Chapter 3: Getting Started
Product Service 1-800-522-7658
10
Original instructions
12" PVC Blowers feature a 12-3/8" OD inlet ring, which is suitable for use with
12-inch diameter PVC ductwork. The 12-inch diameter PVC ductwork will fit
over the inlet ring on the blower and should be fastened in position by sheet metal
screws into the fiberglass ring.
Connect the PVC Blower Drain
The PVC Blower has a 1/2" NPT drain connection in the bottom of the housing.
When this connection is used, it should be directed into a proper drain or into the
exhaust duct for proper disposal.
CAUTION: Draining the blower housing directly onto the roof may
cause damage to your roof due to the corrosive chemicals exhausted.
ATTENTION: Vidange du carter de la soufflante directement
sur le toit peut causer des dommages à votre toit en raison des
produits chimiques corrosifs épuisé.
Connect to the Blower Outlet
Before proceeding with the blower outlet connection, read the two warnings and
follow the suggested pictures listed next:
WARNING: Should your exhaust stack, on the outlet side of
the exhaust blower, extend over 7 feet, both guy wires and
additional structural supports are required to carry the weight
of this ductwork. The guy wires must be substantial enough to
support the exhaust stack against high wind velocities. See
photos on next page.
ATTENTION: Si votre cheminée d'échappement, sur le côté de
sortie du ventilateur d'évacuation, s'étendent sur 7 pieds, les
deux haubans et les supports structuraux supplémentaires sont
nécessaires pour supporter le poids de cette canalisation. Les
haubans doivent être suffisamment importants pour soutenir la
cheminée d'échappement contre la vitesse des vents élevés. Voir
les photos à la page suivante.
HINT: An exhaust damper either before or after the MSB
Blower is very useful for fine tuning the airflow.
PVC
!
!
Summary of Contents for 7061110
Page 36: ...Chapter 5 Using Your Blower Product Service 1 800 522 7658 32 Original instructions...
Page 48: ...Chapter 7 Modifying Your Blower Product Service 1 800 522 7658 44 Original instructions...
Page 58: ...Chapter 9 Troubleshooting Product Service 1 800 522 7658 54 Original instructions...
Page 62: ...Product Service 1 800 522 7658 58 APPENDIX B BLOWER DIMENSIONS...
Page 63: ...Appendix B Blower Dimensions Product Service 1 800 522 7658 59 Original instructions...
Page 64: ...Appendix B Blower Dimensions Product Service 1 800 522 7658 60 Original instructions...
Page 72: ...Product Service 1 800 522 7658 68 APPENDIX F TYPICAL PERCHLORIC ACID HOOD INSTALLATION DIAGRAM...