerator Operating Instructions...

Page 2: ...irective and remain the user s responsibility to dispose of This refrigerator contains a flammable gas It MUST NOT be located in a room or area with a volume less than 10m3 This refrigerator contains...

Page 3: ...14 Digital Door Lock 15 Caring for your fridge 18 Loading 18 Cleaning 19 Defrosting 19 Trouble Shooting 20 Useful Information 22 IMPORTANT These operating instructions contain information essential to...

Page 4: ...during manufacture and dry thoroughly Ensure your fridge is level by adjusting the feet at the bottom of your fridge For models RLDF G0501A 1010A and 1510A insert shelves by placing clips in the rack...

Page 5: ...ber on the display will descend accordingly ALTHOUGH THE REFRIGERATOR WILL REACH 5oC AFTER AN HOUR APPROX YOU SHOULD LEAVETHE FRIDGE RUNNING FOR 24 HOURS BEFORE FILLINGWITHTEMPERATURE SENSITIVEVACCINE...

Page 6: ...asons for this such as extremely cold items being placed in the fridge The cause of the drop in temperature should be investigated immediately and the refrigerator should be monitored to check that it...

Page 7: ...uter and or print hard copy The information stored in the controller will cover the last 13 months and is not deleted from the fridges memory when downloaded It is recommended you perform a download o...

Page 8: ...n you have the correct day The display will then change to allow you to set the time Firstly you need to set the hour by using the buttons on the right of the display Press the tick button when you ha...

Page 9: ...s all the temperature data copied to it since the timer was first set on the refrigerator or the last time the data was downloaded from the controller The Labcold SD card can now be inserted into a SD...

Page 10: ...ntinually displays the first two digits of the model number ie 02 with no decimal point or the display does not change to an alarm state or show a temperature value after a few minutes there is a syst...

Page 11: ...around LEDS Red Blue Place the battery terminals on the correct contact points PP3 Battery NOT included Opening the door Once the refrigerator has power you can now open the door using the factory set...

Page 12: ...ion is paid to the loading of the fridge and it is regularly cleaned and defrosted If you are storing vaccines in your IntelliCold pharmacy refrigerator this should be recorded in accordance with reco...

Page 13: ...vaccines If you press the set button on the front it will show the temperature the fridge is set to Should you wish to change the set point please contact the Labcold service team at service labcold...

Page 14: ...idge is questioned by an official body Labcold are a UKAS calibration laboratory No 8898 and are therefore capable of providing calibration to ISO 17025 standards Why not contact our service team at s...

Page 15: ...www labcold com...

Reviews: